First Scan Bit
System Time
PLC Cold Start
PLC Warm Start
CPU Error
Use Simulation Logic for point mapping
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
RWPS West Intake Valve High Torque
RWPS West Suction Bypass Mode Enabled
RWPS West Suction Low Pressure Lockout
Spare
RWPS West Suction Valve High Torque
Spare
Spare
Spare
RWPS East Intake Valve High Torque
RWPS East Suction Bypass Mode Enabled
RWPS East Suction Low Pressure Lockout
Spare
RWPS East Suction Valve High Torque
RWPS To Reservoir West Suction Valve High Torque
RWPS To Reservoir West Sleeve Valve High Torque
RWPS To Reservoir West Discharge Valve High Torque
Spare
RWPS To Reservoir East Suction Valve High Torque
RWPS To Reservoir East Sleeve Valve High Torque
RWPS To Reservoir East Discharge Valve High Torque
RWPS Pump 1 Speed
RWPS Motor 1 X-Direction Vibration Drive End Bearing
RWPS Pump 1 Discharge Pressure
RWPS Pump 1 Cooling Water Flow
RWPS West Suction Pressure
RWPS Scada Room Ambient Temperature
RWPS Reservoir Valve West Side Position Indication
RWPS Pump 1 In Bypass Mode
RWPS Pump 1 Discharge Pressure Bypass Mode
RWPS Pump 1 Cooling Water Flow Failure
RWPS Pump 1 E. Stop
RWPS Pump 1 MPR Alarm
RWPS Pump 1 High Rtd Temp
RWPS Pump 1 MPR Trip
RWPS Pump 1 Trip
RWPS Pump 1 E. Stop
RWPS Pump 1 Bypass Mode Enabled
RWPS Pump 1 Isolation Valve Bypass Mode
RWPS Pump 1 Suction Pressure Loss
RWPS Pump 1 PFCC Online
RWPS Pump 1 Suction Valve High Torque
RWPS Pump 1 Control Valve Failure
RWPS Pump 1 Discharge Valve High Torque
Spare
RWPS Pump 2 In Bypass Mode
RWPS Pump 2 Discharge Pressure Bypass Mode
RWPS Pump 2 Cooling Water Flow Failure
RWPS Pump 2 E. Stop
RWPS Pump 2 MPR Alarm
RWPS Pump 2 High Rtd Temp
RWPS Pump 2 MPR Trip
RWPS Pump 2 Trip
RWPS Pump 2 E. Stop
RWPS Pump 2 Bypass Mode Enabled
RWPS Pump 2 Isolation Valve Bypass Mode
RWPS Pump 2 Suction Pressure Loss
RWPS Pump 2 Suction Valve High Torque
RWPS Pump 2 Discharge Valve High Torque
Spare
RWPS Pump 9 In Bypass Mode
RWPS Pump 9 Discharge Pressure Bypass Mode
RWPS Pump 9 Cooling Water Flow Failure
RWPS Pump 9 E. Stop
RWPS Pump 9 MPR Alarm
RWPS Pump 9 High Rtd Temp
RWPS Pump 9 MPR Trip
RWPS Pump 9 Trip
RWPS Pump 9 E. Stop
RWPS Pump 9 Bypass Mode Enabled
RWPS Pump 9 Isolation Valve Bypass Mode
RWPS Pump 3 Suction Pressure Loss
RWPS Pump 9 PFCC Online
RWPS Pump 9 Suction Valve High Torque
RWPS Pump 9 Discharge Valve High Torque
Spare
RWPS Stand-By Generator Low Fuel
RWPS Stand-By Generator Low Oil Pressure
RWPS Stand-By Generator Over Speed
RWPS Stand-By Generator Battery Sys Malfunction
Spare
RWPS 480V Switchgear Common Alarm
RWPS AFD Pump 2 Speed
RWPS Motor 2 X-Direction Vibration Drive End Bearing
RWPS Pump 2 Discharge Pressure
RWPS Pump 2 X-Direction Vibration (Ce)
RWPS Pump 2 Cooling Water Flow
RWPS East Suction Pressure
RWPS Electrical Room Ambient Temperature
RWPS Reservoir Valve East Side Position Indication
RWPS Pump 1 Speed Setpoint
RWPS Reservoir Valve West Side Position Setpoint
RWPS Pump 9 Speed Setpoint
RWPS Northwest Sump Pump Fault
RWPS Northwest Sump Pump Control Power Failure
RWPS Southwest By Pump 1 Sump Pump Fault
RWPS Southwest By Pump 1 Sump Pump Control Power Failure
RWPS Southwest By Pump 4 Sump Pump Fault
RWPS Southwest By Pump 4 Sump Pump Control Power Failure
RWPS West Alcove Sump Pump Fault
RWPS East Elevator Sump Pump Control Power Failure
RWPS Northeast Sump Pump Fault
RWPS Northeast Sump Pump Control Power Failure
RWPS Southeast Sump Pump Fault
RWPS Southeast Sump Pump Control Power Failure
RWPS East Alcove Sump Pump Fault
RWPS East Alcove Sump Pump Control Power Failure
RWPS West Elevator Sump Pump Fault
RWPS West Elevator Sump Pump Control Power Failure
Spare
Spare
Spare
Spare
RWPS East Elevator Sump Pump Fault
Spare
Spare
Spare
RWPS West Secondary Dewatering Pump A Fault
RWPS West Secondary Dewatering SSRVS A Fault
RWPS West Secondary Dewatering Control Power Failure
RWPS West Secondary Dewatering High Level Alarm
RWPS West Secondary Dewatering Pump B Fault
RWPS West Secondary Dewatering SSRVSB Fault
RWPS Intake Maintenance Dewatering Pump Fault
Spare
Spare
RWPS East Secondary Dewatering Pump C Fault
RWPS East Secondary Dewatering SSRVSC Fault
RWPS East Secondary Dewatering Control Power Failure
RWPS East Secondary Dewatering High Level Alarm
RWPS East Secondary Dewatering Pump D Fault
RWPS East Secondary Dewatering SSRVSD Fault
RWPS Discharge Maintenance Dewatering Pump Fault
Spare
RWPS West Dam Collector Pump A Fault
RWPS West Dam Collector Pump B Fault
RWPS West Dam Collector Pump Control Power Failure
RWPS West Dam Collector Wet Well High Level Alarm
RWPS West Dam Collector Wet Well High-High Level Alarm
RWPS Substation Transformer 3 Low Oil Level
RWPS Substation Transformer 3 Pressure Relief Device Activation
RWPS Substation Transformer 5 Low Oil Level
RWPS Substation Transformer 5 Pressure Relief Device Activation
RWPS East Dam Collector Pump A Fault
RWPS East Dam Collector Pump B Fault
RWPS East Dam Collector Pump Control Power Failure
RWPS East Dam Collector Wet Well High Level Alarm
RWPS East Dam Collector Wet Well High-High Level Alarm
RWPS Substation Transformer 4 Low Oil Level
RWPS Substation Transformer 4 Pressure Relief Device Activation
RWPS Substation Transformer 6 Low Oil Level
RWPS Substation Transformer 6 Pressure Relief Device Activation
Spare
Spare
RWPS Pump 9 Speed
RWPS Motor 9 X-Direction Vibration Drive End Bearing
RWPS Pump 9 Discharge Pressure
RWPS Pump 9 X-Direction Vibration (Ce)
RWPS Pump 9 Cooling Water Flow
RWPS Discharge Pressure
RWPS Reservoir Release Flow
RWPS Pump 2 Speed Setpoint
RWPS Reservoir Valve East Side Position Setpoint
RWPS West Pump Room Bypass Enabled
RWPS West Pump Room High Level Alarm
RWPS West Pump Hatch Open
RWPS West Alcove Hatch Open
RWPS West Elevator Common Alarm
RWPS West Stairwell Smoke Detected
Spare
RWPS SWB-0112-1 SPD Maintenance Alarm
RWPS SWG-0112-3A SPD Maintenance Alarm
RWPS PP-0112-1 SPD Maintenance Alarm
RWPS LP-0112-1 SPD Maintenance Alarm
RWPS PP-0113-1 SPD Maintenance Alarm
Spare
RWPS East Pump Room Bypass Enabled
RWPS East Pump Room High Level Alarm
RWPS East Pump Hatch Open
RWPS East Alcove Hatch Open
RWPS East Elevator Common Alarm
RWPS East Stairwell Smoke Detected
Spare
RWPS SWB-0112-2 SPD Maintenance Alarm
RWPS SWG-0112-3B SPD Maintenance Alarm
RWPS PP-0112-2 SPD Maintenance Alarm
Spare
RWPS PP-0113-2 SPD Maintenance Alarm
Spare
RWPS Recloser 3 Trip
RWPS Plc Panel DC Power Ok
RWPS Plc Panel Door Open
RWPS Net Panel DC Power Ok
RWPS Net Panel Door Open
RWPS Scada UPS Panel Door Open
RWPS Scada UPS Panel UPS Alarm
RWPS Security UPS Panel Door Open
RWPS Security UPS Panel UPS Alarm
Spare
Spare
Spare
RWPS Recloser 4 Trip
RWPS Electrical Building Intrusion
RWPS Elevator Pit Common High Level Alarm
RWPS Flow To Reservoir 1000 Gal Pulse
Spare
Spare
Spare
Spare
Spare
Spare
RWPS West Pump Room Smoke Alarm
RWPS East Pump Room Smoke Alarm
Spare
Spare
Spare
RWPS Switchgear 0112-2 Common Alarm
RWPS Switchgear 0112-2 Main "A2" Closed Status
RWPS Switchgear 0112-2 "A2" Power Available
RWPS Switchgear 0112-2 Main "B2" Closed Status
RWPS Switchgear 0112-2 "B2" Power Available
RWPS Switchgear 0112-2 Main "G2" Closed Status
RWPS Switchgear 0112-2 "G2" Power Available
RWPS Switchgear 0112-2 Tie "No. 2" Open Status
RWPS Switchgear 0112-2 Transfer Failure
Active Harmonic Filter Common Alarm
Active Harmonic Filter Power On
RWPS Switchgear 0112-2 Main "A2" Closed Status
RWPS Switchgear 0112-2 Main "G2" Closed Status
Spare
Spare
Spare
Spare - RWPS Pump 7 AFD Bypass Starter
Spare
RWPS Pump 8 Discharge Pressure
RWPS Pump 8 Cooling Water Flow
RWPS Pump 8 Control Valve Position Indication
RWPS Motor 8 X-Direction Vibration Drive End Bearing
RWPS Motor 8 Y-Direction Vibration Drive End Bearing
RWPS Motor 8 X-Direction Vibration Non-Drive End Bearing
RWPS Motor 8 Y-Direction Vibration Non-Drive End Bearing
RWPS West Intake Valve Remote Enabled Channel Fault
RWPS West Intake Valve Local Enabled Channel Fault
RWPS West Intake Valve Open Status Channel Fault
RWPS West Intake Valve Closed Status Channel Fault
RWPS West Intake Valve High Torque Channel Fault
RWPS West Suction Bypass Mode Enabled Channel Fault
RWPS West Suction Low Pressure Lockout Channel Fault
Spare
RWPS West Suction Valve Remote Enabled Channel Fault
RWPS West Suction Valve Local Enabled Channel Fault
RWPS West Suction Valve Open Status Channel Fault
RWPS West Suction Valve Closed Status Channel Fault
RWPS West Suction Valve High Torque Channel Fault
RWPS Pump 1 PCV Panel Not Ready/Fail Alarm Channel Fault
Pump 2 PCV Panel Not Ready/Fail Alarm Channel Fault
Pump 9 PCV Panel Not Ready/Fail Alarm Channel Fault
RWPS East Intake Valve Remote Enabled Channel Fault
RWPS East Intake Valve Local Enabled Channel Fault
RWPS East Intake Valve Open Status Channel Fault
RWPS East Intake Valve Closed Status Channel Fault
RWPS East Intake Valve High Torque Channel Fault
RWPS East Suction Bypass Mode Enabled Channel Fault
RWPS East Suction Low Pressure Lockout Channel Fault
RWPS East Suction Valve Remote Enabled Channel Fault
RWPS East Suction Valve Local Enabled Channel Fault
RWPS East Suction Valve Open Status Channel Fault
RWPS East Suction Valve Closed Status Channel Fault
RWPS East Suction Valve High Torque Channel Fault
RWPS To Reservoir West Suction Valve Local Enabled Channel Fault
RWPS To Reservoir West Suction Valve Remote Enabled Channel Fault
RWPS To Reservoir West Suction Valve Open Status Channel Fault
RWPS To Reservoir West Suction Valve Closed Status Channel Fault
RWPS To Reservoir West Suction Valve High Torque Channel Fault
RWPS To Reservoir West Sleeve Valve Local Enabled Channel Fault
RWPS To Reservoir West Sleeve Valve Remote Enabled Channel Fault
RWPS To Reservoir West Sleeve Valve Open Status Channel Fault
RWPS To Reservoir West Sleeve Valve Closed Status Channel Fault
RWPS To Reservoir West Sleeve Valve High Torque Channel Fault
RWPS To Reservoir West Discharge Valve Local Enabled Channel Fault
RWPS To Reservoir West Discharge Valve Remote Enabled Channel Fault
RWPS To Reservoir West Discharge Valve Open Status Channel Fault
RWPS To Reservoir West Discharge Valve Closed Status Channel Fault
RWPS To Reservoir West Discharge Valve High Torque Channel Fault
Spare
RWPS To Reservoir East Suction Valve Local Enabled Channel Fault
RWPS To Reservoir East Suction Valve Remote Enabled Channel Fault
RWPS To Reservoir East Suction Valve Open Status Channel Fault
RWPS To Reservoir East Suction Valve Closed Status Channel Fault
RWPS To Reservoir East Suction Valve High Torque Channel Fault
RWPS To Reservoir East Sleeve Valve Local Enabled Channel Fault
RWPS To Reservoir East Sleeve Valve Remote Enabled Channel Fault
RWPS To Reservoir East Sleeve Valve Open Status Channel Fault
RWPS To Reservoir East Sleeve Valve Closed Status Channel Fault
RWPS To Reservoir East Sleeve Valve High Torque Channel Fault
RWPS To Reservoir East Discharge Valve Local Enabled Channel Fault
RWPS To Reservoir East Discharge Valve Remote Enabled Channel Fault
RWPS To Reservoir East Discharge Valve Open Status Channel Fault
RWPS To Reservoir East Discharge Valve Closed Status Channel Fault
RWPS To Reservoir East Discharge Valve High Torque Channel Fault
Spare
RWPS Pump 1 Suction Valve Open Command Channel Fault
RWPS Pump 1 Suction Valve Close Command Channel Fault
RWPS Pump 1 Discharge Valve Open Command Channel Fault
RWPS Pump 1 Discharge Valve Close Command Channel Fault
RWPS Pump 1 Scada Start Channel Fault
RWPS Pump 1 Scada Stop Channel Fault
RWPS Pump 1 Scada Lockout Channel Fault
RWPS Pump 1 Bypass Mode Command Channel Fault
RWPS West Intake Valve Open Command Channel Fault
RWPS West Intake Valve Close Command Channel Fault
RWPS West Suction Valve Open Command Channel Fault
RWPS West Suction Valve Close Command Channel Fault
MV Switchgear PFCC 1 Inhibit Signal (PCO-48) Channel Fault
MV Switchgear PFCC 2 Inhibit Signal (PCO-48) Channel Fault
Spare
RWPS Pump 1 Speed Channel Fault
RWPS Motor 1 X-Direction Vibration Drive End Bearing Channel Fault
RWPS Pump 1 Discharge Pressure Channel Fault
RWPS Pump 1 Cooling Water Flow Channel Fault
RWPS West Suction Pressure Channel Fault
RWPS Scada Room Ambient Temperature Channel Fault
RWPS Reservoir Valve West Side Position Indication Channel Fault
RWPS Pump 1 In Bypass Mode Channel Fault
RWPS Pump 1 Discharge Pressure Bypass Mode Channel Fault
RWPS Pump 1 Cooling Water Flow Failure Channel Fault
RWPS Pump 1 Scada Enabled Channel Fault
RWPS Pump 1 Ready Channel Fault
RWPS Pump 1 Run Status Channel Fault
RWPS Pump 1 E. Stop Channel Fault
RWPS Pump 1 MPR Alarm Channel Fault
RWPS Pump 1 High Rtd Temp Channel Fault
RWPS Pump 1 MPR Trip Channel Fault
RWPS Pump 1 Trip Channel Fault
RWPS Pump 1 E. Stop Channel Fault
RWPS Pump 1 Bypass Mode Enabled Channel Fault
RWPS Pump 1 Isolation Valve Bypass Mode Channel Fault
RWPS Pump 1 Suction Pressure Loss Channel Fault
RWPS Pump 1 PFCC Online Channel Fault
RWPS Pump 1 Suction Valve Remote Enabled Channel Fault
RWPS Pump 1 Suction Valve Local Enabled Channel Fault
RWPS Pump 1 Suction Valve High Torque Channel Fault
RWPS Pump 1 Suction Valve Open Status Channel Fault
RWPS Pump 1 Suction Valve Closed Status Channel Fault
RWPS Pump 1 Control Valve Maint. Mode Channel Fault
RWPS Pump 1 Control Valve Failure Channel Fault
RWPS Pump 1 Control Valve Open Status Channel Fault
RWPS Pump 1 Control Valve Closed Status Channel Fault
RWPS Pump 1 Discharge Valve Remote Enabled Channel Fault
RWPS Pump 1 Discharge Valve Local Enabled Channel Fault
RWPS Pump 1 Discharge Valve High Torque Channel Fault
RWPS Pump 1 Discharge Valve Open Status Channel Fault
RWPS Pump 1 Discharge Valve Closed Status Channel Fault
Spare
RWPS Pump 2 In Bypass Mode Channel Fault
RWPS Pump 2 Discharge Pressure Bypass Mode Channel Fault
RWPS Pump 2 Cooling Water Flow Failure Channel Fault
RWPS Pump 2 Scada Enabled Channel Fault
RWPS Pump 2 Ready Channel Fault
RWPS Pump 2 Run Status Channel Fault
RWPS Pump 2 E. Stop Channel Fault
RWPS Pump 2 MPR Alarm Channel Fault
RWPS Pump 2 High Rtd Temp Channel Fault
RWPS Pump 2 MPR Trip Channel Fault
RWPS Pump 2 Trip Channel Fault
RWPS Pump 2 E. Stop Channel Fault
RWPS Pump 2 Bypass Mode Enabled Channel Fault
RWPS Pump 2 Isolation Valve Bypass Mode Channel Fault
RWPS Pump 2 Suction Pressure Loss Channel Fault
RWPS Pump 2 PFCC Online Channel Fault
RWPS Pump 2 Suction Valve Remote Enabled Channel Fault
RWPS Pump 2 Suction Valve Local Enabled Channel Fault
RWPS Pump 2 Suction Valve High Torque Channel Fault
RWPS Pump 2 Suction Valve Open Status Channel Fault
RWPS Pump 2 Suction Valve Closed Status Channel Fault
RWPS Pump 2 Control Valve Maint. Mode Channel Fault
RWPS Pump 2 Control Valve Failure Channel Fault
RWPS Pump 2 Control Valve Open Status Channel Fault
RWPS Pump 2 Control Valve Closed Status Channel Fault
RWPS Pump 2 Discharge Valve Remote Enabled Channel Fault
RWPS Pump 2 Discharge Valve Local Enabled Channel Fault
RWPS Pump 2 Discharge Valve High Torque Channel Fault
RWPS Pump 2 Discharge Valve Open Status Channel Fault
RWPS Pump 2 Discharge Valve Closed Status Channel Fault
Spare
RWPS Pump 9 In Bypass Mode Channel Fault
RWPS Pump 9 Discharge Pressure Bypass Mode Channel Fault
RWPS Pump 9 Cooling Water Flow Failure Channel Fault
RWPS Pump 9 Scada Enabled Channel Fault
RWPS Pump 9 Ready Channel Fault
RWPS Pump 9 Run Status Channel Fault
