Initial scaffold: CLAUDE.md modules, directory structure, .gitignore
This commit is contained in:
127
CLAUDE.md
Normal file
127
CLAUDE.md
Normal file
@@ -0,0 +1,127 @@
|
||||
# Ignition + Docker Development Framework
|
||||
|
||||
## What This Is
|
||||
|
||||
Reusable scaffold for Ignition + Docker projects with Claude Code.
|
||||
The PLC I/O Testing Platform is the first project built on this framework.
|
||||
|
||||
## Stack
|
||||
|
||||
- Ignition 8.3 (Git-native project storage, Perspective, WebDev, OPC-UA)
|
||||
- Rockwell Allen-Bradley ControlLogix/CompactLogix, Studio 5000, PlantPAx
|
||||
- Docker Compose on Ubuntu 24 (Ignition, PostgreSQL, Traefik, Modbus sims)
|
||||
- Gitea at 192.168.3.59:3000 for source control
|
||||
- Jython 2.7 inside Ignition; Python 3.10+ for external tooling
|
||||
- Claude Code on the Linux host (VS Code Remote to Docker host)
|
||||
|
||||
## Language Rules
|
||||
|
||||
### Jython 2.7 (Inside Ignition)
|
||||
|
||||
All scripts in `ignition/project/` and gateway scripting run Jython 2.7.
|
||||
Hard constraints — violating these causes runtime errors:
|
||||
|
||||
- NO f-strings → use `"text {}".format(val)` or `"text %s" % val`
|
||||
- NO walrus operator `:=`
|
||||
- NO `pathlib` → use `os.path`
|
||||
- NO type hints → no `def foo(x: int) -> str:`
|
||||
- NO `dataclasses`, `enum.auto()`, `asyncio`
|
||||
- NO dictionary unpacking `{**d1, **d2}` → use `d1.update(d2)`
|
||||
- NO `yield from` → use explicit loops
|
||||
- Imports: `system.*` for Ignition API, standard Java/Jython libs only
|
||||
|
||||
### Python 3.10+ (External Tooling)
|
||||
|
||||
All scripts outside Ignition (test runners, utilities, CI/CD) use Python 3.10+.
|
||||
Comment the target environment at the top of every file:
|
||||
|
||||
```python
|
||||
# env: python3.10+ (external tooling — NOT Ignition)
|
||||
```
|
||||
|
||||
## Safety Rules (Non-Negotiable)
|
||||
|
||||
1. **Validate JSON** before writing to any Ignition resource directory.
|
||||
2. **Back up files** before overwriting: `cp file file.bak`
|
||||
3. **Sorted-key JSON** for all JSON files (Git-friendly diffs).
|
||||
4. **Never restart Ignition gateway** without explicit user confirmation.
|
||||
5. **Never `docker compose down`** without confirmation (destroys unnamed volumes).
|
||||
6. **Every change needs a verification step** — scenario run, curl, tag read.
|
||||
|
||||
## Canonical Patterns (Do Not Change Without Discussion)
|
||||
|
||||
### UDT / Linking Pattern
|
||||
|
||||
Linking/Link sub-UDT with `LinkPath` + `LinkData` for PLC signal binding.
|
||||
Decouples simulation from PLC I/O structure. All device test tags follow this.
|
||||
|
||||
### JSON Test Scenarios
|
||||
|
||||
Five required sections:
|
||||
- `identity` — scenario ID, version, description
|
||||
- `device` — device type, UDT path, tag references
|
||||
- `initial_state` — tag values to set before test begins
|
||||
- `sequence` — ordered steps with `delay_ms` between actions
|
||||
- `expected_outcomes` — pass/fail criteria with `tolerance`
|
||||
|
||||
See `testing/CLAUDE.md` for full schema.
|
||||
|
||||
### WebDev API
|
||||
|
||||
All external I/O goes through WebDev endpoints — never direct tag file edits at runtime:
|
||||
- `tagWrite` — write values to tags
|
||||
- `tagRead` — read tag values
|
||||
- `tagBrowse` — browse tag tree
|
||||
- `health` — gateway and connection status
|
||||
|
||||
See `webdev/CLAUDE.md` for endpoint contracts.
|
||||
|
||||
### Ignition as I/O Orchestrator
|
||||
|
||||
Ignition writes to Modbus containers and PLC I/O tags.
|
||||
PLC runs real logic. Test runner talks to Ignition only.
|
||||
Never bypass Ignition to write directly to Modbus or PLC.
|
||||
|
||||
## Directory Layout
|
||||
|
||||
```
|
||||
project-root/
|
||||
├── CLAUDE.md ← you are here
|
||||
├── docker/
|
||||
│ ├── CLAUDE.md ← Docker Compose patterns
|
||||
│ ├── docker-compose.yml
|
||||
│ ├── docker-compose.override.yml
|
||||
│ └── config/
|
||||
│ ├── ignition/
|
||||
│ ├── postgres/
|
||||
│ └── traefik/
|
||||
├── ignition/
|
||||
│ ├── CLAUDE.md ← Ignition project structure
|
||||
│ └── project/
|
||||
│ ├── com.inductiveautomation.perspective/
|
||||
│ ├── com.inductiveautomation.webdev/
|
||||
│ └── ignition/
|
||||
│ ├── named-query/
|
||||
│ ├── script-python/
|
||||
│ └── global-props/
|
||||
├── testing/
|
||||
│ ├── CLAUDE.md ← test scenario schema & runner
|
||||
│ ├── scenarios/
|
||||
│ ├── runner/
|
||||
│ └── results/
|
||||
├── webdev/
|
||||
│ ├── CLAUDE.md ← WebDev API contract
|
||||
│ └── endpoints/
|
||||
├── tools/
|
||||
│ └── (Python 3.10+ external utilities)
|
||||
└── docs/
|
||||
└── (project documentation)
|
||||
```
|
||||
|
||||
## Module CLAUDE.md Files
|
||||
|
||||
Each subdirectory has its own CLAUDE.md with domain-specific rules:
|
||||
- `docker/CLAUDE.md` — container orchestration, volumes, networking
|
||||
- `ignition/CLAUDE.md` — project structure, UDTs, scripting, resources
|
||||
- `testing/CLAUDE.md` — scenario schema, test runner, results format
|
||||
- `webdev/CLAUDE.md` — API endpoint contracts, request/response formats
|
||||
Reference in New Issue
Block a user