Parameters for PI_B function block
Reserved for autotuning
Lower limit of the process value range
Upper limit of the process value range
Lower limit of the output value range
Upper limit of the output value range
0: direct action of the PID controller 1: opposite action of the PID controller
1: the RCPY input is used
Proportional contribution (gain)
Integral time
Dead zone on deviation
Manual adjustment of static deviation
Analog input value
Forced value
Force command
Forced state
Physical value
Function type
Channel health
Channel warning
Measurement status word
Aligned channel
Measurement within lower tolerance zone
Measurement within upper tolerance zone
Internal offset error
Internal reference error
Power supply error
SPI communication error
Module health
Module faults
Module health
Module faults
Module health
Module faults
Analog output value
Forced Value
Force command
Forced state
Physical value
Function type
Channel health
Module health
Module faults
Module health
Module faults
Module health
Module faults
Channel health
Discrete input value
Module health
Module faults
Module health
Module faults
Module health
Module faults
Module health
Module faults
Channel health
Discrete output value
Module health
Module faults
Module health
Module faults
Module health
Module faults
Module health
Module faults
Channel error
Discrete input value
Common array for communication EF Mid-Range
Common array for EIO communication function blocks
Common array for communication EF
Datatype extended for master control block MSTR_CTL
operation code
error status
number of data units transferred
operation-dependent information
routing address
operation-dependent information
Data structure for the XMIT configuration
Data Rate
Data bits
Parity
Stop bits
Command word
Message Length
Retry limit
Start of transmission delay (ms)
End of transmission delay (ms)
Response time-out (ms)
Health bits of rack 0: slots 0 to 15
Health bits of rack 1: slots 0 to 15
Device name of the CRA drop
Firmware version of the CRA
Rotary switches value at power up
State of the CRA module
CRA diagnostic information
At least one IO error in drop when 0
CCOTF in progress
CCOTF error
IOPL mismatch
Rotary switches have changed since last power up
Drop communication health
Redundant power supply status
Execution time of the last CRA cycle (unit: 0.01 ms)
Longes CRA cycle execution time (unit: 0.01 ms)
Shortest CRA cycle execution time (uint: 0.01 ms)
Number of time stamp records available in the drop local buffer
Diagnostic information about the source time stamped events service
Time valid and synchronized
Clock failure
Clock not synchronized
Buffer full
Percentage of the buffer filled [0..100]
Main state of the TS events service
Ethernet status
Link up/down for Ethernet port 1
Link up/down for Ethernet port 2
Link up/down for Ethernet port 3
Link up/down for Ethernet backplane port
Ethernet/IP RPI change in progress
Redundant owner is present
0: one or more services not operating normally / 1: all operational
One bit for each user-observable feature
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
Ethernet backplane status (0: failure, 1: OK)
Ethernet backplane error (0: error, 1: OK)
Ethernet port status
Time elapsed since last update from NTP server (unit: 100 ms)
Max packet interval for output packets (unit: 1 ms)
Number of bytes received on interface
Numberof inbound packets that contain errors
Number of bytes sent on interface
Number of outbound packets that contain errors
SOE uncertain (in timestamping system only)
Ethernet status
Link up/down for Ethernet port 1
Link up/down for Ethernet port 2
Link up/down for Ethernet port 3
Link up/down for Ethernet backplane port
Scanner OK and scanning at least 1 equipment (if at least 1 equipment configured)
0: one or more services not operating normally / 1: all operational
1: No traffic overload detected / 0: Traffic overload detected
One bit for each user-observable feature
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
Main IP address status (0 in caes of duplicate IP or no IP assigned)
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
One bit for each user-observable feature
LLDP service status
0: event log service not operating normally / 1: event log service operating normally
1: No acknowledgement received from the syslog server / 0: otherwise
Ethernet port 1 and 2 status
Ethernet port 3 and backplane port status
MSB=Major revision, LSB=Minor revision
% of FDR server usage
Number of packets received on interface
Number of inbound packets that contain errors
Number of packets sent on interface
Number of outbound packets that contain errors
Signature of all files on local module FDR server
Local Slave health bits (local slave 1 to 16)
DIO health bits (1 bit per DIO up to 128 DIOs. 112-127 are reserved for future extension)
DIO control bits (1 bit per DIO up to 128 DIOs. 112-127 are reserved for future extension)
Status of the remote PLC
Applications of the primary and the standby are different from the origin
Command that allows logic mismatch between the primary and the standby
Applications of the primary and the standby are running with different step of online modification
Applications of the primary and the standby are running with difference at least one SFC section
Applications of the primary and the standby are running with different steps of offline modification
Number of differences between the application of the primary and application of the secondary
Number maximum of differences allowed between application of the primary and the application of the secondary
Command that allows firmware mismatch between the primary and the standby
Firmware of the primary is different from the firmware of the standby
Data layout of the primary is different from the data layout of the standby
Amount of data in KByte sent by the primary and discarded by the standby
Amount of data in KByte not updated by the standby (rounded to the upper)
Backup application of the primary and backup application fo the standby
Command that allows PLC A to go promary or standby (modification allowed only on primary)
Command that allows PLC B to go primary or standby (modification allowed only on primary)
Swap primary and standby command (modification allowed only on primary)
Transfer application from the primary to the standby command (modification allowed only on primary)
Command that automatically start the application in Run after transfer (modification allowed only on primary)
Run remote controller command (modification allowed only on primary)
Stop remote controller command (modification allowed on primary, on stop or on wait)
Command that start a comparison of the variable initial values (modification allowed only on primary)
Initial values comparision status
Exchanged data from the last MAST cycle standby receipt status
Exchanged data from the last FAST cycle standby receipt status
Exchanged data from the last SAFE cycle standby receipt status
Hot standby link error (no heartbeat connection on hot standby link)
Hot standby supplementary link error (no heartbeat connection on supplementary link)
The PLC is in Run but is waiting to be part of the hot standby system
The PLC is in Run Primary state
The PLC is in Run Standby state
The PLC is in Stop
The PLC switch is on A position
The PLC switch is on B position
The PLC does not see any of the configured EIO drops
An SD Card is inserted
True: the local rack is OK / False: the local rack is not ok (module missing)
Free space to exchange information between primary and standby PLCs.