RWPS Pump 9 E. Stop Channel Fault
RWPS Pump 9 MPR Alarm Channel Fault
RWPS Pump 9 High Rtd Temp Channel Fault
RWPS Pump 9 MPR Trip Channel Fault
RWPS Pump 9 Trip Channel Fault
RWPS Pump 9 E. Stop Channel Fault
RWPS Pump 9 Bypass Mode Enabled Channel Fault
RWPS Pump 9 Isolation Valve Bypass Mode Channel Fault
RWPS Pump 3 Suction Pressure Loss Channel Fault
RWPS Pump 9 PFCC Online Channel Fault
RWPS Pump 9 Suction Valve Remote Enabled Channel Fault
RWPS Pump 9 Suction Valve Local Enabled Channel Fault
RWPS Pump 9 Suction Valve High Torque Channel Fault
RWPS Pump 9 Suction Valve Open Status Channel Fault
RWPS Pump 9 Suction Valve Closed Status Channel Fault
RWPS Pump 9 Control Valve Maint. Mode Channel Fault
RWPS Pump 9 Control Valve Failure Channel Fault
RWPS Pump 9 Control Valve Open Status Channel Fault
RWPS Pump 9 Control Valve Closed Status Channel Fault
RWPS Pump 9 Discharge Valve Remote Enabled Channel Fault
RWPS Pump 9 Discharge Valve Local Enabled Channel Fault
RWPS Pump 9 Discharge Valve High Torque Channel Fault
RWPS Pump 9 Discharge Valve Open Status Channel Fault
RWPS Pump 9 Discharge Valve Closed Status Channel Fault
Spare
RWPS Stand-By Generator Run Status Channel Fault
RWPS Stand-By Generator Common Alarm Channel Fault
RWPS Stand-By Generator Low Fuel Channel Fault
RWPS Stand-By Generator Low Oil Pressure Channel Fault
RWPS Stand-By Generator Over Speed Channel Fault
RWPS Stand-By Generator Battery Sys Malfunction Channel Fault
Spare
RWPS 480V Switchgear Main "C3" Power Mode Channel Fault
RWPS 480V Switchgear "C3" Power Available Channel Fault
RWPS 480V Switchgear Main "D3" Power Mode Channel Fault
RWPS 480V Switchgear "D3" Power Available Channel Fault
RWPS 480V Switchgear Common Alarm Channel Fault
RWPS 480V Switchgear Transfer Failure Channel Fault
RWPS 480V Switchgear Tie No.1 Open Status Channel Fault
RWPS 480V Switchgear Tie No.2 Open Status Channel Fault
RWPS Pump 2 Suction Valve Open Command Channel Fault
RWPS Pump 2 Suction Valve Close Command Channel Fault
RWPS Pump 2 Discharge Valve Open Command Channel Fault
RWPS Pump 2 Discharge Valve Close Command Channel Fault
RWPS Pump 2 Scada Start Channel Fault
RWPS Pump 2 Scada Stop Channel Fault
RWPS Pump 2 Scada Lockout Channel Fault
RWPS Pump 2 Bypass Mode Command Channel Fault
RWPS East Intake Valve Open Command Channel Fault
RWPS East Intake Valve Close Command Channel Fault
RWPS East Suction Valve Open Command Channel Fault
RWPS East Suction Valve Close Command Channel Fault
Spare
Spare
Spare
RWPS AFD Pump 2 Speed Channel Fault
RWPS Motor 2 X-Direction Vibration Drive End Bearing
RWPS Pump 2 Discharge Pressure Channel Fault
RWPS Pump 2 X-Direction Vibration (Ce) Channel Fault
RWPS Pump 2 Cooling Water Flow Channel Fault
RWPS East Suction Pressure Channel Fault
RWPS Electrical Room Ambient Temperature Channel Fault
RWPS Reservoir Valve East Side Position Indication Channel Fault
RWPS Pump 1 Speed Setpoint Channel Fault
RWPS Reservoir Valve West Side Position Setpoint Channel Fault
RWPS Pump 9 Speed Setpoint Channel Fault
Spare
RWPS Northwest Sump Pump Auto Enabled Channel Fault
RWPS Northwest Sump Pump Run Status Channel Fault
RWPS Northwest Sump Pump Fault Channel Fault
RWPS Northwest Sump Pump Control Power Failure Channel Fault
RWPS Southwest By Pump 1 Sump Pump Auto Enabled Channel Fault
RWPS Southwest By Pump 1 Sump Pump Fault Channel Fault
RWPS Southwest By Pump 1 Sump Pump Control Power Failure Channel Fault
RWPS Southwest By Pump 4 Sump Pump Auto Enabled Channel Fault
RWPS Southwest By Pump 4 Sump Pump Run Status Channel Fault
RWPS Southwest By Pump 4 Sump Pump Fault Channel Fault
RWPS Southwest By Pump 4 Sump Pump Control Power Failure Channel Fault
RWPS West Alcove Sump Pump Auto Enabled Channel Fault
RWPS West Alcove Sump Pump Run Status Channel Fault
RWPS West Alcove Sump Pump Fault Channel Fault
RWPS East Elevator Sump Pump Control Power Failure Channel Fault
RWPS Northeast Sump Pump Run Status Channel Fault
RWPS Northeast Sump Pump Fault Channel Fault
RWPS Northeast Sump Pump Control Power Failure Channel Fault
RWPS Southeast Sump Pump Auto Enabled Channel Fault
RWPS Southeast Sump Pump Run Status Channel Fault
RWPS Southeast Sump Pump Fault Channel Fault
RWPS Southeast Sump Pump Control Power Failure Channel Fault
RWPS East Alcove Sump Pump Auto Enabled Channel Fault
RWPS East Alcove Sump Pump Run Status Channel Fault
RWPS East Alcove Sump Pump Fault Channel Fault
RWPS East Alcove Sump Pump Control Power Failure Channel Fault
RWPS West Elevator Sump Pump Auto Enabled Channel Fault
RWPS West Elevator Sump Pump Run Status Channel Fault
RWPS West Elevator Sump Pump Fault Channel Fault
RWPS West Elevator Sump Pump Control Power Failure Channel Fault
Spare
Spare
Spare
Spare
RWPS East Elevator Sump Pump Auto Enabled Channel Fault
RWPS East Elevator Sump Pump Run Status Channel Fault
RWPS East Elevator Sump Pump Fault Channel Fault
RWPS Northeast Sump Pump Auto Enabled Channel Fault
Spare
Spare
Spare
RWPS West Secondary Dewatering Pump A Auto Enabled Channel Fault
RWPS West Secondary Dewatering Pump A Run Status Channel Fault
RWPS West Secondary Dewatering Pump A Stop Status Channel Fault
RWPS West Secondary Dewatering Pump A Fault Channel Fault
RWPS West Secondary Dewatering SSRVS A Fault Channel Fault
RWPS West Secondary Dewatering Control Power Failure Channel Fault
RWPS West Secondary Dewatering High Level Alarm Channel Fault
RWPS West Secondary Dewatering Pump B Auto Enabled Channel Fault
RWPS West Secondary Dewatering Pump B Run Status Channel Fault
RWPS West Secondary Dewatering Pump B Stop Status Channel Fault
RWPS West Secondary Dewatering Pump B Fault Channel Fault
RWPS West Secondary Dewatering SSRVSB Fault Channel Fault
RWPS Intake Maintenance Dewatering Pump Run Channel Fault
RWPS Intake Maintenance Dewatering Pump Fault Channel Fault
Spare
Spare
RWPS East Secondary Dewatering Pump C Auto Enabled Channel Fault
RWPS East Secondary Dewatering Pump C Run Status Channel Fault
RWPS East Secondary Dewatering Pump C Stop Status Channel Fault
RWPS East Secondary Dewatering Pump C Fault Channel Fault
RWPS East Secondary Dewatering SSRVSC Fault Channel Fault
RWPS East Secondary Dewatering Control Power Failure Channel Fault
RWPS East Secondary Dewatering High Level Alarm Channel Fault
RWPS East Secondary Dewatering Pump D Auto Enabled Channel Fault
RWPS East Secondary Dewatering Pump D Run Status Channel Fault
RWPS East Secondary Dewatering Pump D Stop Status Channel Fault
RWPS East Secondary Dewatering Pump D Fault Channel Fault
RWPS East Secondary Dewatering SSRVSD Fault Channel Fault
RWPS Discharge Maintenance Dewatering Pump Run Channel Fault
RWPS Discharge Maintenance Dewatering Pump Fault Channel Fault
Spare
Spare
RWPS West Dam Collector Pump A Auto Enabled Channel Fault
RWPS West Dam Collector Pump A Run Status Channel Fault
RWPS West Dam Collector Pump A Fault Channel Fault
RWPS West Dam Collector Pump B Auto Enabled Channel Fault
RWPS West Dam Collector Pump B Run Status Channel Fault
RWPS West Dam Collector Pump B Fault Channel Fault
RWPS West Dam Collector Pump Control Power Failure Channel Fault
RWPS West Dam Collector Wet Well High Level Alarm Channel Fault
RWPS West Dam Collector Wet Well High-High Level Alarm Channel Fault
RWPS Substation Transformer 3 Low Oil Level Channel Fault
RWPS Substation Transformer 3 Pressure Relief Device Activation Channel Fault
RWPS Substation Transformer 5 Low Oil Level Channel Fault
RWPS Substation Transformer 5 Pressure Relief Device Activation Channel Fault
Spare
RWPS East Dam Collector Pump A Auto Enabled Channel Fault
RWPS East Dam Collector Pump A Run Status Channel Fault
RWPS East Dam Collector Pump A Fault Channel Fault
RWPS East Dam Collector Pump B Auto Enabled Channel Fault
RWPS East Dam Collector Pump B Run Status Channel Fault
RWPS East Dam Collector Pump B Fault Channel Fault
RWPS East Dam Collector Pump Control Power Failure Channel Fault
RWPS East Dam Collector Wet Well High Level Alarm Channel Fault
RWPS East Dam Collector Wet Well High-High Level Alarm Channel Fault
RWPS Substation Transformer 4 Low Oil Level Channel Fault
RWPS Substation Transformer 4 Pressure Relief Device Activation Channel Fault
RWPS Substation Transformer 6 Low Oil Level Channel Fault
RWPS Substation Transformer 6 Pressure Relief Device Activation Channel Fault
Spare
RWPS Pump 9 Suction Valve Open Command Channel Fault
RWPS Pump 9 Suction Valve Close Command Channel Fault
RWPS Pump 9 Discharge Valve Open Command Channel Fault
RWPS Pump 9 Discharge Valve Close Command Channel Fault
RWPS Pump 9 Scada Start Channel Fault
RWPS Pump 9 Scada Stop Channel Fault
RWPS Pump 9 Scada Lockout Channel Fault
RWPS Pump 9 Bypass Mode Command Channel Fault
RWPS To Reservoir East Suction Valve Open Command Channel Fault
RWPS To Reservoir East Suction Valve Close Command Channel Fault
RWPS To Reservoir East Sleeve Valve Open Command Channel Fault
RWPS To Reservoir East Sleeve Valve Close Command Channel Fault
RWPS To Reservoir East Discharge Valve Open Command Channel Fault
RWPS To Reservoir East Discharge Valve Close Command Channel Fault
Spare
RWPS AFD Pump 9 Speed Channel Fault
RWPS Motor 9 X-Direction Vibration Drive End Bearing Chanel Fault
RWPS Pump 9 Discharge Pressure Channel Fault
RWPS Pump 9 Cooling Water Flow Channel Fault
RWPS Discharge Pressure Channel Fault
RWPS Reservoir Release Flow Channel Fault
RWPS Pump 2 Speed Setpoint Channel Fault
RWPS Reservoir Valve East Side Position Setpoint Channel Fault
RWPS Pump 3 Speed Setpoint Channel Fault
RWPS AFD PUMP 4 SPEED Setpoint Channel Fault
RWPS West Pump Room Bypass Enabled Channel Fault
RWPS West Pump Room High Level Alarm Channel Fault
RWPS West Pump Hatch Open Channel Fault
RWPS West Alcove Hatch Open Channel Fault
RWPS West Elevator Common Alarm Channel Fault
RWPS West Stairwell Smoke Detected Channel Fault
Spare
RWPS Swb-0112-1 SPD Maintenance Alarm Channel Fault
RWPS Swg-0112-3A SPD Maintenance Alarm Channel Fault
RWPS Pp-0112-1 SPD Maintenance Alarm Channel Fault
RWPS Lp-0112-1 SPD Maintenance Alarm Channel Fault
RWPS Pp-0113-1 SPD Maintenance Alarm Channel Fault
RWPS Main "B1" Closed Status Channel Fault
RWPS Tie Breaker 1 Closed Status Channel Fault
Spare
RWPS East Pump Room Bypass Enabled Channel Fault
RWPS East Pump Room High Level Alarm Channel Fault
RWPS East Pump Hatch Open Channel Fault
RWPS East Alcove Hatch Open Channel Fault
RWPS East Elevator Common Alarm Channel Fault
RWPS East Stairwell Smoke Detected Channel Fault
RWPS Swb-0112-2 SPD Maintenance Alarm Channel Fault
RWPS Swg-0112-3B SPD Maintenance Alarm Channel Fault
RWPS Pp-0112-2 SPD Maintenance Alarm Channel Fault
RWPS Pp-0113-2 SPD Maintenance Alarm Channel Fault
RWPS Main "B2" Closed Status Channel Fault
RWPS Tie Breaker 2 Closed Status Channel Fault
Spare
RWPS Recloser 3 Open Status Channel Fault
RWPS Recloser 3 Close Status Channel Fault
RWPS Recloser 3 Trip Channel Fault
RWPS Plc Panel DC Power Ok Channel Fault
RWPS Plc Panel Door Open Channel Fault
RWPS Net Panel DC Power Ok Channel Fault
RWPS Net Panel Door Open Channel Fault
RWPS Scada UPS Panel Door Open Channel Fault
RWPS Scada UPS Panel UPS Alarm Channel Fault
RWPS Scada UPS Panel UPS Bypass Status Channel Fault
RWPS Security UPS Panel Door Open Channel Fault
RWPS Security UPS Panel UPS Alarm Channel Fault
RWPS Security UPS Panel UPS Bypass Status Channel Fault
Spare
Spare
Spare
RWPS Recloser 4 Open Status Channel Fault
RWPS Recloser 4 Close Status Channel Fault
RWPS Recloser 4 Trip Channel Fault
RWPS Electrical Building Intrusion Channel Fault
RWPS Elevator Pit Common High Level Alarm Channel Fault
RWPS To Reservoir 1000 Gal Pulse Channel Fault
Spare
Spare
Spare
Spare
Spare
Spare
RWPS West Pump Room Smoke Alarm Channel Fault
RWPS East Pump Room Smoke Alarm Channel Fault
Spare
Spare
Spare
RWPS Switchgear 0112-2 Common Alarm Channel Fault
RWPS Switchgear 0112-2 Main "A2" Closed Status Channel Fault
RWPS Switchgear 0112-2 "A2" Power Available Channel Fault
RWPS Switchgear 0112-2 Main "B2" Closed Status Channel Fault
RWPS Switchgear 0112-2 "B2" Power Available Channel Fault
RWPS Switchgear 0112-2 Main "G2" Closed Status Channel Fault
RWPS Switchgear 0112-2 "G2" Power Available Channel Fault
RWPS Switchgear 0112-2 Tie "No. 2" Open Status Channel Fault
RWPS Switchgear 0112-2 Transfer Failure Channel Fault
Active Harmonic Filter Common Alarm Channel Fault
Active Harmonic Filter Power On Channel Fault
RWPS Switchgear 0112-2 Main "A2" Closed Status Channel Fault
RWPS Switchgear 0112-2 Main "G2" Closed Status Channel Fault
Spare
Spare
Spare
RWPS Pump 7 Discharge Valve Open Command Channel Fault
RWPS Pump 7 Discharge Valve Close Command Channel Fault
RWPS Pump 7 Scada Start Channel Fault
RWPS Pump 7 Scada Stop Channel Fault
RWPS Pump 7 Scada Lockout Channel Fault
RWPS Pump 7 Scada Unplanned Stop Channel Fault
RWPS Pump 7 Suction Bypass Valve Open Command Channel Fault
RWPS Pump 7 Suction Bypass Valve Close Command Channel Fault
RWPS To Reservoir West Suction Valve Open Command Channel Fault
RWPS To Reservoir West Suction Valve Close Command Channel Fault
RWPS To Reservoir West Sleeve Valve Open Command Channel Fault
RWPS To Reservoir West Sleeve Valve Close Command Channel Fault
RWPS To Reservoir West Discharge Valve Open Command Channel Fault
RWPS To Reservoir West Discharge Valve Close Command Channel Fault
RWPS Pump 8 Discharge Pressure Channel Fault
RWPS Pump 8 Cooling Water Flow Channel Fault
RWPS PUMP 8 CONTROL VALVE POSITION INDICATION Channel Fault
RWPS Motor 8 X-Direction Vibration Drive End Bearing Channel Fault
RWPS Motor 8 Y-Direction Vibration Drive End Bearing Channel Fault
RWPS Motor 8 X-Direction Vibration Non-Drive End Bearing Channel Fault
Spare
RWPS AFD PUMP 5 SPEED Setpoint Channel Fault
Spare
Spare
Spare
Spare
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
Spare
Spare
Spare
RWPS Pump 5 Speed Setpoint
Spare
Spare
Spare
RWPS Pump 9 Auto Start
RWPS Pump 9 Auto Stop
RWPS Pump 2 Auto Start
RWPS Pump 2 Auto Stop
RWPS Pump 1 Auto Start
RWPS Pump 1 Auto Stop
RWPS West Intake Valve Close Auto Open
RWPS West Intake Valve Close Auto Close
RWPS West Suction Valve Auto Open
RWPS West Suction Valve Auto Close
RWPS East Intake Valve Auto Open
RWPS East Intake Valve Auto Close
RWPS East Suction Valve Auto Open
RWPS East Suction Valve Auto Close
RWPS To Reservoir West Suction Valve Auto Open
RWPS To Reservoir West Suction Valve Auto Close
RWPS To Reservoir West Discharge Valve Auto Open
RWPS To Reservoir West Discharge Valve Auto Close
RWPS To Reservoir East Suction Valve Auto Open
RWPS To Reservoir East Suction Valve Auto Close
RWPS To Reservoir East Discharge Valve Auto Open
RWPS To Reservoir East Discharge Valve Auto Close
Spare
Spare
RWPS West Intake Valve Remote Enabled
RWPS West Intake Valve Local Enabled
RWPS West Intake Valve Open Status
RWPS West Intake Valve Closed Status
RWPS West Suction Valve Remote Enabled
RWPS West Suction Valve Local Enabled
RWPS West Suction Valve Open Status
RWPS West Suction Valve Closed Status
RWPS East Intake Valve Remote Enabled
RWPS East Intake Valve Local Enabled
RWPS East Intake Valve Open Status
RWPS East Intake Valve Closed Status
RWPS East Suction Valve Remote Enabled
RWPS East Suction Valve Local Enabled
RWPS East Suction Valve Open Status
RWPS East Suction Valve Closed Status
