First stable compilation with ModbusRTU and ModbusTCP
This commit is contained in:
148
lib/modbus-esp8266/ModbusSettings.h
Normal file
148
lib/modbus-esp8266/ModbusSettings.h
Normal file
@@ -0,0 +1,148 @@
|
||||
|
||||
/*
|
||||
Modbus Library for Arduino
|
||||
|
||||
Copyright (C) 2019-2022 Alexander Emelianov (a.m.emelianov@gmail.com)
|
||||
https://github.com/emelianov/modbus-esp8266
|
||||
This code is licensed under the BSD New License. See LICENSE.txt for more info.
|
||||
|
||||
Prefixes:
|
||||
MODBUS_ Global library settings
|
||||
MODBUSIP_ Settings for TCP and TLS both
|
||||
MODBUSTCP_ Settings for TCP
|
||||
MODBUSTLS_ Settings for TLS
|
||||
MODBUSRTU_ Settings for RTU
|
||||
MODBUSAPI_ Settings for API
|
||||
*/
|
||||
#pragma once
|
||||
|
||||
/*
|
||||
#define MODBUS_GLOBAL_REGS
|
||||
If defined Modbus registers will be shared across all Modbus* instances.
|
||||
If not defined each Modbus object will have own registers set.
|
||||
*/
|
||||
#define MODBUS_GLOBAL_REGS
|
||||
//#define MODBUS_FREE_REGS
|
||||
|
||||
/*
|
||||
#define ARDUINO_SAM_DUE_STL
|
||||
Use STL with Arduino Due. Was able to use with Arduino IDE but not with PlatformIO
|
||||
Also note STL issue workaround code in Modbus.cpp
|
||||
*/
|
||||
#if defined(ARDUINO_SAM_DUE)
|
||||
//#define ARDUINO_SAM_DUE_STL
|
||||
#endif
|
||||
|
||||
/*
|
||||
#define MODBUS_USE_STL
|
||||
If defined C STL will be used.
|
||||
*/
|
||||
#if defined(ESP8266) || defined(ESP32) || defined(ARDUINO_ARCH_STM32) || defined(ARDUINO_SAM_DUE_STL)
|
||||
#define MODBUS_USE_STL
|
||||
#endif
|
||||
|
||||
/*
|
||||
#define MODBUS_MAX_REGS 32
|
||||
If defined regisers count will be limited.
|
||||
*/
|
||||
// Add limitation for specific STL implementation
|
||||
#if defined(MODBUS_USE_STL) && (defined(ESP8266) || defined(ESP32))
|
||||
#undef MODBUS_MAX_REGS
|
||||
#define MODBUS_MAX_REGS 4000
|
||||
#endif
|
||||
|
||||
#define MODBUS_ADD_REG
|
||||
//#define MODBUS_STRICT_REG
|
||||
#define MODBUS_MAX_FRAME 256
|
||||
//#define MODBUS_STATIC_FRAME
|
||||
#define MODBUS_MAX_WORDS 0x007D
|
||||
#define MODBUS_MAX_BITS 0x07D0
|
||||
#define MODBUS_FILES
|
||||
#define MODBUS_MAX_FILES 0x270F
|
||||
#define MODBUSTCP_PORT 502
|
||||
#define MODBUSTLS_PORT 802
|
||||
#define MODBUSIP_MINFRAME 2
|
||||
#define MODBUSIP_MAXFRAME 200
|
||||
|
||||
/*
|
||||
ModbusTCP and ModbusTLS timeouts
|
||||
#define MODBUSIP_TIMEOUT 1000
|
||||
Outgoing request timeout
|
||||
#define MODBUSIP_CONNECT_TIMEOUT 1000
|
||||
ESP32 only. Outgoing connection attempt timeout
|
||||
*/
|
||||
#define MODBUSIP_TIMEOUT 1000
|
||||
//#define MODBUSIP_CONNECT_TIMEOUT 1000
|
||||
|
||||
#define MODBUSIP_UNIT 255
|
||||
#define MODBUSIP_MAX_TRANSACTIONS 16
|
||||
#if defined(ESP32)
|
||||
#define MODBUSIP_MAX_CLIENTS 8
|
||||
#else
|
||||
#define MODBUSIP_MAX_CLIENTS 4
|
||||
#endif
|
||||
#define MODBUSIP_UNIQUE_CLIENTS
|
||||
#define MODBUSIP_MAX_READMS 100
|
||||
|
||||
/*
|
||||
Use available() instead of accept() to get TCP client
|
||||
#define MODBUSIP_USE_AVAILABLE
|
||||
Used to wrap variation in Ethernet/WiFi client API implementations
|
||||
*/
|
||||
//#define MODBUSIP_USE_AVAILABLE
|
||||
|
||||
#define MODBUSIP_FULL
|
||||
//#define MODBUSIP_DEBUG
|
||||
/*
|
||||
Allows to use DNS names as target
|
||||
Otherwise IP addresses only must be used
|
||||
#define MODBUS_IP_USE_DNS
|
||||
*/
|
||||
//#define MODBUS_IP_USE_DNS
|
||||
|
||||
//#define MODBUSRTU_DEBUG
|
||||
#define MODBUSRTU_BROADCAST 0
|
||||
#define MB_RESERVE 248
|
||||
#define MB_SERIAL_BUFFER 128
|
||||
#ifndef MODBUSRTU_TIMEOUT
|
||||
#define MODBUSRTU_TIMEOUT 1000
|
||||
#endif
|
||||
#define MODBUSRTU_MAX_READMS 100
|
||||
/*
|
||||
#define MODBUSRTU_REDE
|
||||
Enable using separate pins for RE DE
|
||||
*/
|
||||
//#define MODBUSRTU_REDE
|
||||
|
||||
// Define for internal use. Do not change.
|
||||
#define MODBUSRTU_TIMEOUT_US 1000UL * MODBUSRTU_TIMEOUT
|
||||
#define MODBUSRTU_MAX_READ_US 1000UL * MODBUSRTU_MAX_READMS
|
||||
|
||||
/*
|
||||
#defone MODBUSRTU_FLUSH_DELAY 1
|
||||
Set extraa delay after serial buffer flush before changing RE/DE pin state.
|
||||
Specified in chars. That is 1 is means to add delay enough to send 1 char at current port baudrate
|
||||
*/
|
||||
//#define MODBUSRTU_FLUSH_DELAY 1
|
||||
|
||||
#define MODBUSRTU_REDE_SWITCH_US 1000
|
||||
|
||||
#define MODBUSAPI_LEGACY
|
||||
#define MODBUSAPI_OPTIONAL
|
||||
|
||||
// Workaround for RP2040 flush() bug
|
||||
#if defined(ARDUINO_ARCH_RP2040)
|
||||
#define MODBUSRTU_FLUSH_DELAY 1
|
||||
#endif
|
||||
|
||||
// Limit resources usage for entry level boards
|
||||
#if defined(ARDUINO_UNO) || defined(ARDUINO_LEONARDO)
|
||||
#undef MODBUS_MAX_REGS
|
||||
#undef MODBUSIP_MAX_TRANSACTIONS
|
||||
#undef MODBUS_MAX_WORDS
|
||||
#undef MODBUS_MAX_BITS
|
||||
#define MODBUS_MAX_REGS 32
|
||||
#define MODBUSIP_MAX_TRANSACTIONS 4
|
||||
#define MODBUS_MAX_WORDS 0x0020
|
||||
#define MODBUS_MAX_BITS 0x0200
|
||||
#endif
|
||||