Modbus TCP (CSV Configuartion):

    1. Start Here!
        a. Go into the "spiffs" folder and open "device_config.ini"
        
        b. Under [wifi] you will enter the SSID (Name) of your wifi router
           and password.

        c. Setup the "static_ip" of the device, "gateway" of the network (router)
           and leave "netmask" as default (255.255.255.0).

        d. Under [modbus] leave port as default (502), leave max_clients as default (10)
           and modify "device_count" to the max amount of devices you want to simulate
           - Note: This will be based on the size of the modbus mapping you will use, the larger
                 the larger the mapping the more memory, the less devices you can simulate.
        
        e. Under [device 1], use this as a template to add devices, leave "enabled" as default (1),
           modify "unit_id", do not have duplicate IDs, "name" has to follow Deivce_x, "csv" will match the 
           csv file mapping you created or copied over.

    2. Creating CSV Files for Modbus TCP devices

        a. In the "spiffs" folder, there is a csv file called "Tempalte.csv"
            - Use this as reference on how to create your devices

        type,address,name,data_type,control_address,pics_address,pics_data_type,notes


        b. For Column "type" this will be the Modbus Register type
            - Coil
            - Discrete_Input
            - Input_Register
            - Holding_Register

        c. For Column "address", you will enter the modbus register , can be 5 digits or 6 digits
            - Coil: 00001 -> 09999 or 000001 -> 099999 
            - Discrete_Input: 10001 -> 19999 or 100001 -> 199999
            - Input_Register: 30001 -> 39999 or 300001 -> 399999
            - Holding_Register: 40001 -> 49999 or 400001 -> 499999

        d. For Column "name", enter the name of that point, can be whatever you want

        e. For Column "data_type", this will be the type of data the point represents
            - Coil: bool only
            - Discrete_Input: bool only
            - Input_Register: uint16, uint32, or float
            - Holding_Register: uint16, uint32, or float

        f. For Column "control_address", this is only for registers that are read only (inputs)
            - Create a counterpart of that input and type in the "address" of that point into "control_address"

            - For Example: Discrete_Input,10001,DI_1,bool,00001,,,,
                           Coil,00001,DI_1_Ovr,bool,,,,,

                            Input_Register,30001,AI_1,uint16,40001,,,,
                            Holding_Register,40001,AI_1_Ovr,uint16,,,,

        g. For Column "pics_address", this will be the address PICS uses to modify the data
            - You cannot use the modbus register (address) as PICS write the data in this fashion
            - Recommended default start is 410001
            - Also you do not need to add this address on Coil data types as it's 1 for 1
            - This is primarly needed for Holding_Register

            - PICS Data:
                - Boolean = sends data in 1 register
                - Integer = sends data in 2 registers
                - Float = sends data in 4 registers

        h. For Column "pics_data_type", the type of data pics is sending to that modbus register
            - Look at g. for the PICS Data.

        i. For Column "notes", enter notes to help you understand the purpose of that modbus register

    3. Increasing Modbus MAX Points

        a. Once you complete your device csv file, head to "main" -> "modbus_points.h"

        b. At the very top of the file, find "#define MODBUS_MAX_POINTS"
            - Modify this value based on the maximum registers needed for your device
        
    4. Starting Modbus TCP Device

        a. Once you complete setting up the device, you are ready to flash the device

        b. Download ESP32 IDF from Espressif Systems
            Link: https://docs.espressif.com/projects/esp-idf/en/stable/esp32/get-started/windows-setup.html

            Install the EIM, follow the easy installation

        c. Once in the dashboard, click on open IDF terminal

        d. Run these commands:
            - cd "Location the program is stored at"
            - idf.py fullclean
            - idf.py build
            - idf.py -p COM# flash monitor (COM# is the COM port number, look in Device Manager -> Ports)
        
    5. Verify with Modscan32