RWPS To Reservoir West Suction Valve Local Enabled
RWPS To Reservoir West Suction Valve Remote Enabled
RWPS To Reservoir West Suction Valve Open Status
RWPS To Reservoir West Suction Valve Closed Status
RWPS To Reservoir West Sleeve Valve Local Enabled
RWPS To Reservoir West Sleeve Valve Remote Enabled
RWPS To Reservoir West Sleeve Valve Open Status
RWPS To Reservoir West Sleeve Valve Closed Status
RWPS To Reservoir West Discharge Valve Local Enabled
RWPS To Reservoir West Discharge Valve Remote Enabled
RWPS To Reservoir West Discharge Valve Open Status
RWPS To Reservoir West Discharge Valve Closed Status
RWPS To Reservoir East Suction Valve Local Enabled
RWPS To Reservoir East Suction Valve Remote Enabled
RWPS To Reservoir East Suction Valve Open Status
RWPS To Reservoir East Suction Valve Closed Status
RWPS To Reservoir East Sleeve Valve Local Enabled
RWPS To Reservoir East Sleeve Valve Remote Enabled
RWPS To Reservoir East Sleeve Valve Open Status
RWPS To Reservoir East Sleeve Valve Closed Status
RWPS To Reservoir East Discharge Valve Local Enabled
RWPS To Reservoir East Discharge Valve Remote Enabled
RWPS To Reservoir East Discharge Valve Open Status
RWPS To Reservoir East Discharge Valve Closed Status
RWPS Pump 1 Suction Valve Open Command
RWPS Pump 1 Suction Valve Close Command
RWPS Pump 1 Discharge Valve Open Command
RWPS Pump 1 Discharge Valve Close Command
RWPS Pump 1 Scada Start
RWPS Pump 1 Scada Stop
RWPS Pump 1 Scada Lockout
RWPS Pump 1 Bypass Mode Command
RWPS West Intake Valve Open Command
RWPS West Intake Valve Close Command
RWPS West Suction Valve Open Command
RWPS West Suction Valve Close Command
RWPS Pump 1 Scada Enabled
RWPS Pump 1 Ready
RWPS Pump 1 Run Status
RWPS Pump 1 Suction Valve Remote Enabled
RWPS Pump 1 Suction Valve Local Enabled
RWPS Pump 1 Suction Valve Open Status
RWPS Pump 1 Suction Valve Closed Status
RWPS Pump 1 Control Valve Maint. Mode
RWPS Pump 1 Control Valve Open Status
RWPS Pump 1 Control Valve Closed Status
RWPS Pump 1 Discharge Valve Remote Enabled
RWPS Pump 1 Discharge Valve Local Enabled
RWPS Pump 1 Discharge Valve Open Status
RWPS Pump 2 Ready
RWPS Pump 2 PFCC Online
RWPS Pump 2 Control Valve Maint. Mode
RWPS Pump 2 Control Valve Failure
RWPS Pump 9 Ready
RWPS Pump 9 Control Valve Maint. Mode
RWPS Pump 1 Available In Auto
RWPS Pump 2 Available In Auto
RWPS Pump 9 Available In Auto
RWPS Low Head AFD Number of Running Pumps
RWPS Low Head Pump Next Auto Start Permission ( Pump run < 2)
RWPS Terminal Storage Reservoir Level Ok to Start Pump Permissive
RWPS Pump 1 Priority
RWPS Pump 2 Priority
RWPS Pump 9 Priority
RWPS Low Head Pump Next Start Pump Priority
RWPS Pump 1 Start Flag
RWPS Pump 2 Start Flag
RWPS Pump 9 Start Flag
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
RWPS Low Head Pump Next Stop Pump Priority
RWPS Pump 1 Stop Flag
RWPS Pump 2 Stop Flag
RWPS Pump 9 Stop Flag
RWPS Meter Motorized Closed -Peer from Meter Vault PLC
RWPS Pump 9 HMI Lockout Flag
RWPS Pump 1 HMI Lockout Flag
RWPS Pump 2 HMI Lockout Flag
RWPS Reservoir Release Flow PID Parameters
11183
1.0
50.0
0.0
100.0
FALSE
FALSE
0.4
t#9s
0.1
1.0
RWPS To Reservoir Valves Required To Open
RWPS Reservoir Valve West Side Available
RWPS Reservoir Valve East Side Available
RWPS Reservoir Valve West Side Open Timer Expired. Time To Swamp Valve
RWPS Reservoir Valve East Side Open Timer Expired. Time To Swamp Valve
RWPS Pump 1 HMI Lockout Command
RWPS Pump 1 HMI Lockout Reset
RWPS Pump 2 Bypass Mode Command
RWPS Pump 2 Scada Lockout
RWPS Pump 2 HMI Lockout Command
RWPS Pump 2 HMI Lockout Reset
RWPS Pump 9 Bypass Mode Command
RWPS Pump 9 Scada Lockout
RWPS Pump 9 HMI Lockout Command
RWPS Pump 9 HMI Lockout Reset
RWPS Pump 9 Control Valve Failure
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
RWPS Motor 1 Y-Direction Vibration Drive End Bearing
RWPS Motor 1 Y-Direction Vibration Drive End Bearing
RWPS Motor 1 X-Direction Vibration Non-Drive End Bearing
RWPS Motor 1 Y-Direction Vibration Non-Drive End Bearing
RWPS Pump 1 X-Direction Vibration (Ce)
RWPS Pump 1 Y-Direction Vibration (Ce)
RWPS Pump 1 X-Direction Vibration (Obe)
RWPS Pump 1 Y-Direction Vibration (Obe)
RWPS Pump 1 Z-Direction Vibration (Obe)
RWPS Motor 1 X-Direction Vibration Non-Drive End Bearing Channel Fault
RWPS Motor 1 Y-Direction Vibration Non-Drive End Bearing Channel Fault
RWPS Pump 1 X-Direction Vibration (Ce) Channel Fault
RWPS Pump 1 Y-Direction Vibration (Ce) Channel Fault
RWPS Pump 1 X-Direction Vibration (Obe) Channel Fault
RWPS Pump 1 Y-Direction Vibration (Obe) Channel Fault
RWPS Pump 1 Z-Direction Vibration (Obe) Channel Fault
Rwps Motor 2 Y-Direction Vibration Drive End Bearing
Rwps Motor 2 X-Direction Vibration Non-Drive End Bearing
Rwps Motor 2 Y-Direction Vibration Non-Drive End Bearing
Rwps Pump 2 Y-Direction Vibration (Ce)
Rwps Pump 2 X-Direction Vibration (Obe)
Rwps Pump 2 Y-Direction Vibration (Obe)
Rwps Pump 2 Z-Direction Vibration (Obe)
Rwps Motor 2 Y-Direction Vibration Drive End Bearing Channel Fault
Rwps Motor 2 X-Direction Vibration Non-Drive End Bearing Channel Fault
Rwps Motor 2 Y-Direction Vibration Non-Drive End Bearing Channel Fault
Rwps Pump 2 Y-Direction Vibration (Ce) Channel Fault
Rwps Pump 2 X-Direction Vibration (Obe) Channel Fault
Rwps Pump 2 Y-Direction Vibration (Obe) Channel Fault
Rwps Pump 2 Z-Direction Vibration (Obe) Channel Fault
Spare
Spare
RWPS Motor 9 Y-Direction Vibration Drive End Bearing
RWPS Motor 9 X-Direction Vibration Non-Drive End Bearing
RWPS Motor 9 Y-Direction Vibration Non-Drive End Bearing
RWPS Pump 9 Y-Direction Vibration (Ce)
RWPS Pump 9 X-Direction Vibration (Obe)
RWPS Pump 9 Y-Direction Vibration (Obe)
RWPS Pump 9 Z-Direction Vibration (Obe)
RWPS Motor 9 Y-Direction Vibration Drive End Bearing Channel Fault
RWPS Motor 9 X-Direction Vibration Non-Drive End Bearing Channel Fault
RWPS Motor 9 Y-Direction Vibration Non-Drive End Bearing Channel Fault
RWPS Pump 9 Y-Direction Vibration (Ce) Channel Fault
RWPS Pump 9 X-Direction Vibration (Obe) Channel Fault
RWPS Pump 9 Y-Direction Vibration (Obe) Channel Fault
RWPS Pump 9 Z-Direction Vibration (Obe) Channel Fault
RWPS Pump 9 X-Direction Vibration (Ce) Channel Fault
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
RWPS East Hoistway Heat Detector
RWPS East Hoistway Heat Detector Channel Fault
RWPS East Pump Room Heat Alarm
RWPS East Pump Room Heat Alarm Channel Fault
RWPS Electrical Building Heat Alarm
RWPS Electrical Building Heat Alarm Channel Fault
RWPS Scada Room Heat Alarm
RWPS Scada Room Heat Alarm Channel Fault
RWPS Stand-By Generator High Water Teperature
RWPS Stand-By Generator High Water Teperature Channel Fault
RWPS Substation Transformer 3 Oil High Teperature
RWPS Substation Transformer 3 Oil High Teperature Channel Fault
RWPS Substation Transformer 3 Winding High Temperature
RWPS Substation Transformer 3 Winding High Teperature Channel Fault
RWPS Substation Transformer 4 Oil High Teperature
RWPS Substation Transformer 4 Oil High Teperature Channel Fault
RWPS Substation Transformer 4 Winding High Teperature
RWPS Substation Transformer 4 Winding High Teperature Channel Fault
RWPS Substation Transformer 5 Oil High Teperature
RWPS Substation Transformer 5 Oil High Teperature Channel Fault
RWPS Substation Transformer 5 Winding High Teperature
RWPS Substation Transformer 5 Winding High Teperature Channel Fault
RWPS Substation Transformer 6 Oil High Teperature
RWPS Substation Transformer 6 Oil High Teperature Channel Fault
RWPS Substation Transformer 6 Winding High Teperature
RWPS Substation Transformer 6 Winding High Teperature Channel Fault
RWPS West Hoistway Heat Detector
RWPS West Hoistway Heat Detector Channel Fault
RWPS West Pump Room Heat Alarm
RWPS West Pump Room Heat Alarm Channel Fault
RWPS Electrical Building Smoke Alarm
RWPS Electrical Building Smoke Alarm Channel Fault
RWPS (Ahu Sys Com) Condensate Overflow Alarm Channel Fault
RWPS (Ahu Sys Com) Dirty Filter Alarm Channel Fault
RWPS (Ahu Sys Com) Fan Failure Alarm Channel Fault
RWPS (Ahu Sys Com) Freeze Protection Alarm Channel Fault
RWPS (Ahu Sys Com) High Temperature Alarm Channel Fault
RWPS (Ahu Sys Com) Smoke Detector Alarm Channel Fault
RWPS (Ahu Sys Com) Space Temperature Alarm Channel Fault
RWPS (Chiller Sys Com) Chilled Water Pump Failure Channel Fault
RWPS (Chiller Sys Com) Chilled Water Supply High Temp Alarm Channel Fault
RWPS (Chiller Sys Com) Chiller Failure Alarm Channel Fault
RWPS (Chiller Sys Com) Cooling Water No Flow Channel Fault
RWPS (Chiller Sys Com) Proof Of Flow Channel Fault
RWPS (Doas Sys Com) Supply Air High Temp Channel Fault
RWPS (Doas Sys Com) Supply Air Low Temp Channel Fault
RWPS (Doas Sys Com) Supply Fan Failure Channel Fault
RWPS (Ef Com) Fan Failure Alarm Channel Fault
RWPS (Fcu Com) Fan Failure Alarm Channel Fault
RWPS (Fcu Com) Filter High Diff Pressure Alarm Channel Fault
RWPS (Sf Com) Fan Failure Alarm Channel Fault
RWPS Emergency Hvac Shutdown Channel Fault
RWPS Emergency Hvac Shutdown
RWPS (AUH SYS Com) Fan Failure Alarm
RWPS (AUH SYS Com) High Temperature Alarm
RWPS (AUH SYS Com) Space Temperature Alarm
RWPS (AUH SYS Com) Dirty Filter Alarm
RWPS (AUH SYS Com) Smoke Detector Alarm
RWPS (AUH SYS Com) Freeze Protection Alarm
RWPS (AUH SYS Com) Condensate Overflow Alarm
RWPS (Chiller SYS Com) Cooling Water No Flow
RWPS (Chiller SYS Com) Proof Of Flow
RWPS (Chiller SYS Com) Chilled Water Pump Failure
RWPS (Chiller SYS Com) Chiller Failure Alarm
RWPS (Chiller SYS Com) Chilled Water Supply High Temp Alarm
RWPS (Doas SYS Com) Supply Fan Failure
RWPS (Doas SYS Com) Supply Air High Temp
RWPS (Doas SYS Com) Supply Air Low Temp
RWPS (FCU Com) Filter High Diff Pressure Alarm
RWPS (FCU Com) Fan Failure Alarm
RWPS (EF Com) Fan Failure Alarm
RWPS (SF Com) Fan Failure Alarm
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
RWPS Low Head Pump Start Min Speed Sepoint Initiate
RWPS TSR Inlet Flow PID Parameters
11183
0.0
250.0
83.0
100.0
FALSE
FALSE
0.9
t#20s
1.0
0.0
RWPS Pump1 Auto Speed Request From PLC
RWPS Pump 2 Auto Speed Request From PLC
RWPS Pump 9 Auto Speed Request From PLC
RWPS Low Head AFD Number of Avail Pumps Not Running
RWPS Pump 1 to Min Speed Init - Stop Sequence
RWPS Pump 2 Start Sequence At Min Speed
RWPS Pump 9 Start Seq At Min Speed
RWPS Low Head Pumps All Auto Running Pump(s) Start Sequence At Min Speed
RWPS Low Head AFD Number of Running Pumps At The Time to Call For Another Pump To Run
RWPS Pump(s) to Min Speed Init - Stop Sequence
RWPS TSR Low Level - 2 Pumps Are Running. Run Pumps to 100%
RWPS TSR Inlet Flow PID In Process Manual
VFD LOWEST MIN SP
RWPS VFD HIGHEST MAX SP
RWPS TSR High Level Alarm Deadband
RWPS TSR High Level Shutdown Alarm
RWPS Pump 2 to Min Speed Init - Stop Sequence
RWPS Pump 9 to Min Speed Init -Stop Seq
RWPS All Low Head Pumps At Min Speed Init - Stop Sequence
RWPS Pump 1 Start Sequence At Min Speed
RWPS Low Head Pumps To Min Speed Setpoint Flag Reset
RWPS Low Head Pumps At Least 1 Pump Is Stop And Avail for Auto Start
RWPS Low Head Pumps At Least 1 Pump Is Running And Avail for Auto Stop
RWPS TSR High Level Alarm
RWPS High Level Float Switch High
RWPS TSR High Level Alarm Deadband
RWPS Pump 1 Initiates Swap Pump
RWPS Pump Swap Timer Holder
RWPS Pump 2 Initiates Swap Pump
RWPS Pump 9 Initiates Swap Pump
RWPS Low Head Number Of Pumps Currently Running In Auto
RWPS Low Head Number of Pump Running In Auto At Time To Swap
RWPS Low Head Pump Swap Sequence Checker - Only 1 Pump Is Running
RWPS Low Head Pump Swap Sequence Checker - More Than 1 Pumps Are Running
RWPS Low Head Pump At Least 1 Pump Is Running
RWPS Pump 9 Stop Initiate form Swap
RWPS Pump 9 Alternation Seq Completed
RWPS Pump 1 Stop Initiate from Swap
RWPS Pump 2 Stop Initiate from Swap
RWPS Pump 1 Alternation Seq Completed
RWPS Pump 2 Alternation Seq Completed
RWPS Low Head Pump Next Start From Swapping Sequence
RWPS Low Head Pump Set Running Pumps To Min Speed From Swap Sequence
RWPS Pump 1 Accuumulate Run Time
RWPS Pump 2 Accuumulate Run Time
RWPS Pump 9 Accuumulate Run Time
RWPS Low Head Pumps Max Running Hours
RWPS Low Head Pump Swap Timer Expired
RWPS Pump 1 Waiting To Start Another Pump Condition Met
RWPS Pump 2 Waiting To Start Another Pump Condition Met
RWPS Pump 9 Waiting To Start Another Pump Condition Met
RWPS Low Head Pump Start Waiting Done
RWPS Low Head Number Of Pump Control Valves Currently Open
RWPS Low Head Initial Number of PCVs Fully Open
RWPS Low Head Number Of Pump Control Valves Open At Swap Initiate
(OLD) Test different time setpoint
(OLD) Different Time Setpoint
RWPS Pump 9 Available In Local
RWPS Low Head AFD Number of Avail Pumps Regardless Of Running Status
RWPS Low Head Number Of Pumps In Local And Ready
RWPS Pump 1 Available In Local
RWPS Pump 2 Available In Local
RWPS Pumps SCADA Auto
RWPS Pump 1 AutomaticallyTo Man By Local And Ready Alarm
RWPS Pump 9 AutomaticallyTo Man By Local And Ready Alarm
RWPS Pump 2 AutomaticallyTo Man By Local And Ready Alarm
RWPS Pump 1 Local And Ready Alarm Flag
RWPS Pump 2 Local And Ready Alarm Flag
RWPS Pump 9 Local And Ready Alarm Flag
Turns on for 1 second after each pump's IRRdyFlag
RWPS VFD HIGHEST FB
RWPS Low Head Pump Swap Start Next Pump Permissive
RWPS Low Head Pump Swap Next Stop Permissive
RWPS Low Head Pump start or stop Sequence Active
RWPS Pump 1 Initiates Swap Pump - Call Other Pump Start Failure
RWPS Pump 2 Initiates Swap Pump - Call Other Pump Start Failure
RWPS Pump 9 Initiates Swap Pump - Call Other Pump Start Failure
RWPS Low Head Pump Next Pump Start Request Ton Flag
RWPS Low Head Pump Swap Fail Abort
RWPS Low Head Pump Swap Fail Pump Stop Command Reset
RWPS Swap Stop A Pump First - Pump 1 Initiate Sequence And Pump 1 FTS
RWPS Swap Stop A Pump First - Pump 2 Initiate Sequence And Pump 2 FTS
RWPS Swap Stop A Pump First - Pump 9 Initiate Sequence And Pump 9 FTS
RWPS Swap Run A Pump First - Pump 9 Initiate Sequence And Pump 9 FTS
RWPS Pump 1 Swap Unplanned Stop Cmd Flag
RWPS Pump 2 Swap Unplanned Stop Cmd Flag
RWPS Pump 9 Swap Unplanned Stop Cmd Flag
RWPS Swap Run A Pump First - Pump 2 Initiate Sequence And Pump 2 FTS
RWPS Swap Run A Pump First - Pump1 Initiate Sequence And Pump 1 FTS
RWPS Pump 1 Scada Unplanned Stop Channel Fault
RWPS Pump 2 Scada Unplanned Stop Channel Fault
RWPS Pump 9 Scada Unplanned Stop Channel Fault
Spare
Spare
Spare
RWPS Any Low Head Pump is Running and Valve Is Not Fully Open
RWPS Pump 1 Initiates Run First Swap And Fail Reset
RWPS Pump 2 Initiates Run First Swap And Fail Reset
RWPS Pump 9 Initiates Run First Swap And Fail Reset
RWPS Low Head Pump Swap Stop First And Fail Reset Counter Enable
RWPS Southwest By Pump 1 Sump Pump Run Status Channel Fault
RWPS TSR Inlet Flow PID Output Ramp Para for Loop in Process manual
0.0
0.0
(OLD) Elapsed Time from Older Section
RWPS Switchgear 0112-1 Common Alarm
RWPS Switchgear 0112-1 Main "A1" Closed Status
RWPS Switchgear 0112-1 "A1" Power Available
RWPS Switchgear 0112-1 Main "B1" Closed Status
RWPS Switchgear 0112-1 "B1" Power Available
RWPS Switchgear 0112-1 Main "G1" Closed Status
RWPS Switchgear 0112-1 "G1" Power Available
RWPS Switchgear 0112-1 Tie "No. 1" Open Status
RWPS Switchgear 0112-1 Tranfer Failure
Active Harmonic Filter Common Alarm
Active Harmonic Filter Power On
RWPS Switchgear 0112-1 Main "A1" Closed Status
RWPS Switchgear 0112-1 Main "G1" Closed Status
RWPS LP-0112-3 SPD Maintenance Alarm
RWPS LP-0112-4 SPD Maintenace Alarm
Spare
RWPS Switchgear 0112-1 Common Alarm Channel Fault
RWPS Switchgear 0112-1 Main "A1" Closed Status Channel Fault
RWPS Switchgear 0112-1 "A1" Power Available Channel Fault
RWPS Switchgear 0112-1 Main "B1" Closed Status Channel Fault
RWPS Switchgear 0112-1 "B1" Power Available Channel Fault
RWPS Switchgear 0112-1 Main "G1" Closed Status Channel Fault
RWPS Switchgear 0112-1 "G1" Power Available Channel Fault
RWPS Switchgear 0112-1 Tie "No. 1" Open Status Channel Fault
RWPS Switchgear 0112-1 Transfer Failure Channel Fault
Active Harmonic Filter Common Alarm Channel Fault
Active Harmonic Filter Power On Channel Fault
RWPS Switchgear 0112-1 Main "A1" Closed Status Channel Fault
RWPS Switchgear 0112-1 Main "G1" Closed Status Channel Fault
RWPS LP-0112-3 SPD Maintenance Alarm Channel Fault
RWPS LP-0112-4 SPD Maintenance Alarm Channel Fault
Spare
RWPS Substation Transformer 1 Low Oil Level
RWPS Substation Transformer 1 Oil High Temperature
RWPS Substation Transformer 1 Winding High Temperature
RWPS Substation Transformer 1 Pressure Relief Device Activation
RWPS Substation Transformer 2 Low Oil Level
RWPS Substation Transformer 2 Oil High Temperature
RWPS Substation Transformer 2 Winding High Temperature
RWPS Substation Transformer 2 Pressure Relief Device Activation
RWPS Recloser 1 Open Status
RWPS Recloser 1 Close Status
RWPS Recloser 1 Trip
RWPS Recloser 2 Open Status
RWPS Recloser 2 Close Status
RWPS Recloser 2 Trip
Spare
Spare
RWPS Substation Transformer 1 Low Oil Level Channel Fault
RWPS Substation Transformer 1 Oil High Temperature Channel Fault
RWPS Substation Transformer 1 Winding High Temperature Channel Fault
RWPS Substation Transformer 1 Pressure Relief Device Activation Channel Fault
RWPS Substation Transformer 2 Low Oil Level Channel Fault
RWPS Substation Transformer 2 Oil High Temperature Channel Fault
RWPS Substation Transformer 2 Winding High Temperature Channel Fault
RWPS Substation Transformer 2 Pressure Relief Device Activation Channel Fault
RWPS Recloser 1 Open Status Channel Fault
RWPS Recloser 1 Close Status Channel Fault
RWPS Recloser 1 Trip Channel Fault
RWPS Recloser 2 Open Status Channel Fault
RWPS Recloser 2 Close Status Channel Fault
RWPS Recloser 2 Trip Channel Fault
Spare
Spare
RWPS Low Head Pump Timer to hold sequence active to prevent Swap
Spare
Spare
RWPS Pump 3 Speed Setpoint
RWPS Pump 4 Speed Setpoint
RWPS West Alcove Sump Pump Control Power Failure
RWPS Flow To Reservoir Total Since Last Reset from PULSE
RWPS Flow To Reservoir Total Yesterday from PULSE
RWPS Flow To Reservoir Total Today from PULSE
Spare
Internal Tag used to block the SET of FCV_0113_2A as LEAD
More Than One Low Head Pumps are Running in Auto at Min Speeds - Command to Stop a Pump
Auto Position Setpoint Temp in % Open
Auto Position Setpoint Temp in % Open
Flow Control Inlet and Outlet VLV Auto Open Flag
Flow Control Inlet and Outlet VLV Auto Open Flag
RWPS Reservoir Lead-Lag Valve Order. (1 = Lead; 0 =Lag) Reset
RWPS TSR Low Level - 1 Pump is Running Start Another Pump
RWPS Meter Motorized open -Peer from Meter Vault PLC
Pump 1 Motor Seal Leak Raw Signal
RWPS Pump 2 Motor Seal Leak
RWPS Pump 9 Motor Seal Leak
Pump 1 Motor Seal Leak PLC Fault
RWPS Pump 2 Motor Seal Leak Channel Fault
RWPS Pump 9 Motor Seal Leak Channel Fault
RWPS Pump 9 Control Valve Position Indication
RWPS Pump 1 Control Valve Position Indication
RWPS Pump 2 Control Valve Position Indication
MV Switchgear PFCC 1 Inhibit Signal (PCO-48)
MV Switchgear PFCC 2 Inhibit Signal (PCO-48)
Meter Vault PLC Read Params
5
14081
0
8
Internal Tag for valve swap timer value
Swap delay in Time
Always False Instruction
Pump Coefficient of Friction
Any unplanned stop triggers this flag
RWPS West Alcove Sump Pump Control Power Failure Channel Fault
RWPS Pump 1 Control Valve Position Channel Fault
RWPS Pump 9 Control Valve Position Channel Fault
RWPS Pump 2 Control Valve Position Channel Fault
Spare
START TIME DELAY FOR PFCC INHIBIT SIGNAL TO PFCC 1
START TIME DELAY FOR PFCC INHIBIT SIGNAL TO PFCC 2
PFCC 1 Inhibit Timer
PFCC 2 Inhibit Timer
PFCC Inhibit Signal Active Warning
Bypass Mode Time Delay in Minutes
Bypass Mode Timer Time Delay Preset
Time Delay For Going To Bypass Mode
RWPS Pump 1 PCV Panel Not Ready/Fail Alarm
Pump 2 PCV Panel Not Ready/Fail Alarm
Pump 9 PCV Panel Not Ready/Fail Alarm
AFD 1 Month
AFD 2 Month
AFD 9 Month
Meter Vault Flow Signal Broken Loop Enabled
Meter Vault Flow Signal In Broken Loop
Meter Vault Flow is Bad
Time Delay For Going to Drive Mode
Time Delay For Going to Drive Mode
Drive Mode Timer Time Delay Preset
Both Tie Breakers are Closed
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
16#0001
RWPS Pump 3 Suction Valve Open Command
RWPS Pump 3 Suction Valve Close Command
RWPS Pump 3 Discharge Valve Open Command
RWPS Pump 3 Discharge Valve Close Command
RWPS Pump 3 Suction Bypass Valve Open Command
RWPS Pump 3 Suction Bypass Valve Close Command
RWPS Pump 3 Scada Start
RWPS Pump 3 Scada Stop
RWPS Pump 3 Scada Lockout
Spare - RWPS Pump 3 AFD Bypass Starter
Spare
RWPS Pump 4 Suction Valve Open Command
RWPS Pump 4 Suction Valve Close Command
RWPS Pump 4 Discharge Valve Open Command
RWPS Pump 4 Discharge Valve Close Command
RWPS Pump 3 Suction Valve Open Command Channel Fault
RWPS Pump 3 Suction Valve Close Command Channel Fault
RWPS Pump 3 Discharge Valve Open Command Channel Fault
RWPS Pump 3 Discharge Valve Close Command Channel Fault
RWPS Pump 3 Suction Bypass Valve Open Command Channel Fault
RWPS Pump 3 Suction Bypass Valve Close Command Channel Fault
RWPS Pump 3 Scada Start Channel Fault
RWPS Pump 3 Scada Stop Channel Fault
RWPS Pump 3 Scada Lockout Channel Fault
RWPS Pump 3 Scada Unplanned Stop Channel Fault
Spare
Spare
RWPS Pump 4 Suction Valve Open Command Channel Fault
RWPS Pump 4 Suction Valve Close Command Channel Fault
RWPS Pump 4 Discharge Valve Open Command Channel Fault
RWPS Pump 4 Discharge Valve Close Command Channel Fault
RWPS Pump 4 Suction Bypass Valve Open Command
RWPS Pump 4 Suction Bypass Valve Close Command
RWPS Pump 4 Scada Start
RWPS Pump 4 Scada Stop
RWPS Pump 4 Scada Lockout
Spare - RWPS Pump 4 AFD Bypass Starter
RWPS Pump 5 Suction Valve Open Command
RWPS Pump 5 Suction Valve Close Command
RWPS Pump 5 Discharge Valve Open Command
RWPS Pump 5 Discharge Valve Close Command
RWPS Pump 5 Suction Bypass Valve Open Command
RWPS Pump 5 Suction Bypass Valve Close Command
RWPS Pump 5 Scada Start
RWPS Pump 5 Scada Stop
RWPS Pump 5 Scada Lockout
RWPS Pump 4 Suction Bypass Valve Open Command Channel Fault
RWPS Pump 4 Suction Bypass Valve Close Command Channel Fault
RWPS Pump 4 Scada Start Channel Fault
RWPS Pump 4 Scada Stop Channel Fault
RWPS Pump 4 Scada Lockout Channel Fault
RWPS Pump 4 Scada Unplanned Stop Channel Fault
Spare
RWPS Pump 5 Suction Valve Open Command Channel Fault
RWPS Pump 5 Suction Valve Close Command Channel Fault
RWPS Pump 5 Discharge Valve Open Command Channel Fault
RWPS Pump 5 Discharge Valve Close Command Channel Fault
RWPS Pump 5 Suction Bypass Valve Open Command Channel Fault
RWPS Pump 5 Suction Bypass Valve Close Command Channel Fault
RWPS Pump 5 Scada Start Channel Fault
RWPS Pump 5 Scada Stop Channel Fault
RWPS Pump 5 Scada Lockout Channel Fault
Spare - RWPS Pump 5 AFD Bypass Starter
RWPS Pump 6 Suction Valve Open Command
RWPS Pump 6 Suction Valve Close Command
RWPS Pump 6 Discharge Valve Open Command
RWPS Pump 6 Discharge Valve Close Command
RWPS Pump 6 Suction Bypass Valve Open Command
RWPS Pump 6 Suction Bypass Valve Close Command
RWPS Pump 6 Scada Start
RWPS Pump 6 Scada Stop
RWPS Pump 6 Scada Lockout
Spare - RWPS Pump 6 AFD Bypass Starter
RWPS Pump 7 Suction Valve Open Command
RWPS Pump 7 Suction Valve Close Command
Spare
RWPS Pump 5 Scada Unplanned stop Channel Fault
Spare
RWPS Pump 6 Suction Valve Open Command Channel Fault
RWPS Pump 6 Suction Valve Close Command Channel Fault
RWPS Pump 6 Discharge Valve Open Command Channel Fault
RWPS Pump 6 Discharge Valve Close Command Channel Fault
RWPS Pump 6 Suction Bypass Valve Open Command Channel Fault
RWPS Pump 6 Suction Bypass Valve Close Command Channel Fault
RWPS Pump 6 Scada Start Channel Fault
RWPS Pump 6 Scada Stop Channel Fault
RWPS Pump 6 Scada Lockout Channel Fault
RWPS Pump 6 Scada Unplanned Stop Channel Fault
Spare
RWPS Pump 7 Suction Valve Open Command Channel Fault
RWPS Pump 7 Suction Valve Close Command Channel Fault
Spare
RWPS Pump 7 Discharge Valve Open Command
RWPS Pump 7 Discharge Valve Close Command
RWPS Pump 7 Suction Bypass Valve Open Command
RWPS Pump 7 Suction Bypass Valve Close Command
RWPS Pump 7 Scada Start
RWPS Pump 7 Scada Stop
RWPS Pump 7 Scada Lockout
Spare - RWPS Pump 3 AFD Bypass Starter
RWPS PUMP 3 DISCHARGE PRESSURE BYPASS MODE
RWPS PUMP 3 COOLING WATER FLOW FAILURE
RWPS PUMP 3 SCADA ENABLED
RWPS PUMP 3 READY
RWPS PUMP 3 AFD RUN STATUS
RWPS PUMP 3 E. STOP
RWPS PUMP 3 MPR ALARM
RWPS PUMP 3 HIGH RTD TEMP
RWPS PUMP 3 MPR TRIP
RWPS PUMP 3 AFD TRIP
RWPS PUMP 3 AFD E. STOP
RWPS PUMP 3 TEWAC MOTOR LEAK SENSOR
RWPS PUMP 3 ISOLATION VALVE BYPASS MODE
RWPS PUMP 3 SUCTION PRESSURE LOSS
RWPS PUMP 3 CONTROL VALVE THROTTLE BYPASS ENABLED
RWPS PUMP 3 SUCTION VALVE REMOTE ENABLED
RWPS PUMP 3 SUCTION VALVE LOCAL ENABLED
RWPS PUMP 3 SUCTION VALVE HIGH TORQUE
RWPS PUMP 3 SUCTION VALVE OPEN STATUS
RWPS PUMP 3 SUCTION VALVE CLOSED STATUS
RWPS PUMP 3 CONTROL VALVE MAINT. MODE
RWPS PUMP 3 CONTROL VALVE FAILURE
RWPS PUMP 3 CONTROL VALVE OPEN STATUS
RWPS PUMP 3 CONTROL VALVE CLOSED STATUS
RWPS PUMP 3 DISCHARGE VALVE REMOTE ENABLED
RWPS PUMP 3 DISCHARGE VALVE LOCAL ENABLED
RWPS PUMP 3 DISCHARGE VALVE HIGH TORQUE
RWPS PUMP 3 DISCHARGE VALVE OPEN STATUS
RWPS PUMP 3 DISCHARGE VALVE CLOSED STATUS
RWPS PUMP 3 SUCTION BYPASS VALVE REMOTE ENABLED
RWPS PUMP 3 SUCTION BYPASS VALVE LOCAL ENABLED
RWPS PUMP 3 SUCTION BYPASS VALVE HIGH TORQUE
RWPS PUMP 3 SUCTION BYPASS VALVE OPEN STATUS
RWPS PUMP 3 SUCTION BYPASS VALVE CLOSED STATUS
Spare - RWPS Pump 4 AFD Bypass Starter
RWPS PUMP 4 DISCHARGE PRESSURE BYPASS MODE
RWPS PUMP 4 COOLING WATER FLOW FAILURE
RWPS PUMP 4 SCADA ENABLED
RWPS PUMP 4 READY
RWPS PUMP 4 AFD RUN STATUS
RWPS PUMP 4 E. STOP
RWPS PUMP 4 MPR ALARM
RWPS PUMP 4 HIGH RTD TEMP
RWPS PUMP 4 MPR TRIP
RWPS PUMP 4 AFD TRIP
RWPS PUMP 4 AFD E. STOP
RWPS PUMP 4 TEWAC MOTOR LEAK SENSOR
RWPS PUMP 4 ISOLATION VALVE BYPASS MODE
RWPS PUMP 4 SUCTION PRESSURE LOSS
RWPS PUMP 4 CONTROL VALVE THROTTLE BYPASS ENABLED
RWPS PUMP 4 SUCTION VALVE REMOTE ENABLED
RWPS PUMP 4 SUCTION VALVE LOCAL ENABLED
RWPS PUMP 4 SUCTION VALVE HIGH TORQUE
RWPS PUMP 4 SUCTION VALVE OPEN STATUS
RWPS PUMP 4 SUCTION VALVE CLOSED STATUS
RWPS PUMP 4 CONTROL VALVE MAINT. MODE
RWPS PUMP 4 CONTROL VALVE FAILURE
RWPS PUMP 4 CONTROL VALVE OPEN STATUS
RWPS PUMP 4 CONTROL VALVE CLOSED STATUS
RWPS PUMP 4 DISCHARGE VALVE REMOTE ENABLED
RWPS PUMP 4 DISCHARGE VALVE LOCAL ENABLED
RWPS PUMP 4 DISCHARGE VALVE HIGH TORQUE
RWPS PUMP 4 DISCHARGE VALVE OPEN STATUS
RWPS PUMP 4 DISCHARGE VALVE CLOSED STATUS
RWPS PUMP 4 SUCTION BYPASS VALVE REMOTE ENABLED
RWPS PUMP 4 SUCTION BYPASS VALVE LOCAL ENABLED
RWPS PUMP 4 SUCTION BYPASS VALVE HIGH TORQUE
RWPS PUMP 4 SUCTION BYPASS VALVE OPEN STATUS
RWPS PUMP 4 SUCTION BYPASS VALVE CLOSED STATUS
RWPS PUMP 5 DISCHARGE PRESSURE BYPASS MODE
RWPS PUMP 5 COOLING WATER FLOW FAILURE
RWPS PUMP 5 SCADA ENABLED
RWPS PUMP 5 READY
RWPS PUMP 5 AFD RUN STATUS
RWPS PUMP 5 E. STOP
RWPS PUMP 5 MPR ALARM
RWPS AFD PUMP 3 SPEED
RWPS PUMP 3 DISCHARGE PRESSURE
RWPS PUMP 3 COOLING WATER FLOW
RWPS PUMP 3 CONTROL VALVE POSITION INDICATION
RWPS PUMP 3 X-DIRECTION VIBRATION (CE)
RWPS PUMP 3 Y-DIRECTION VIBRATION (CE)
RWPS PUMP 3 X-DIRECTION VIBRATION (OBE)
RWPS PUMP 3 Y-DIRECTION VIBRATION (OBE)
RWPS PUMP 3 Z-DIRECTION VIBRATION (OBE)
RWPS MOTOR 3 X-DIRECTION VIBRATION DRIVE END BEARING
RWPS MOTOR 3 Y-DIRECTION VIBRATION DRIVE END BEARING
RWPS MOTOR 3 X-DIRECTION VIBRATION NON-DRIVE END BEARING
RWPS MOTOR 3 Y-DIRECTION VIBRATION NON-DRIVE END BEARING
RWPS AFD PUMP 4 SPEED Indication
RWPS PUMP 4 DISCHARGE PRESSURE
RWPS PUMP 4 COOLING WATER FLOW
RWPS PUMP 4 CONTROL VALVE POSITION INDICATION
RWPS MOTOR 4 X-DIRECTION VIBRATION DRIVE END BEARING
RWPS MOTOR 4Y-DIRECTION VIBRATION DRIVE END BEARING
RWPS MOTOR 4X-DIRECTION VIBRATION NON-DRIVE END BEARING
RWPS MOTOR 4Y-DIRECTION VIBRATION NON-DRIVE END BEARING
RWPS PUMP 4 X-DIRECTION VIBRATION (CE)
RWPS PUMP 4 Y-DIRECTION VIBRATION (CE)
Spare
RWPS PUMP 5 HIGH RTD TEMP
RWPS PUMP 5 MPR TRIP
RWPS PUMP 5 AFD TRIP
RWPS PUMP 5 AFD E. STOP
RWPS PUMP 5 TEWAC MOTOR LEAK SENSOR
RWPS PUMP 5 ISOLATION VALVE BYPASS MODE
RWPS PUMP 5 SUCTION PRESSURE LOSS
RWPS PUMP 5 CONTROL VALVE THROTTLE BYPASS ENABLED
RWPS PUMP 5 SUCTION VALVE REMOTE ENABLED
RWPS PUMP 5 SUCTION VALVE LOCAL ENABLED
RWPS PUMP 5 SUCTION VALVE HIGH TORQUE
RWPS PUMP 5 SUCTION VALVE OPEN STATUS
RWPS PUMP 5 SUCTION VALVE CLOSED STATUS
RWPS PUMP 5 CONTROL VALVE MAINT. MODE
RWPS PUMP 5 CONTROL VALVE FAILURE
RWPS PUMP 5 CONTROL VALVE OPEN STATUS
RWPS PUMP 5 CONTROL VALVE CLOSED STATUS
RWPS PUMP 5 DISCHARGE VALVE REMOTE ENABLED
RWPS PUMP 5 DISCHARGE VALVE LOCAL ENABLED
RWPS PUMP 5 DISCHARGE VALVE HIGH TORQUE
RWPS PUMP 5 DISCHARGE VALVE OPEN STATUS
RWPS PUMP 5 DISCHARGE VALVE CLOSED STATUS
RWPS PUMP 5 SUCTION BYPASS VALVE REMOTE ENABLED
RWPS PUMP 5 SUCTION BYPASS VALVE LOCAL ENABLED
RWPS PUMP 5 SUCTION BYPASS VALVE HIGH TORQUE
RWPS PUMP 5 SUCTION BYPASS VALVE OPEN STATUS
RWPS PUMP 5 SUCTION BYPASS VALVE CLOSED STATUS
Spare - RWPS Pump 6 AFD Bypass Starter
RWPS PUMP 6 DISCHARGE PRESSURE BYPASS MODE
RWPS PUMP 6 COOLING WATER FLOW FAILURE
RWPS PUMP 6 SCADA ENABLED
RWPS PUMP 6 READY
RWPS PUMP 6 AFD RUN STATUS
RWPS PUMP 6 E. STOP
RWPS PUMP 6 MPR ALARM
RWPS PUMP 6 HIGH RTD TEMP
RWPS PUMP 6 MPR TRIP
RWPS PUMP 6 AFD TRIP
RWPS PUMP 6 AFD E. STOP
RWPS PUMP 6 TEWAC MOTOR LEAK SENSOR
RWPS PUMP 6 ISOLATION VALVE BYPASS MODE
RWPS PUMP 6 SUCTION PRESSURE LOSS
RWPS PUMP 6 CONTROL VALVE THROTTLE BYPASS ENABLED
RWPS PUMP 6 SUCTION VALVE REMOTE ENABLED
RWPS PUMP 6 SUCTION VALVE LOCAL ENABLED
RWPS PUMP 6 SUCTION VALVE HIGH TORQUE
RWPS PUMP 6 SUCTION VALVE OPEN STATUS
RWPS PUMP 6 SUCTION VALVE CLOSED STATUS
RWPS PUMP 6 CONTROL VALVE MAINT. MODE
RWPS PUMP 6 CONTROL VALVE FAILURE
RWPS PUMP 6 CONTROL VALVE OPEN STATUS
RWPS PUMP 6 CONTROL VALVE CLOSED STATUS
RWPS PUMP 6 DISCHARGE VALVE REMOTE ENABLED
RWPS PUMP 6 DISCHARGE VALVE LOCAL ENABLED
RWPS PUMP 6 DISCHARGE VALVE HIGH TORQUE
RWPS PUMP 6 DISCHARGE VALVE OPEN STATUS
RWPS PUMP 6 DISCHARGE VALVE CLOSED STATUS
RWPS PUMP 6 SUCTION BYPASS VALVE REMOTE ENABLED
RWPS PUMP 6 SUCTION BYPASS VALVE LOCAL ENABLED
RWPS PUMP 4 X-DIRECTION VIBRATION (OBE)
RWPS PUMP 4 Y-DIRECTION VIBRATION (OBE)
RWPS PUMP 4 Z-DIRECTION VIBRATION (OBE)
RWPS AFD PUMP 5 SPEED Indication
RWPS PUMP 5 DISCHARGE PRESSURE
RWPS PUMP 5 COOLING WATER FLOW
RWPS PUMP 5 CONTROL VALVE POSITION INDICATION
RWPS MOTOR 5 X-DIRECTION VIBRATION DRIVE END BEARING
RWPS MOTOR 5Y-DIRECTION VIBRATION DRIVE END BEARING
RWPS MOTOR 5X-DIRECTION VIBRATION NON-DRIVE END BEARING
RWPS MOTOR 5Y-DIRECTION VIBRATION NON-DRIVE END BEARING
RWPS PUMP 5 X-DIRECTION VIBRATION (CE)
RWPS PUMP 5 Y-DIRECTION VIBRATION (CE)
RWPS PUMP 5 X-DIRECTION VIBRATION (OBE)
RWPS PUMP 5 Y-DIRECTION VIBRATION (OBE)
RWPS PUMP 5 Z-DIRECTION VIBRATION (OBE)
RWPS AFD PUMP 6 SPEED
RWPS PUMP 6 DISCHARGE PRESSURE
RWPS PUMP 6 COOLING WATER FLOW
RWPS PUMP 6 CONTROL VALVE POSITION INDICATION
RWPS MOTOR 6 X-DIRECTION VIBRATION DRIVE END BEARING
RWPS MOTOR 6Y-DIRECTION VIBRATION DRIVE END BEARING
RWPS MOTOR 6X-DIRECTION VIBRATION NON-DRIVE END BEARING
RWPS MOTOR 6Y-DIRECTION VIBRATION NON-DRIVE END BEARING
RWPS PUMP 6 X-DIRECTION VIBRATION (CE)
RWPS PUMP 6 Y-DIRECTION VIBRATION (CE)
RWPS PUMP 6 X-DIRECTION VIBRATION (OBE)
RWPS PUMP 6 Y-DIRECTION VIBRATION (OBE)
RWPS PUMP 6 Z-DIRECTION VIBRATION (OBE)
RWPS AFD PUMP 7 SPEED
RWPS PUMP 7 DISCHARGE PRESSURE
RWPS PUMP 7 COOLING WATER FLOW
RWPS PUMP 6 SUCTION BYPASS VALVE HIGH TORQUE
RWPS PUMP 6 SUCTION BYPASS VALVE OPEN STATUS
RWPS PUMP 6 SUCTION BYPASS VALVE CLOSED STATUS
RWPS PUMP 7 DISCHARGE PRESSURE BYPASS MODE
RWPS PUMP 7 COOLING WATER FLOW FAILURE
RWPS PUMP 7 SCADA ENABLED
RWPS PUMP 7 READY
RWPS PUMP 7 AFD RUN STATUS
RWPS PUMP 7 E. STOP
RWPS PUMP 7 MPR ALARM
RWPS PUMP 7 HIGH RTD TEMP
RWPS PUMP 7 MPR TRIP
RWPS PUMP 7 AFD TRIP
RWPS PUMP 7 AFD E. STOP
RWPS PUMP 7 TEWAC MOTOR LEAK SENSOR
RWPS PUMP 7 ISOLATION VALVE BYPASS MODE
RWPS PUMP 7 SUCTION PRESSURE LOSS
RWPS PUMP 7 CONTROL VALVE THROTTLE BYPASS ENABLED
RWPS PUMP 7 SUCTION VALVE REMOTE ENABLED
RWPS PUMP 7 SUCTION VALVE LOCAL ENABLED
RWPS PUMP 7 SUCTION VALVE HIGH TORQUE
RWPS PUMP 7 SUCTION VALVE OPEN STATUS
RWPS PUMP 7 SUCTION VALVE CLOSED STATUS
RWPS PUMP 7 CONTROL VALVE MAINT. MODE
RWPS PUMP 7 CONTROL VALVE FAILURE
RWPS PUMP 7 CONTROL VALVE OPEN STATUS
RWPS PUMP 7 CONTROL VALVE CLOSED STATUS
RWPS PUMP 7 DISCHARGE VALVE REMOTE ENABLED
RWPS PUMP 7 DISCHARGE VALVE LOCAL ENABLED
RWPS PUMP 7 DISCHARGE VALVE HIGH TORQUE
RWPS PUMP 7 DISCHARGE VALVE OPEN STATUS
RWPS PUMP 7 DISCHARGE VALVE CLOSED STATUS
RWPS PUMP 7 SUCTION BYPASS VALVE REMOTE ENABLED
RWPS PUMP 7 SUCTION BYPASS VALVE LOCAL ENABLED
RWPS PUMP 7 SUCTION BYPASS VALVE HIGH TORQUE
RWPS PUMP 7 SUCTION BYPASS VALVE OPEN STATUS
RWPS PUMP 7 SUCTION BYPASS VALVE CLOSED STATUS
RWPS PUMP 8 DISCHARGE PRESSURE BYPASS MODE
RWPS PUMP 8 COOLING WATER FLOW FAILURE
RWPS PUMP 8 SCADA ENABLED
RWPS PUMP 8 READY
RWPS PUMP 8 AFD RUN STATUS
RWPS PUMP 8 E. STOP
RWPS PUMP 8 MPR ALARM
RWPS PUMP 8 HIGH RTD TEMP
RWPS PUMP 8 MPR TRIP
RWPS PUMP 8 AFD TRIP
RWPS PUMP 8 AFD E. STOP
RWPS PUMP 8 ISOLATION VALVE BYPASS MODE
RWPS PUMP 8 SUCTION PRESSURE LOSS
RWPS PUMP 8 CONTROL VALVE THROTTLE BYPASS ENABLED
RWPS PUMP 8 SUCTION VALVE REMOTE ENABLED
RWPS PUMP 8 SUCTION VALVE LOCAL ENABLED
RWPS PUMP 8 SUCTION VALVE HIGH TORQUE
RWPS PUMP 8 SUCTION VALVE OPEN STATUS
RWPS PUMP 8 SUCTION VALVE CLOSED STATUS
RWPS PUMP 8 CONTROL VALVE MAINT. MODE
RWPS PUMP 8 CONTROL VALVE FAILURE
RWPS PUMP 8 CONTROL VALVE OPEN STATUS
RWPS PUMP 8 CONTROL VALVE CLOSED STATUS
RWPS PUMP 8 TEWAC MOTOR LEAK SENSOR
RWPS PUMP 8 DISCHARGE VALVE REMOTE ENABLED
RWPS PUMP 8 DISCHARGE VALVE LOCAL ENABLED
RWPS PUMP 8 DISCHARGE VALVE HIGH TORQUE
RWPS PUMP 8 DISCHARGE VALVE OPEN STATUS
RWPS PUMP 8 DISCHARGE VALVE CLOSED STATUS
RWPS PUMP 8 SUCTION BYPASS VALVE REMOTE ENABLED
RWPS PUMP 8 SUCTION BYPASS VALVE LOCAL ENABLED
RWPS PUMP 8 SUCTION BYPASS VALVE HIGH TORQUE
RWPS PUMP 8 SUCTION BYPASS VALVE OPEN STATUS
RWPS PUMP 8 SUCTION BYPASS VALVE CLOSED STATUS
Spare
Spare
Spare
Spare
Spare
RWPS PUMP 8 SUCTION VALVE OPEN COMMAND
RWPS PUMP 8 SUCTION VALVE CLOSE COMMAND
RWPS PUMP 8 DISCHARGE VALVE OPEN COMMAND
RWPS PUMP 8 DISCHARGE VALVE CLOSE COMMAND
RWPS PUMP 8 SCADA START
RWPS PUMP 8 SCADA STOP
RWPS PUMP 8 SCADA LOCKOUT
RWPS PUMP 8 SUCTION BYPASS VALVE OPEN COMMAND
RWPS PUMP 8 SUCTION BYPASS VALVE CLOSE COMMAND
Spare - RWPS Pump 8 AFD Bypass Starter
Spare
Spare
Spare
Spare
Spare
RWPS PUMP 7 CONTROL VALVE POSITION INDICATION
RWPS MOTOR 7 X-DIRECTION VIBRATION DRIVE END BEARING
RWPS MOTOR 7 Y-DIRECTION VIBRATION DRIVE END BEARING
RWPS MOTOR 7 X-DIRECTION VIBRATION NON-DRIVE END BEARING
RWPS MOTOR 7 Y-DIRECTION VIBRATION NON-DRIVE END BEARING
RWPS PUMP 7 X-DIRECTION VIBRATION (CE)
RWPS PUMP 7 Y-DIRECTION VIBRATION (CE)
RWPS AFD PUMP 8 SPEED
RWPS PUMP 7 X-DIRECTION VIBRATION (OBE)
RWPS PUMP 7 Y-DIRECTION VIBRATION (OBE)
RWPS PUMP 7 Z-DIRECTION VIBRATION (OBE)
RWPS PUMP 8 X-DIRECTION VIBRATION (CE)
RWPS PUMP 8 Y-DIRECTION VIBRATION (CE)
RWPS PUMP 8 X-DIRECTION VIBRATION (OBE)
RWPS PUMP 8 Y-DIRECTION VIBRATION (OBE)
RWPS PUMP 8 Z-DIRECTION VIBRATION (OBE)
RWPS PUMP 6 SPEED SETPOINT
RWPS PUMP 7 SPEED SETPOINT
RWPS PUMP 8 SPEED SETPOINT
Spare
Spare
RWPS PUMP 3 DISCHARGE PRESSURE BYPASS MODE Channel Fault
RWPS PUMP 3 COOLING WATER FLOW FAILURE Channel Fault
RWPS PUMP 3 SCADA ENABLED Channel Fault
RWPS PUMP 3 READY Channel Fault
RWPS PUMP 3 AFD RUN STATUS Channel Fault
RWPS PUMP 3 E. STOP Channel Fault
RWPS PUMP 3 MPR ALARM Channel Fault
RWPS PUMP 3 HIGH RTD TEMP Channel Fault
RWPS PUMP 3 MPR TRIP Channel Fault
RWPS PUMP 3 AFD TRIP Channel Fault
RWPS PUMP 3 AFD E. STOP Channel Fault
RWPS PUMP 3 TEWAC MOTOR LEAK SENSOR Channel Fault
RWPS PUMP 3 ISOLATION VALVE BYPASS MODE Channel Fault
RWPS PUMP 3 SUCTION PRESSURE LOSS Channel Fault
RWPS PUMP 3 CONTROL VALVE THROTTLE BYPASS ENABLED Channel Fault
RWPS PUMP 3 SUCTION VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 3 SUCTION VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 3 SUCTION VALVE HIGH TORQUE Channel Fault
RWPS PUMP 3 SUCTION VALVE OPEN STATUS Channel Fault
RWPS PUMP 3 SUCTION VALVE CLOSED STATUS Channel Fault
RWPS PUMP 3 CONTROL VALVE MAINT. MODE Channel Fault
RWPS PUMP 3 CONTROL VALVE FAILURE Channel Fault
RWPS PUMP 3 CONTROL VALVE OPEN STATUS Channel Fault
RWPS PUMP 3 CONTROL VALVE CLOSED STATUS Channel Fault
RWPS PUMP 3 DISCHARGE VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 3 DISCHARGE VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 3 DISCHARGE VALVE HIGH TORQUE Channel Fault
RWPS PUMP 3 DISCHARGE VALVE OPEN STATUS Channel Fault
RWPS PUMP 3 DISCHARGE VALVE CLOSED STATUS Channel Fault
RWPS PUMP 3 SUCTION BYPASS VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 3 SUCTION BYPASS VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 3 SUCTION BYPASS VALVE HIGH TORQUE Channel Fault
RWPS PUMP 3 SUCTION BYPASS VALVE OPEN STATUS Channel Fault
RWPS PUMP 3 SUCTION BYPASS VALVE CLOSED STATUS Channel Fault
Spare
RWPS PUMP 4 DISCHARGE PRESSURE BYPASS MODE Channel Fault
RWPS PUMP 4 COOLING WATER FLOW FAILURE Channel Fault
RWPS PUMP 4 SCADA ENABLED Channel Fault
RWPS PUMP 4 READY Channel Fault
RWPS PUMP 4 AFD RUN STATUS Channel Fault
RWPS PUMP 4 E. STOP Channel Fault
RWPS PUMP 4 MPR ALARM Channel Fault
RWPS PUMP 4 HIGH RTD TEMP Channel Fault
RWPS PUMP 4 MPR TRIP Channel Fault
RWPS PUMP 4 AFD TRIP Channel Fault
RWPS PUMP 4 AFD E. STOP Channel Fault
RWPS PUMP 4 TEWAC MOTOR LEAK SENSOR Channel Fault
RWPS PUMP 4 ISOLATION VALVE BYPASS MODE Channel Fault
RWPS PUMP 4 SUCTION PRESSURE LOSS Channel Fault
RWPS PUMP 4 CONTROL VALVE THROTTLE BYPASS ENABLED Channel Fault
RWPS PUMP 4 SUCTION VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 4 SUCTION VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 4 SUCTION VALVE HIGH TORQUE Channel Fault
RWPS PUMP 4 SUCTION VALVE OPEN STATUS Channel Fault
RWPS PUMP 4 SUCTION VALVE CLOSED STATUS Channel Fault
RWPS PUMP 4 CONTROL VALVE MAINT. MODE Channel Fault
RWPS PUMP 4 CONTROL VALVE FAILURE Channel Fault
RWPS PUMP 4 CONTROL VALVE OPEN STATUS Channel Fault
RWPS PUMP 4 CONTROL VALVE CLOSED STATUS Channel Fault
RWPS PUMP 4 DISCHARGE VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 4 DISCHARGE VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 4 DISCHARGE VALVE HIGH TORQUE Channel Fault
RWPS PUMP 4 DISCHARGE VALVE OPEN STATUS Channel Fault
RWPS PUMP 4 DISCHARGE VALVE CLOSED STATUS Channel Fault
RWPS PUMP 4 SUCTION BYPASS VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 4 SUCTION BYPASS VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 4 SUCTION BYPASS VALVE HIGH TORQUE Channel Fault
RWPS PUMP 4 SUCTION BYPASS VALVE OPEN STATUS Channel Fault
RWPS PUMP 4 SUCTION BYPASS VALVE CLOSED STATUS Channel Fault
Spare
RWPS PUMP 5 DISCHARGE PRESSURE BYPASS MODE Channel Fault
RWPS PUMP 5 COOLING WATER FLOW FAILURE Channel Fault
RWPS PUMP 5 SCADA ENABLED Channel Fault
RWPS PUMP 5 READY Channel Fault
RWPS PUMP 5 AFD RUN STATUS Channel Fault
RWPS PUMP 5 E. STOP Channel Fault
RWPS PUMP 5 MPR ALARM Channel Fault
RWPS AFD PUMP 3 SPEED INdication Channel Fault
RWPS PUMP 3 DISCHARGE PRESSURE Channel Fault
RWPS PUMP 3 COOLING WATER FLOW Channel Fault
RWPS PUMP 3 CONTROL VALVE POSITION INDICATION Channel Fault
RWPS PUMP 3 X-DIRECTION VIBRATION (CE) Channel Fault
RWPS PUMP 3 Y-DIRECTION VIBRATION (CE) Channel Fault
RWPS PUMP 3 X-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 3 Y-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 3 Z-DIRECTION VIBRATION (OBE) Channel Fault
RWPS MOTOR 3 X-DIRECTION VIBRATION DRIVE END BEARING Channel Fault
RWPS MOTOR 3 Y-DIRECTION VIBRATION DRIVE END BEARING Channel Fault
RWPS MOTOR 3 X-DIRECTION VIBRATION NON-DRIVE END BEARING Channel Fault
RWPS MOTOR 3 Y-DIRECTION VIBRATION NON-DRIVE END BEARING Channel Fault
RWPS AFD PUMP 4 SPEED Indication Channel Fault
RWPS PUMP 4 DISCHARGE PRESSURE Channel Fault
RWPS PUMP 4 COOLING WATER FLOW Channel Fault
RWPS PUMP 4 CONTROL VALVE POSITION INDICATION Channel Fault
RWPS MOTOR 4 X-DIRECTION VIBRATION DRIVE END BEARING Channel Fault
RWPS MOTOR 4Y-DIRECTION VIBRATION DRIVE END BEARING Channel Fault
RWPS MOTOR 4X-DIRECTION VIBRATION NON-DRIVE END BEARING Channel Fault
RWPS MOTOR 4Y-DIRECTION VIBRATION NON-DRIVE END BEARING Channel Fault
RWPS PUMP 4 X-DIRECTION VIBRATION (CE) Channel Fault
RWPS PUMP 4 Y-DIRECTION VIBRATION (CE) Channel Fault
Spare
RWPS PUMP 5 HIGH RTD TEMP Channel Fault
RWPS PUMP 5 MPR TRIP Channel Fault
RWPS PUMP 5 AFD TRIP Channel Fault
RWPS PUMP 5 AFD E. STOP Channel Fault
RWPS PUMP 5 TEWAC MOTOR LEAK SENSOR Channel Fault
RWPS PUMP 5 ISOLATION VALVE BYPASS MODE Channel Fault
RWPS PUMP 5 SUCTION PRESSURE LOSS Channel Fault
RWPS PUMP 5 CONTROL VALVE THROTTLE BYPASS ENABLED Channel Fault
RWPS PUMP 5 SUCTION VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 5 SUCTION VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 5 SUCTION VALVE HIGH TORQUE Channel Fault
RWPS PUMP 5 SUCTION VALVE OPEN STATUS Channel Fault
RWPS PUMP 5 SUCTION VALVE CLOSED STATUS Channel Fault
RWPS PUMP 5 CONTROL VALVE MAINT. MODE Channel Fault
RWPS PUMP 5 CONTROL VALVE FAILURE Channel Fault
RWPS PUMP 5 CONTROL VALVE OPEN STATUS Channel Fault
RWPS PUMP 5 CONTROL VALVE CLOSED STATUS Channel Fault
RWPS PUMP 5 DISCHARGE VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 5 DISCHARGE VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 5 DISCHARGE VALVE HIGH TORQUE Channel Fault
RWPS PUMP 5 DISCHARGE VALVE OPEN STATUS Channel Fault
RWPS PUMP 5 DISCHARGE VALVE CLOSED STATUS Channel Fault
RWPS PUMP 5 SUCTION BYPASS VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 5 SUCTION BYPASS VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 5 SUCTION BYPASS VALVE HIGH TORQUE Channel Fault
RWPS PUMP 5 SUCTION BYPASS VALVE OPEN STATUS Channel Fault
RWPS PUMP 5 SUCTION BYPASS VALVE CLOSED STATUS Channel Fault
RWPS PUMP 6 DISCHARGE PRESSURE BYPASS MODE Channel Fault
RWPS PUMP 6 COOLING WATER FLOW FAILURE Channel Fault
RWPS PUMP 6 SCADA ENABLED Channel Fault
RWPS PUMP 6 READY Channel Fault
RWPS PUMP 6 AFD RUN STATUS Channel Fault
RWPS PUMP 6 E. STOP Channel Fault
RWPS PUMP 6 MPR ALARM Channel Fault
RWPS PUMP 6 HIGH RTD TEMP Channel Fault
RWPS PUMP 6 MPR TRIP Channel Fault
RWPS PUMP 6 AFD TRIP Channel Fault
RWPS PUMP 6 AFD E. STOP Channel Fault
RWPS PUMP 6 TEWAC MOTOR LEAK SENSOR Channel Fault
RWPS PUMP 6 ISOLATION VALVE BYPASS MODE Channel Fault
RWPS PUMP 6 SUCTION PRESSURE LOSS Channel Fault
RWPS PUMP 6 CONTROL VALVE THROTTLE BYPASS ENABLED Channel Fault
RWPS PUMP 6 SUCTION VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 6 SUCTION VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 6 SUCTION VALVE HIGH TORQUE Channel Fault
RWPS PUMP 6 SUCTION VALVE OPEN STATUS Channel Fault
RWPS PUMP 6 SUCTION VALVE CLOSED STATUS Channel Fault
RWPS PUMP 6 CONTROL VALVE MAINT. MODE Channel Fault
RWPS PUMP 6 CONTROL VALVE FAILURE Channel Fault
RWPS PUMP 6 CONTROL VALVE OPEN STATUS Channel Fault
RWPS PUMP 6 CONTROL VALVE CLOSED STATUS Channel Fault
RWPS PUMP 6 DISCHARGE VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 6 DISCHARGE VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 6 DISCHARGE VALVE HIGH TORQUE Channel Fault
RWPS PUMP 6 DISCHARGE VALVE OPEN STATUS Channel Fault
RWPS PUMP 6 DISCHARGE VALVE CLOSED STATUS Channel Fault
RWPS PUMP 6 SUCTION BYPASS VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 6 SUCTION BYPASS VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 4 X-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 4 Y-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 4 Z-DIRECTION VIBRATION (OBE) Channel Fault
RWPS AFD PUMP 5 SPEED Indication Channel Fault
RWPS PUMP 5 DISCHARGE PRESSURE Channel Fault
RWPS PUMP 5 COOLING WATER FLOW Channel Fault
RWPS PUMP 5 CONTROL VALVE POSITION INDICATION Channel Fault
RWPS MOTOR 5 X-DIRECTION VIBRATION DRIVE END BEARING Channel Fault
RWPS MOTOR 5Y-DIRECTION VIBRATION DRIVE END BEARING Channel Fault
RWPS MOTOR 5X-DIRECTION VIBRATION NON-DRIVE END BEARING Channel Fault
RWPS MOTOR 5Y-DIRECTION VIBRATION NON-DRIVE END BEARING Channel Fault
RWPS PUMP 5 X-DIRECTION VIBRATION (CE) Channel Fault
RWPS PUMP 5 Y-DIRECTION VIBRATION (CE) Channel Fault
RWPS PUMP 5 X-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 5 Y-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 5 Z-DIRECTION VIBRATION (OBE) Channel Fault
RWPS AFD PUMP 6 SPEED Indication Channel Fault
RWPS PUMP 6 DISCHARGE PRESSURE Channel Fault
RWPS PUMP 6 COOLING WATER FLOW Channel Fault
RWPS PUMP 6 CONTROL VALVE POSITION INDICATION Channel Fault
RWPS MOTOR 6 X-DIRECTION VIBRATION DRIVE END BEARING Channel Fault
RWPS MOTOR 6Y-DIRECTION VIBRATION DRIVE END BEARING Channel Fault
RWPS MOTOR 6X-DIRECTION VIBRATION NON-DRIVE END BEARING Channel Fault
RWPS MOTOR 6Y-DIRECTION VIBRATION NON-DRIVE END BEARING Channel Fault
RWPS PUMP 6 X-DIRECTION VIBRATION (CE) Channel Fault
RWPS PUMP 6 Y-DIRECTION VIBRATION (CE) Channel Fault
RWPS PUMP 6 X-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 6 Y-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 6 Z-DIRECTION VIBRATION (OBE) Channel Fault
RWPS AFD PUMP 7 SPEED Indication Channel Fault
RWPS PUMP 7 DISCHARGE PRESSURE Channel Fault
RWPS PUMP 7 COOLING WATER FLOW Channel Fault
RWPS PUMP 6 SUCTION BYPASS VALVE HIGH TORQUE Channel Fault
RWPS PUMP 6 SUCTION BYPASS VALVE OPEN STATUS Channel Fault
RWPS PUMP 6 SUCTION BYPASS VALVE CLOSED STATUS Channel Fault
RWPS PUMP 7 DISCHARGE PRESSURE BYPASS MODE Channel Fault
RWPS PUMP 7 COOLING WATER FLOW FAILURE Channel Fault
RWPS PUMP 7 SCADA ENABLED Channel Fault
RWPS PUMP 7 READY Channel Fault
RWPS PUMP 7 AFD RUN STATUS Channel Fault
RWPS PUMP 7 E. STOP Channel Fault
RWPS PUMP 7 MPR ALARM Channel Fault
RWPS PUMP 7 HIGH RTD TEMP Channel Fault
RWPS PUMP 7 MPR TRIP Channel Fault
RWPS PUMP 7 AFD TRIP Channel Fault
RWPS PUMP 7 AFD E. STOP Channel Fault
RWPS PUMP 7 TEWAC MOTOR LEAK SENSOR Channel Fault
RWPS PUMP 7 ISOLATION VALVE BYPASS MODE Channel Fault
RWPS PUMP 7 SUCTION PRESSURE LOSS Channel Fault
RWPS PUMP 7 CONTROL VALVE THROTTLE BYPASS ENABLED Channel Fault
RWPS PUMP 7 SUCTION VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 7 SUCTION VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 7 SUCTION VALVE HIGH TORQUE Channel Fault
RWPS PUMP 7 SUCTION VALVE OPEN STATUS Channel Fault
RWPS PUMP 7 SUCTION VALVE CLOSED STATUS Channel Fault
RWPS PUMP 7 CONTROL VALVE MAINT. MODE Channel Fault
RWPS PUMP 7 CONTROL VALVE FAILURE Channel Fault
RWPS PUMP 7 CONTROL VALVE OPEN STATUS Channel Fault
RWPS PUMP 7 CONTROL VALVE CLOSED STATUS Channel Fault
RWPS PUMP 7 DISCHARGE VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 7 DISCHARGE VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 7 DISCHARGE VALVE HIGH TORQUE Channel Fault
RWPS PUMP 7 DISCHARGE VALVE OPEN STATUS Channel Fault
RWPS PUMP 7 DISCHARGE VALVE CLOSED STATUS Channel Fault
RWPS PUMP 7 SUCTION BYPASS VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 7 SUCTION BYPASS VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 7 SUCTION BYPASS VALVE HIGH TORQUE Channel Fault
RWPS PUMP 7 SUCTION BYPASS VALVE OPEN STATUS Channel Fault
RWPS PUMP 7 SUCTION BYPASS VALVE CLOSED STATUS Channel Fault
RWPS PUMP 8 DISCHARGE PRESSURE BYPASS MODE Channel Fault
RWPS PUMP 8 COOLING WATER FLOW FAILURE Channel Fault
RWPS PUMP 8 SCADA ENABLED Channel Fault
RWPS PUMP 8 READY Channel Fault
RWPS PUMP 8 AFD RUN STATUS Channel Fault
RWPS PUMP 8 E. STOP Channel Fault
RWPS PUMP 8 MPR ALARM Channel Fault
RWPS PUMP 8 HIGH RTD TEMP Channel Fault
RWPS PUMP 8 MPR TRIP Channel Fault
RWPS PUMP 8 AFD TRIP Channel Fault
RWPS PUMP 8 AFD E. STOP Channel Fault
RWPS PUMP 8 ISOLATION VALVE BYPASS MODE Channel Fault
RWPS PUMP 8 SUCTION PRESSURE LOSS Channel Fault
RWPS PUMP 8 CONTROL VALVE THROTTLE BYPASS ENABLED Channel Fault
RWPS PUMP 8 SUCTION VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 8 SUCTION VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 8 SUCTION VALVE HIGH TORQUE Channel Fault
RWPS PUMP 8 SUCTION VALVE OPEN STATUS Channel Fault
RWPS PUMP 8 SUCTION VALVE CLOSED STATUS Channel Fault
RWPS PUMP 8 CONTROL VALVE MAINT. MODE Channel Fault
RWPS PUMP 8 CONTROL VALVE FAILURE Channel Fault
RWPS PUMP 8 CONTROL VALVE OPEN STATUS Channel Fault
RWPS PUMP 8 CONTROL VALVE CLOSED STATUS Channel Fault
RWPS PUMP 8 TEWAC MOTOR LEAK SENSOR Channel Fault
RWPS PUMP 8 DISCHARGE VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 8 DISCHARGE VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 8 DISCHARGE VALVE HIGH TORQUE Channel Fault
RWPS PUMP 8 DISCHARGE VALVE OPEN STATUS Channel Fault
RWPS PUMP 8 DISCHARGE VALVE CLOSED STATUS Channel Fault
RWPS PUMP 8 SUCTION BYPASS VALVE REMOTE ENABLED Channel Fault
RWPS PUMP 8 SUCTION BYPASS VALVE LOCAL ENABLED Channel Fault
RWPS PUMP 8 SUCTION BYPASS VALVE HIGH TORQUE Channel Fault
RWPS PUMP 8 SUCTION BYPASS VALVE OPEN STATUS Channel Fault
RWPS PUMP 8 SUCTION BYPASS VALVE CLOSED STATUS Channel Fault
Spare
Spare
Spare
Spare
Spare
RWPS PUMP 8 SUCTION VALVE OPEN COMMAND Channel Fault
RWPS PUMP 8 SUCTION VALVE CLOSE COMMAND Channel Fault
RWPS PUMP 8 DISCHARGE VALVE OPEN COMMAND Channel Fault
RWPS PUMP 8 DISCHARGE VALVE CLOSE COMMAND Channel Fault
RWPS PUMP 8 SCADA START Channel Fault
RWPS PUMP 8 SCADA STOP Channel Fault
RWPS PUMP 8 SCADA LOCKOUT Channel Fault
RWPS PUMP 8 UNPLANNED STOP COMMAND Channel Fault
RWPS PUMP 8 SUCTION BYPASS VALVE OPEN COMMAND Channel Fault
RWPS PUMP 8 SUCTION BYPASS VALVE CLOSE COMMAND Channel Fault
Spare
Spare
Spare
Spare
Spare
Spare
RWPS PUMP 7 CONTROL VALVE POSITION INDICATION Channel Fault
RWPS MOTOR 7 X-DIRECTION VIBRATION DRIVE END BEARING Channel Fault
RWPS MOTOR 7 Y-DIRECTION VIBRATION DRIVE END BEARING Channel Fault
RWPS MOTOR 7 X-DIRECTION VIBRATION NON-DRIVE END BEARING Channel Fault
RWPS MOTOR 7 Y-DIRECTION VIBRATION NON-DRIVE END BEARING Channel Fault
RWPS PUMP 7 X-DIRECTION VIBRATION (CE) Channel Fault
RWPS PUMP 7 Y-DIRECTION VIBRATION (CE) Channel Fault
RWPS AFD PUMP 8 SPEED Channel Fault
RWPS PUMP 7 X-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 7 Y-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 7 Z-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 8 X-DIRECTION VIBRATION (CE) Channel Fault
RWPS PUMP 8 Y-DIRECTION VIBRATION (CE) Channel Fault
RWPS PUMP 8 X-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 8 Y-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 8 Z-DIRECTION VIBRATION (OBE) Channel Fault
RWPS PUMP 6 SPEED SETPOINT Channel Fault
RWPS PUMP 7 SPEED SETPOINT Channel Fault
RWPS PUMP 8 SPEED SETPOINT Channel Fault
Spare
RWPS Motor 8 Y-Direction Vibration Non-Drive End Bearing Channel Fault
RWPS PUMP 3 CONTROL VALVE PANEL TRIP
RWPS PUMP 3 CONTROL VALVE PANEL WARNING
RWPS PUMP 3 CONTROL VALVE PANEL TRIP Channel Fault
RWPS PUMP 3 CONTROL VALVE PANEL WARNING Channel Fault
RWPS PUMP 4 CONTROL VALVE PANEL TRIP
RWPS PUMP 4 CONTROL VALVE PANEL WARNING
RWPS PUMP 4 CONTROL VALVE PANEL TRIP Channel Fault
RWPS PUMP 4 CONTROL VALVE PANEL WARNING Channel Fault
Spare - RWPS Pump 5 AFD Bypass Starter
Spare
Spare
RWPS PUMP 5 CONTROL VALVE PANEL TRIP
RWPS PUMP 5 CONTROL VALVE PANEL WARNING
RWPS PUMP 5 CONTROL VALVE PANEL TRIP Channel Fault
RWPS PUMP 5 CONTROL VALVE PANEL WARNING Channel Fault
Spare
RWPS PUMP 6 CONTROL VALVE PANEL TRIP
RWPS PUMP 6 CONTROL VALVE PANEL WARNING
RWPS PUMP 6 CONTROL VALVE PANEL TRIP Channel Fault
RWPS PUMP 6 CONTROL VALVE PANEL WARNING Channel Fault
Spare
Spare - RWPS Pump 7 AFD Bypass Starter
RWPS PUMP 7 CONTROL VALVE PANEL TRIP
RWPS PUMP 7 CONTROL VALVE PANEL WARNING
RWPS PUMP 7 CONTROL VALVE PANEL TRIP Channel Fault
RWPS PUMP 7 CONTROL VALVE PANEL WARNING Channel Fault
Spare - RWPS Pump 8 AFD Bypass Starter
Spare
Spare
Spare
RWPS PUMP 8 CONTROL VALVE PANEL TRIP
RWPS PUMP 8 CONTROL VALVE PANEL WARNING
RWPS PUMP 8 CONTROL VALVE PANEL TRIP Channel Fault
RWPS PUMP 8 CONTROL VALVE PANEL WARNING Channel Fault
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Any pump is running
Pump Room High Level Alarm Active and all pumps are stopped
RWPS West Intake Valve Any Channel Fault
RWPS West Suction Valve Any Channel Fault
RWPS East Intake Valve Any Channel Fault
RWPS East Suction Valve Any Channel Fault
RWPS To Reservoir West Suction Valve Any Channel Fault
RWPS To Reservoir West Discharge Valve Any Channel Fault
RWPS To Reservoir East Suction Valve Any Channel Fault
RWPS To Reservoir East Discharge Valve Any Channel Fault
RWPS Pump 1 Suction Valve Any Channel Fault
RWPS Pump 1 Discharge Valve Any Channel Fault
RWPS Pump 2 Suction Valve Any Channel Fault
RWPS Pump 2 Discharge Valve Any Channel Fault
RWPS Pump 9 Suction Valve Any Channel Fault
RWPS Pump 9 Discharge Valve Any Channel Fault
RWPS Pump 3 Suction Valve Any Channel Fault
RWPS Pump 3 Suction Bypass Valve Any Channel Fault
RWPS Pump 3 Discharge Valve Any Channel Fault
RWPS Pump 4 Suction Valve Any Channel Fault
RWPS Pump 4 Suction Bypass Valve Any Channel Fault
RWPS Pump 4 Discharge Valve Any Channel Fault
RWPS Pump 5 Suction Valve Any Channel Fault
RWPS Pump 5 Suction Bypass Valve Any Channel Fault
RWPS Pump 5 Discharge Valve Any Channel Fault
RWPS Pump 6 Suction Valve Any Channel Fault
RWPS Pump 6 Suction Bypass Valve Any Channel Fault
RWPS Pump 6 Discharge Valve Any Channel Fault
RWPS Pump 7 Suction Valve Any Channel Fault
RWPS Pump 8 Suction Valve Any Channel Fault
RWPS Pump 7 Suction Bypass Valve Any Channel Fault
RWPS Pump 7 Discharge Valve Any Channel Fault
RWPS Pump 8 Suction Bypass Valve Any Channel Fault
RWPS Pump 8 Discharge Valve Any Channel Fault
(NOT ACTIVE) RWPS Pump 3 In Bypass Mode (%MW110.02)
RWPS Pump 3 Auto Speed Request from PLC
RWPS Pump 3 Auto Stop
(NOT USED) RWPS Pump 3 Control Valve Not Ready Alarm
RWPS Pump 3 Auto Start
RWPS PUMP 4 Auto Speed Request from PLC
RWPS Pump 4 Auto Stop
(NOT USED) RWPS Pump 4 Control Valve Not Ready
RWPS Pump 4 Auto Start
(NOT ACTIVE) RWPS Pump 4 In Bypass Mode (%MW110.03)
(NOT ACTIVE) RWPS Pump 5 In Bypass Mode (%MW110.04)
RWPS PUMP 5 Auto Speed Request from PLC
RWPS Pump 5 Auto Stop
(NOT USED) RWPS Pump 5 Control Valve Not Ready
RWPS Pump 5 Auto Start
RWPS Pump 6 Auto Speed Request from PLC
RWPS Pump 6 Auto Stop
(NOT USED) RWPS Pump 6 Control Valve Not Ready
RWPS Pump 6 Auto Start
(NOT ACTIVE) RWPS Pump 6 In Bypass Mode (%MW110.05)
(NOT ACTIVE) RWPS Pump 7 In Bypass Mode (%MW110.06)
RWPS Pump 7 Auto Speed Request from PLC
RWPS Pump 7 Auto Stop
(NOT USED) RWPS Pump 7 Control Valve Not Ready
RWPS Pump 7 Auto Start
(NOT ACTIVE) RWPS Pump 8 In Bypass Mode (%MW110.07)
RWPS Pump 8 Auto Speed Request from PLC
RWPS Pump 8 Auto Stop
(NOT USED) RWPS Pump 8 Control Valve Not Ready
RWPS Pump 8 Auto Start
RWPS Pump 3 HMI Lockout Command
RWPS Pump 3 HMI Lockout Reset
RWPS Pump 4 HMI Lockout Command
RWPS Pump 4 HMI Lockout Reset
RWPS Pump 5 HMI Lockout Command
RWPS Pump 5 HMI Lockout Reset
RWPS Pump 6 HMI Lockout Command
RWPS Pump 6 HMI Lockout Reset
RWPS Pump 7 HMI Lockout Command
RWPS Pump 7 HMI Lockout Reset
RWPS Pump 8 HMI Lockout Command
RWPS Pump 8 HMI Lockout Reset
North TSR Level
South TSR Level
North TSR High Level Float
North TSR Level Bypass Selection (1 = Bypass / 0 = Normal)
South TSR High Level Float
South TSR Level Bypass Selection (1 = Bypass / 0 = Normal)
RWPS Select which TSR to use for the Level Indication and Level Switch High (1 = North / 0 = South)
RWPS TSR Selected Analog Level
RWPS Pump 1 is Auto Ready (Not Running, Ready, No Stop Flag, and Auto Available)
RWPS Pump 2 is Auto Ready (Not Running, Ready, No Stop Flag, and Auto Available)
RWPS Pump 9 is Auto Ready (Not Running, Ready, No Stop Flag, and Auto Available)
RWPS Pump 1 is Auto Running with PCV Fully Open
RWPS Pump 2 is Auto Running with PCV Fully Open
RWPS Pump 9 is Auto Running with PCV Fully Open
RWPS Pump 1 Runtime Totalizer Mode (Hold runtime and reset commands)
RWPS Pump Parameter for Runtime Totalizers used for swap sequences
3600.0
0.0
FALSE
RWPS Pump 1 Runtime Totalizer Initialize Value
RWPS Pump 1 Runtime Totalizer Initialize Command (OUTC to INIT_VALUE)
RWPS Pump 1 Runtime Totalizer Output value from Zero to Threshhold then restarts
RWPS Pump 1 Runtime Totalizer (outc is the runtime in seconds)
RWPS Pump 1 Runtime Totalizer Status Information
RWPS Pump 2 Runtime Totalizer Mode (Hold runtime and reset commands)
RWPS Pump 2 Runtime Totalizer Initialize Command (OUTC to INIT_VALUE)
RWPS Pump 2 Runtime Totalizer Initialize Value
RWPS Pump 2 Runtime Totalizer (outc is the runtime in seconds)
RWPS Pump 2 Runtime Totalizer Output value from Zero to Threshhold then restarts
RWPS Pump 2 Runtime Totalizer Status Information
RWPS Pump 9 Runtime Totalizer Mode (Hold runtime and reset commands)
RWPS Pump 9 Runtime Totalizer Initialize Command (OUTC to INIT_VALUE)
RWPS Pump 9 Runtime Totalizer Initialize Value
RWPS Pump 9 Runtime Totalizer (outc is the runtime in seconds)
RWPS Pump 9 Runtime Totalizer Output value from Zero to Threshhold then restarts
RWPS Pump 9 Runtime Totalizer Status Information
RWPS Pump 1 Priority (Used to determine Next pump to Start) passed to this tag when Not Running, Ready, in Auto and Available with Permissive
RWPS Pump 2 Priority (Used to determine Next pump to Start) passed to this tag when Not Running, Ready, in Auto and Available with Permissive
RWPS Pump 9 Priority (Used to determine Next pump to Start) passed to this tag when Not Running, Ready, in Auto and Available with Permissive
Internal Tag for Low Head Pumps used for Next Start Requests
RWPS Pump 1 Priority (Used to determine Next pump to Stop) passed to this tag when Running in Auto and Available with Permissive
RWPS Pump 2 Priority (Used to determine Next pump to Stop) passed to this tag when Running in Auto and Available with Permissive
RWPS Pump 9 Priority (Used to determine Next pump to Stop) passed to this tag when Running in Auto and Available with Permissive
RWPS TSR Selected Analog Level Switch is Normal
RWPS TSR midpoint between the high and low level bands
RWPS TSR Analog Input High High Unplanned Stop
RWPS TSR High Level Switch Unplanned Stop
RWPS High Head AFD Number of Pumps Running or commanded to Run
RWPS Pump 3 Available In Auto
RWPS Pump 4 Available In Auto
RWPS Pump 5 Available In Auto
RWPS Pump 6 Available In Auto
RWPS Pump 7 Available In Auto
RWPS Pump 8 Available In Auto
RWPS High Head AFD Number of Avail Pumps and Running
(NOT ACTIVE) RWPS Pump 3 Bypass Mode Command (%MW102.02)
(NOT ACTIVE) RWPS Pump 4 Bypass Mode Command (%MW102.03)
(NOT ACTIVE) RWPS Pump 5 Bypass Mode Command (%MW102.04)
(NOT ACTIVE) RWPS Pump 6 Bypass Mode Command (%MW102.05)
(NOT ACTIVE) RWPS Pump 7 Bypass Mode Command (%MW102.06)
(NOT ACTIVE) RWPS Pump 8 Bypass Mode Command (%MW102.07)
RWPS Pump 3 Available In Local
RWPS Pump 4 Available In Local
RWPS Pump 5 Available In Local
RWPS Pump 6 Available In Local
RWPS Pump 7 Available In Local
RWPS Pump 8 Available In Local
RWPS High Head Number Of Pumps In Local And Ready
RWPS High Head AFD Number of Avail Pumps Regardless Of Running Status
RWPS Pump 3 is Auto Ready (Not Running, Ready, No Stop Flag, and Auto Available)
RWPS Pump 6 is Auto Ready (Not Running, Ready, No Stop Flag, and Auto Available)
RWPS Pump 4 is Auto Ready (Not Running, Ready, No Stop Flag, and Auto Available)
RWPS Pump 7 is Auto Ready (Not Running, Ready, No Stop Flag, and Auto Available)
RWPS Pump 5 is Auto Ready (Not Running, Ready, No Stop Flag, and Auto Available)
RWPS Pump 8 is Auto Ready (Not Running, Ready, No Stop Flag, and Auto Available)
RWPS High Head AFD Number of Avail Pumps Ready
RWPS Pump 3 is Auto Running with PCV Fully Open
RWPS Pump 6 is Auto Running with PCV Fully Open
RWPS Pump 4 is Auto Running with PCV Fully Open
RWPS Pump 7 is Auto Running with PCV Fully Open
RWPS Pump 5 is Auto Running with PCV Fully Open
RWPS Pump 8 is Auto Running with PCV Fully Open
RWPS High Head Number of PCVs Fully Open
RWPS Pump 1 Auto Permissive (In Remote and Auto / Lockout / Local and Not Ready / Local, Ready, and HMI Override)
RWPS Pump 2 Auto Permissive (In Remote and Auto / Lockout / Local and Not Ready / Local, Ready, and HMI Override)
RWPS Pump 3 Auto Permissive (In Remote and Auto / Lockout / Local and Not Ready / Local, Ready, and HMI Override)
RWPS Pump 4 Auto Permissive (In Remote and Auto / Lockout / Local and Not Ready / Local, Ready, and HMI Override)
RWPS Pump 5 Auto Permissive (In Remote and Auto / Lockout / Local and Not Ready / Local, Ready, and HMI Override)
RWPS Pump 6 Auto Permissive (In Remote and Auto / Lockout / Local and Not Ready / Local, Ready, and HMI Override)
RWPS Pump 7 Auto Permissive (In Remote and Auto / Lockout / Local and Not Ready / Local, Ready, and HMI Override)
RWPS Pump 8 Auto Permissive (In Remote and Auto / Lockout / Local and Not Ready / Local, Ready, and HMI Override)
RWPS Pump 9 Auto Permissive (In Remote and Auto / Lockout / Local and Not Ready / Local, Ready, and HMI Override)
RWPS A High Head Pump is in Remote, Auto, Available, Ready and Not Running
RWPS A High Head Pump is in Remote, Auto, Available, and Running
RWPS A High Head Pump is Running
RWPS Pump 1 is Auto Running and PCV is NOT Fully Open
RWPS Pump 2 is Auto Running and PCV is NOT Fully Open
RWPS Pump 9 is Auto Running and PCV is NOT Fully Open
RWPS Pump 3 is Auto Running and PCV is NOT Fully Open
RWPS Pump 5 is Auto Running and PCV is NOT Fully Open
RWPS Pump 7 is Auto Running and PCV is NOT Fully Open
RWPS Pump 4 is Auto Running and PCV is NOT Fully Open
RWPS Pump 6 is Auto Running and PCV is NOT Fully Open
RWPS Pump 8 is Auto Running and PCV is NOT Fully Open
RWPS Any High Head Pump is Running and Valve Is Not Fully Open
RWPS Pump 3 Local and Ready Alarm Flag
RWPS Pump 4 Local and Ready Alarm Flag
RWPS Pump 5 Local And Ready Alarm Flag
RWPS Pump 6 Local And Ready Alarm Flag
RWPS Pump 7 Local And Ready Alarm Flag
RWPS Pump 8 Local And Ready Alarm Flag
RWPS Pump 3 Runtime Totalizer Mode (Hold runtime and reset commands)
RWPS Pump 3 Runtime Totalizer Initialize Command (OUTC to INIT_VALUE)
RWPS Pump 3 Runtime Totalizer Initialize Value
RWPS Pump 3 Runtime Totalizer (outc is the runtime in seconds)
RWPS Pump 3 Runtime Totalizer Output value from Zero to Threshhold then restarts
RWPS Pump 3 Runtime Totalizer Status Information
RWPS Pump 3 Accumulated Runtime
RWPS Pump 4 Runtime Totalizer Mode (Hold runtime and reset commands)
RWPS Pump 4 Runtime Totalizer Initialize Command (OUTC to INIT_VALUE)
RWPS Pump 4 Runtime Totalizer Initialize Value
RWPS Pump 4 Runtime Totalizer (outc is the runtime in seconds)
RWPS Pump 4 Runtime Totalizer Output value from Zero to Threshhold then restarts
RWPS Pump 4 Runtime Totalizer Status Information
RWPS Pump 4 Accumulated Runtime
RWPS Pump 5 Runtime Totalizer Mode (Hold runtime and reset commands)
RWPS Pump 5 Runtime Totalizer Initialize Command (OUTC to INIT_VALUE)
RWPS Pump 5 Runtime Totalizer Initialize Value
RWPS Pump 5 Runtime Totalizer (outc is the runtime in seconds)
RWPS Pump 5 Runtime Totalizer Output value from Zero to Threshhold then restarts
RWPS Pump 5 Runtime Totalizer Status Information
RWPS Pump 5 Accumulated Runtime
RWPS Pump 6 Runtime Totalizer Mode (Hold runtime and reset commands)
RWPS Pump 6 Runtime Totalizer Initialize Command (OUTC to INIT_VALUE)
RWPS Pump 6 Runtime Totalizer Initialize Value
RWPS Pump 6 Runtime Totalizer (outc is the runtime in seconds)
RWPS Pump 6 Runtime Totalizer Output value from Zero to Threshhold then restarts
RWPS Pump 6 Runtime Totalizer Status Information
RWPS Pump 6 Accumulated Runtime
RWPS Pump 7 Runtime Totalizer Mode (Hold runtime and reset commands)
RWPS Pump 7 Runtime Totalizer Initialize Command (OUTC to INIT_VALUE)
RWPS Pump 7 Runtime Totalizer Initialize Value
RWPS Pump 7 Runtime Totalizer (outc is the runtime in seconds)
RWPS Pump 7 Runtime Totalizer Output value from Zero to Threshhold then restarts
RWPS Pump 7 Runtime Totalizer Status Information
RWPS Pump 7 Accumulated Runtime
RWPS Pump 8 Runtime Totalizer Mode (Hold runtime and reset commands)
RWPS Pump 8 Runtime Totalizer Initialize Command (OUTC to INIT_VALUE)
RWPS Pump 8 Runtime Totalizer Initialize Value
RWPS Pump 8 Runtime Totalizer (outc is the runtime in seconds)
RWPS Pump 8 Runtime Totalizer Output value from Zero to Threshhold then restarts
RWPS Pump 8 Runtime Totalizer Status Information
RWPS Pump 8 Accumulated Runtime
RWPS Max Runtime of the High Head Pumps
RWPS Low Head Swap Active
RWPS Low Head Pump Alternation Fail
RWPS Pump 1 Swap Fail
RWPS Pump 2 Swap Fail
RWPS Pump 9 Swap Fail
RWPS Pump 1 Start In Progress (Called to Start and Pump is Not Running or PCV Fully Open)
RWPS Pump 1 Stop In Progress (Called to Stop and Pump is Running or PCV Fully Open)
RWPS Pump 2 Start In Progress (Called to Start and Pump is Not Running or PCV Fully Open)
RWPS Pump 2 Stop In Progress (Called to Stop and Pump is Running or PCV Fully Open)
RWPS Pump 9 Start In Progress (Called to Start and Pump is Not Running or PCV Fully Open)
RWPS Pump 9 Stop In Progress (Called to Stop and Pump is Running or PCV Fully Open)
RWPS Low Head Pump Alternation Reset
RWPS Low Head Pumps Next Start Requested
RWPS Low Head Pump Next Stop Pump Requested
RWPS Pump 1 is Called for Auto Start so Change PID Control from Auto to Manual
RWPS Pump 2 is Called for Auto Start so Change PID Control from Auto to Manual
RWPS Pump 9 is Called for Auto Start so Change PID Control from Auto to Manual
RWPS Low Head Pumps Next Start Unavailable
RWPS Pump 3 is Called for Auto Start so Change PID Control from Auto to Manual
RWPS Pump 4 is Called for Auto Start so Change PID Control from Auto to Manual
RWPS Pump 5 is Called for Auto Start so Change PID Control from Auto to Manual
RWPS Pump 6 is Called for Auto Start so Change PID Control from Auto to Manual
RWPS Pump 7 is Called for Auto Start so Change PID Control from Auto to Manual
RWPS Pump 8 is Called for Auto Start so Change PID Control from Auto to Manual
RWPS 1 Low Head Pump is Required per the Flow Setpoint
RWPS TSR Demand Flow Setpoint - Last Scan
Internal Tag Used to check for Low Head to High Head Transition
Internal Tag Used to check for High Head to Low Head Transition
RWPS Flow Setpoint above 85MGD start Transition from Low Head to High Head Pumps
RWPS Flow Setpoint below 90MGD start Transition from High Head to Low Head Pumps
RWPS 2 Low Head Pumps are Required per the Flow Setpoint
RWPS 3 High Head Pumps are required per the Flow Setpoint
RWPS 4 High Head Pumps are required per the Flow Setpoint
RWPS 5 High Head Pumps are required per the Flow Setpoint
RWPS One Pump is running regardless of High Head or Low Head
RWPS High Head Pumps to Min Speed to Start another Pump
Speed Setpoint passed to the running pumps
RWPS Transition from High Head to Low Head Pumps and High Head Pump is at Transition Speed
RWPS Transition from Low Head to High Head Pumps and Low Head Pump is at Transition Speed
RWPS High Head Pumps Next Auto Start Permissive
RWPS Pump 5 Start Sequence At Min Speed
RWPS High Head AFD Number of Running Pumps At The Time to Call For Another Pump To Run
RWPS Pump 5 Waiting To Start Another Pump Condition Met
RWPS Pump 5 Stop Flag
RWPS High Head Number Of Pump Control Valves Open At Swap Initiate
RWPS High Head Swap Stop First And Fail Reset Counter Enable
RWPS Swap Run A Pump First - Pump 3 Initiate Sequence And Pump 3 FTS
RWPS Pump 3 to Min Speed Init - Stop Sequence
RWPS High Head Pump Swap Sequence Checker - Only 1 Pump Is Running
RWPS Pump 4 to Min Speed Init - Stop Sequence
RWPS Pump 4 Initiates Run First Swap And Fail Reset
RWPS High Head Pump Next Start Pump Priority
RWPS Pump 5 Start Flag
RWPS High Head Pump Next Start Permissive
RWPS All High Head Pumps At Min Speed Init - Stop Sequence
RWPS Swap Stop A Pump First - Pump 4 Initiate Sequence And Pump 4 FTS
RWPS Pump 3 Waiting To Start Another Pump Condition Met
RWPS Pump 4 Stop In Progress (Called to Stop and Pump is Running or PCV Fully Open)
RWPS Pump 5 Initiates Swap Pump - Call Other Pump Start Failure
RWPS Pump 3 Stop Initiate from Swap
RWPS High Head Pump Next Start Request
RWPS High Head Pumps To Min Speed Setpoint Flag Reset
More Than Four High Head Pumps are Running in Auto at Min Speeds - Command to Stop a Pump
RWPS High Head Next Stop Pump Priority
RWPS High Head Pump Timer to hold sequence active to prevent Swap
RWPS Pump 5 Initiates Run First Swap And Fail Reset
RWPS Pump 3 Swap Unplanned Stop Cmd Flag
RWPS High Head Pump Swap Timer Expired
RWPS Pump 4 Start Sequence At Min Speed
RWPS Pump 3 Swap Fail
RWPS Pump 3 Priority
RWPS Pump 4 Swap Fail
RWPS High Head Min Speed Initial Value of PCVs Fully Open
RWPS All Auto Running Pump(s) Start Seq At Min Speed
RWPS Pump 5 Priority
RWPS Pump 3 Priority (Used to determine Next pump to Stop) passed to this tag when Running in Auto and Available with Permissive
RWPS High Head Pump Next Pump Start Request Ton Flag
RWPS Pump 4 Priority (Used to determine Next pump to Start) passed to this tag when Not Running, Ready, in Auto and Available with Permissive
RWPS Pump 4 Alternation Seq Completed
RWPS Pump 4 Stop Flag
RWPS High Head Pump Swap Sequence Checker- More Than 1 Pumps Are Running
RWPS Pump 5 Initiates Swap Pump
RWPS Pump 4 Swap Unplanned Stop Cmd Flag
RWPS Pump 3 Initiates Swap Pump
RWPS High Head Pump Next Start From Swapping Seq
RWPS High Head Pump Next Stop Request
RWPS Swap Stop A Pump First - Pump 5 Initiate Sequence And Pump 5 FTS
RWPS High Head Number of Pump Running In Auto At Time To Swap
RWPS Swap Stop A Pump First - Pump 3 Initiate Sequence And Pump 3 FTS
RWPS Pump 4 Stop Initiate from Swap
RWPS Pump 5 Swap Fail
RWPS Pump 3 Stop Flag
RWPS Pump 4 Initiates Swap Pump
RWPS Pump 5 Stop Initiate from Swap
RWPS Pump 4 Priority (Used to determine Next pump to Stop) passed to this tag when Running in Auto and Available with Permissive
RWPS Swap Run A Pump First - Pump 4 Initiate Sequence And Pump 4 FTS
RWPS Pump 5 Swap Unplanned Stop Cmd Flag
RWPS Pump 4 Waiting To Start Another Pump Condition Met
RWPS Pump 3 Start Sequence At Min Speed
RWPS Pump 3 Initiates Run First Swap And Fail Reset
RWPS Pump 3 Stop In Progress (Called to Stop and Pump is Running or PCV Fully Open)
RWPS Pump 3 Start Flag
RWPS High Head Pump Swap Fail Abort
RWPS High Head Pump Alternation Fail
RWPS High Head Pump Alternation Reset
RWPS Pump 4 Start Flag
RWPS Pump 3 Priority (Used to determine Next pump to Start) passed to this tag when Not Running, Ready, in Auto and Available with Permissive
RWPS Pump 4 Priority
RWPS Pump 5 Priority (Used to determine Next pump to Stop) passed to this tag when Running in Auto and Available with Permissive
RWPS Pump 3 Start In Progress (Called to Start and Pump is Not Running or PCV Fully Open)
RWPS Pump 4 Start In Progress (Called to Start and Pump is Not Running or PCV Fully Open)
RWPS High Head Pump Swap Fail Pump Stop Command Reset
RWPS High Head Swap Next STop Permissive
RWPS High Head Pump Next Start Unavailable
RWPS Pump 5 Stop In Progress (Called to Stop and Pump is Running or PCV Fully Open)
RWPS Pump 5 to Min Speed Init - Stop Sequence
RWPS High Head Pump Swap currently active
RWPS High Head Set Running Pumps To Min Speed From Swap Sequence
RWPS Pump 5 Priority (Used to determine Next pump to Start) passed to this tag when Not Running, Ready, in Auto and Available with Permissive
RWPS Pump 4 Initiates Swap Pump - Call Other Pump Start Failure
RWPS Pump 3 Initiates Swap Pump - Call Other Pump Start Failure
RWPS High Head Pump either Start or Stop Sequence is Active
RWPS Pump 3 Alternation Seq Completed
RWPS Pump 5 Start In Progress (Called to Start and Pump is Not Running or PCV Fully Open)
RWPS Pump 5 Alternation Seq Completed
RWPS High Head Pump Start Waiting Done
RWPS Swap Run A Pump First - Pump 5 Initiate Sequence And Pump 5 FTS
RWPS Pump 6 Alternation Seq Completed
RWPS Pump 6 Initiates Swap Pump
RWPS Pump 6 Initiates Swap Pump - Call Other Pump Start Failure
RWPS Pump 6 Swap Fail
RWPS Pump 7 Alternation Seq Completed
RWPS Pump 7 Initiates Swap Pump
RWPS Pump 7 Initiates Swap Pump - Call Other Pump Start Failure
RWPS Pump 7 Swap Fail
RWPS Pump 8 Alternation Seq Completed
RWPS Pump 8 Initiates Swap Pump
RWPS Pump 8 Initiates Swap Pump - Call Other Pump Start Failure
RWPS Pump 8 Swap Fail
RWPS Swap Run A Pump First - Pump 8 Initiate Sequence And Pump 8 FTS
RWPS Swap Run A Pump First - Pump 7 Initiate Sequence And Pump 7 FTS
RWPS Swap Run A Pump First - Pump 6 Initiate Sequence And Pump 6 FTS
RWPS Swap Stop A Pump First - Pump 6 Initiate Sequence And Pump 6 FTS
RWPS Swap Stop A Pump First - Pump 7 Initiate Sequence And Pump 7 FTS
RWPS Swap Stop A Pump First - Pump 8 Initiate Sequence And Pump 8 FTS
RWPS Pump 8 Stop Flag
RWPS Pump 7 Stop Flag
RWPS Pump 6 Stop Flag
RWPS Pump 6 Swap Unplanned Stop Cmd Flag
RWPS Pump 7 Swap Unplanned Stop Cmd Flag
RWPS Pump 8 Swap Unplanned Stop Cmd Flag
RWPS Pump 6 Initiates Run First Swap And Fail Reset
RWPS Pump 7 Initiates Run First Swap And Fail Reset
RWPS Pump 8 Initiates Run First Swap And Fail Reset
RWPS Pump 8 Start In Progress (Called to Start and Pump is Not Running or PCV Fully Open)
RWPS Pump 8 Stop In Progress (Called to Stop and Pump is Running or PCV Fully Open)
RWPS Pump 7 Start In Progress (Called to Start and Pump is Not Running or PCV Fully Open)
RWPS Pump 7 Stop In Progress (Called to Stop and Pump is Running or PCV Fully Open)
RWPS Pump 6 Start In Progress (Called to Start and Pump is Not Running or PCV Fully Open)
RWPS Pump 6 Stop In Progress (Called to Stop and Pump is Running or PCV Fully Open)
RWPS Pump 3 Swap Pump Next Stop Permissive
RWPS Pump 4 Swap Pump Next Stop Permissive
RWPS Pump 5 Swap Pump Next Stop Permissive
RWPS Pump 6 Swap Pump Next Stop Permissive
RWPS Pump 7 Swap Pump Next Stop Permissive
RWPS Pump 8 Swap Pump Next Stop Permissive
RWPS Pump 6 Stop Initiate from Swap
RWPS Pump 7 Stop Initiate from Swap
RWPS Pump 8 Stop Initiate from Swap
RWPS Pump 6 Priority
RWPS Pump 6 Priority (Used to determine Next pump to Start) passed to this tag when Not Running, Ready, in Auto and Available with Permissive
RWPS Pump 7 Priority
RWPS Pump 7 Priority (Used to determine Next pump to Start) passed to this tag when Not Running, Ready, in Auto and Available with Permissive
RWPS Pump 8 Priority
RWPS Pump 8 Priority (Used to determine Next pump to Start) passed to this tag when Not Running, Ready, in Auto and Available with Permissive
RWPS Pump 8 Waiting To Start Another Pump Condition Met
RWPS Pump 7 Waiting To Start Another Pump Condition Met
RWPS Pump 6 Waiting To Start Another Pump Condition Met
Internal Tag for High Head Pumps used for Next Start Requests
RWPS Pump 6 Start Sequence At Min Speed
RWPS Pump 7 Start Sequence At Min Speed
RWPS Pump 8 Start Sequence At Min Speed
RWPS Pump 6 Start Flag
RWPS Pump 7 Start Flag
RWPS Pump 8 Start Flag
RWPS Pump 6 Priority (Used to determine Next pump to Stop) passed to this tag when Running in Auto and Available with Permissive
RWPS Pump 7 Priority (Used to determine Next pump to Stop) passed to this tag when Running in Auto and Available with Permissive
RWPS Pump 8 Priority (Used to determine Next pump to Stop) passed to this tag when Running in Auto and Available with Permissive
RWPS Pump 6 to Min Speed Init - Stop Sequence
RWPS Pump 7 to Min Speed Init - Stop Sequence
RWPS Pump 8 to Min Speed Init - Stop Sequence
Reset Point Mapping of Simulation Logic
Simulation Time for a Pump for Startup/Shutdown
RWPS Pump 1 Ramp Rate Simulation Parameters
Simulation tag used for all valve travel times
RWPS Pump 2 Ramp Rate Simulation Parameters
RWPS Pump 3 Ramp Rate Simulation Parameters
RWPS Pump 4 Ramp Rate Simulation Parameters
RWPS Pump 5 Ramp Rate Simulation Parameters
RWPS Pump 6 Ramp Rate Simulation Parameters
RWPS Pump 7 Ramp Rate Simulation Parameters
RWPS Pump 8 Ramp Rate Simulation Parameters
RWPS Pump 9 Ramp Rate Simulation Parameters
Spare
Spare
Pump 1 Low Cooling Flow - Interlock Pump
Pump 2 Low Cooling Flow - Interlock Pump
Pump 3 Low Cooling Flow - Interlock Pump
Pump 4 Low Cooling Flow - Interlock Pump
Pump 5 Low Cooling Flow - Interlock Pump
Pump 6 Low Cooling Flow - Interlock Pump
Pump 7 Low Cooling Flow - Interlock Pump
Pump 8 Low Cooling Flow - Interlock Pump
Pump 9 Low Cooling Flow - Interlock Pump
RWPS AFD Pump 1 Speed
224
0
0
0
1
0
17746
85.9125
85.9125
0.0
100.0
4000.0
20000.0
0.0
0.0
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
5.0
5.0
2
0
0
0
0
0
1
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS AFD Pump 2 Speed
224
0
0
0
1
0
3999
-0.00625
-0.00625
0.0
100.0
4000.0
20000.0
0.0
0.0
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
5.0
5.0
2
0
0
0
0
0
1
0
5.0
5.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS AFD PUMP 3 SPEED
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS AFD PUMP 4 SPEED
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS AFD PUMP 5 SPEED
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS AFD PUMP 6 SPEED
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS AFD PUMP 7 SPEED
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS AFD PUMP 8 SPEED
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS AFD Pump 9 Speed
224
0
0
0
1
0
3996
-0.025
-0.025
0.0
100.0
4000.0
20000.0
0.0
0.0
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
5.0
5.0
2
0
0
0
0
0
1
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 1 Cooling Water Flow
224
0
2
0
1
0
7607
51.85062
51.85062
0.0
230.0
4000.0
20000.0
0.0
0.0
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
2.197960E+07
2
0
0
0
0
0
750
0
15.0
15.0
2
0
0
0
0
0
500
0
15.0
15.0
2
0
0
0
0
0
500
0
15.0
15.0
2
0
0
0
0
0
750
0
15.0
15.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
15.0
15.0
2
0
0
0
0
0
1
0
15.0
15.0
2
0
0
0
0
0
250
0
15.0
15.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
51.85062
230.0
0.0
33378.22
77784.49
2.197960E+07
306
2.194623E+07
2.197960E+07
0.0
2021
3
31
7
43
0
300.0
32.72378
0.1728354
33345.5
0.0
189
-1.0
0
RWPS Pump 2 Cooling Water Flow
224
0
2
0
1
0
3980
-0.2875
-0.2875
0.0
230.0
4000.0
20000.0
0.0
0.0
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
1.727722E+07
2
0
0
0
0
0
750
0
15.0
15.0
2
0
0
0
0
0
500
0
15.0
15.0
2
0
0
0
0
0
500
0
15.0
15.0
2
0
0
0
0
0
750
0
15.0
15.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
15.0
15.0
2
0
0
0
0
0
1
0
15.0
15.0
2
0
0
0
0
0
250
0
15.0
15.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
1
-0.2875
230.0
0.0
0.0
0.0
1.727722E+07
306
1.727722E+07
1.727722E+07
0.0
0
0
0
0
0
0
300.0
0.0
-0.0009583333
0.0
0.0
0
-1.0
0
RWPS Pump 3 Cooling Water Flow
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 4 Cooling Water Flow
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 5 Cooling Water Flow
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 6 Cooling Water Flow
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 7 Cooling Water Flow
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 8 Cooling Water Flow
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 9 Cooling Water Flow
224
0
2
0
1
0
3986
-0.1925
-0.1925
0.0
220.0
4000.0
20000.0
0.0
0.0
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
4.432676E+07
2
0
0
0
0
0
750
0
15.0
15.0
2
0
0
0
0
0
500
0
15.0
15.0
2
0
0
0
0
0
500
0
15.0
15.0
2
0
0
0
0
0
750
0
15.0
15.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
15.0
15.0
2
0
0
0
0
0
1
0
15.0
15.0
2
0
0
0
0
0
250
0
15.0
15.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
1
-0.1925
220.0
0.0
0.0
0.0
4.432676E+07
306
4.432676E+07
4.432676E+07
0.0
0
0
0
0
0
0
300.0
0.0
-0.0006416666
0.0
0.0
0
-1.0
0
RWPS Reservoir Valve West Side Position Indication
224
0
0
0
1
0
4057
0.35625
0.35625
0.0
100.0
4000.0
20000.0
0.0
0.0
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Reservoir Valve East Side Position Indication
224
0
0
0
1
0
4050
0.3125
0.3125
0.0
100.0
4000.0
20000.0
0.0
0.0
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Flow To Reservoir Release Flow
224
0
2
0
1
0
3999
-0.003125
-0.003125
0.0
50.0
4000.0
20000.0
0.0
0.0
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
1.893573E+08
2
0
0
0
0
0
750
0
15.0
15.0
2
0
0
0
0
0
500
0
15.0
15.0
2
0
0
0
0
0
500
0
15.0
15.0
2
0
0
0
0
0
750
0
15.0
15.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
15.0
15.0
2
0
0
0
0
0
1
0
15.0
15.0
2
0
0
0
0
0
250
0
15.0
15.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
-0.003125
50.0
0.0
0.0
0.0
1.893573E+08
306
1.893573E+08
1.893573E+08
0.0
0
0
0
0
0
0
5.0
0.0
-0.000625
0.0
0.0
76
-1.0
0
RWPS Pump 1 Control Valve Position Feedback
224
0
0
0
1
0
19988
99.925
99.925
0.0
100.0
4000.0
20000.0
0.0
0.0
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 2 Control Valve Position Feedback
224
0
0
0
1
0
4014
0.0875
0.0875
0.0
100.0
4000.0
20000.0
0.0
0.0
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 3 Control Valve Position Feedback
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 4 Control Valve Position Feedback
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 5 Control Valve Position Feedback
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 6 Control Valve Position Feedback
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 7 Control Valve Position Feedback
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 8 Control Valve Position Feedback
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 9 Control Valve Position Feedback
224
0
0
0
1
0
4021
0.13125
0.13125
0.0
100.0
4000.0
20000.0
0.0
0.0
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Motor 1 X-Direction Vibration Drive End Bearing
230
0
0
0
2
0
4214
0.02675
0.02675
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
180.0
180.0
2
0
0
0
0
0
500
0
180.0
180.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Motor 1 Y-Direction Vibration Drive End Bearing
230
0
0
0
2
0
4200
0.025
0.025
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
180.0
180.0
2
0
0
0
0
0
500
0
180.0
180.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Motor 1 X-Direction Vibration Non-Drive End Bearing
230
0
0
0
2
0
4142
0.01775
0.01775
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
180.0
180.0
2
0
0
0
0
0
500
0
180.0
180.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Motor 1 Y-Direction Vibration Non-Drive End Bearing
230
0
0
0
2
0
4164
0.0205
0.0205
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
180.0
180.0
2
0
0
0
0
0
500
0
180.0
180.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Motor 2 X-Direction Vibration Drive End Bearing
230
0
0
0
2
0
4132
0.0165
0.0165
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
Rwps Motor 2 Y-Direction Vibration Drive End Bearing
230
0
0
0
2
0
4154
0.01925
0.01925
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
Rwps Motor 2 X-Direction Vibration Non-Drive End Bearing
230
0
0
0
2
0
4191
0.023875
0.023875
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
Rwps Motor 2 Y-Direction Vibration Non-Drive End Bearing
230
0
0
0
2
0
4184
0.023
0.023
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Motor 3 X-Direction Vibration Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 3 Y-Direction Vibration Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 3 X-Direction Vibration Non-Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 3 Y-Direction Vibration Non-Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 4 X-Direction Vibration Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 4 Y-Direction Vibration Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 4 X-Direction Vibration Non-Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 4 Y-Direction Vibration Non-Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 5 X-Direction Vibration Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 5 Y-Direction Vibration Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 5 X-Direction Vibration Non-Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 5 Y-Direction Vibration Non-Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 6 X-Direction Vibration Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 6 Y-Direction Vibration Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 6 X-Direction Vibration Non-Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 6 Y-Direction Vibration Non-Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 7 X-Direction Vibration Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 7 Y-Direction Vibration Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 7 X-Direction Vibration Non-Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 7 Y-Direction Vibration Non-Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 8 X-Direction Vibration Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 8 Y-Direction Vibration Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 8 X-Direction Vibration Non-Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 8 Y-Direction Vibration Non-Drive End Bearing
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Motor 9 X-Direction Vibration Drive End Bearing
230
420
0
0
2
0
4263
0.032875
0.032875
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
210
4
4160
0
0
8204
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
8204
RWPS Motor 9 Y-Direction Vibration Drive End Bearing
230
0
0
0
2
0
4113
0.014125
0.014125
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Motor 9 X-Direction Vibration Non-Drive End Bearing
230
0
0
0
2
0
4139
0.017375
0.017375
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Motor 9 Y-Direction Vibration Non-Drive End Bearing
230
0
0
0
2
0
4167
0.020875
0.020875
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS West Suction Pressure
224
0
0
0
1
0
14478
32.74375
32.74375
0.0
50.0
4000.0
20000.0
40.0
30.0
20.0
10.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS East Suction Pressure
224
0
0
0
1
0
14506
32.83125
32.83125
0.0
50.0
4000.0
20000.0
40.0
30.0
20.0
10.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 1 Discharge Pressure
224
0
0
0
1
0
10182
115.9125
115.9125
0.0
300.0
4000.0
20000.0
230.0
157.0
105.0
52.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
-52.5
210.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
5.0
0.0
-10.5
0.0
0.0
0
-1.0
0
RWPS Pump 2 Discharge Pressure
224
0
0
0
1
0
5674
31.3875
31.3875
0.0
300.0
4000.0
20000.0
230.0
190.0
90.0
50.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
-1250.0
5000.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
5.0
0.0
-250.0
0.0
0.0
0
-1.0
0
RWPS Pump 3 Discharge Pressure
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 4 Discharge Pressure
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 5 Discharge Pressure
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 6 Discharge Pressure
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 7 Discharge Pressure
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 8 Discharge Pressure
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 9 Discharge Pressure
224
0
0
0
1
0
5681
31.51875
31.51875
0.0
300.0
4000.0
20000.0
230.0
220.0
80.0
70.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Discharge Pressure
254
0
0
0
1
0
10279
117.7312
117.7312
0.0
300.0
4000.0
20000.0
290.0
275.0
100.0
90.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
500
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 1 X-Direction Vibration (Ce)
230
0
0
0
2
0
4599
0.074875
0.074875
0.0
2.0
4000.0
20000.0
0.28
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
180.0
180.0
2
0
0
0
0
0
750
0
180.0
180.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 1 Y-Direction Vibration (Ce)
230
0
0
0
2
0
5330
0.16625
0.16625
0.0
2.0
4000.0
20000.0
0.4
0.25
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
180.0
180.0
2
0
0
0
0
0
750
0
180.0
180.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 1 X-Direction Vibration (Obe)
230
0
0
0
2
0
4461
0.057625
0.057625
0.0
2.0
4000.0
20000.0
0.28
0.2
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
180.0
180.0
2
0
0
0
0
0
750
0
180.0
180.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 1 Y-Direction Vibration (Obe)
8422
1184
0
0
2
0
5680
0.21
0.21
0.0
2.0
4000.0
20000.0
0.28
0.2
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
180.0
180.0
91
0
4160
0
0
8496
750
0
180.0
0.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
8496
RWPS Pump 1 Z-Direction Vibration (Obe)
8422
416
0
0
2
0
4575
0.071875
0.071875
0.0
2.0
4000.0
20000.0
0.28
0.2
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
210
0
4160
0
0
8240
750
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
8240
RWPS Pump 2 X-Direction Vibration (Ce)
230
0
0
0
2
0
4138
0.01725
0.01725
0.0
2.0
4000.0
20000.0
0.28
0.2
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
Rwps Pump 2 Y-Direction Vibration (Ce)
230
0
0
0
2
0
4245
0.030625
0.030625
0.0
2.0
4000.0
20000.0
0.28
0.2
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
Rwps Pump 2 X-Direction Vibration (Obe)
230
0
0
0
2
0
4312
0.039
0.039
0.0
2.0
4000.0
20000.0
0.28
0.2
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
Rwps Pump 2 Y-Direction Vibration (Obe)
230
0
0
0
2
0
4108
0.0135
0.0135
0.0
2.0
4000.0
20000.0
0.28
0.2
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
Rwps Pump 2 Z-Direction Vibration (Obe)
230
8357
0
0
2
0
2035
-0.245625
-0.245625
0.0
2.0
4000.0
20000.0
0.28
0.2
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
90
4
4160
0
0
8468
250
0
5.0
0.0
2
0
0
0
0
0
1
0
30.0
30.0
210
4
4160
0
0
8204
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
8468
RWPS Pump 3 X-Direction Vibration (Ce)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 3 Y-Direction Vibration (Ce)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 3 X-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 3 Y-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 3 Z-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 4 X-Direction Vibration (Ce)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 4 Y-Direction Vibration (Ce)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 4 X-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 4 Y-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 4 Z-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 5 X-Direction Vibration (Ce)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 5 Y-Direction Vibration (Ce)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 5 X-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 5 Y-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 5 Z-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 6 X-Direction Vibration (Ce)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 6 Y-Direction Vibration (Ce)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 6 X-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 6 Y-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 6 Z-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 7 X-Direction Vibration (Ce)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 7 Y-Direction Vibration (Ce)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 7 X-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 7 Y-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 7 Z-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 8 X-Direction Vibration (Ce)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 8 Y-Direction Vibration (Ce)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 8 X-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 8 Y-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 8 Z-Direction Vibration (Obe)
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
0.0
0
RWPS Pump 9 X-Direction Vibration (Ce)
230
0
0
0
2
0
4129
0.016125
0.016125
0.0
2.0
4000.0
20000.0
0.28
0.2
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 9 Y-Direction Vibration (Ce)
230
0
0
0
2
0
4054
0.00675
0.00675
0.0
2.0
4000.0
20000.0
0.28
0.2
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 9 X-Direction Vibration (Obe)
230
0
0
0
2
0
4098
0.01225
0.01225
0.0
2.0
4000.0
20000.0
0.28
0.2
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 9 Y-Direction Vibration (Obe)
230
0
0
0
2
0
4141
0.017625
0.017625
0.0
2.0
4000.0
20000.0
0.28
0.2
1.0
0.5
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 9 Z-Direction Vibration (Obe)
230
0
0
0
2
0
4080
0.01
0.01
0.0
2.0
4000.0
20000.0
0.28
0.2
0.0
0.0
3100.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
1000
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Scada Room Ambient Temperature
224
0
0
0
1
0
12795
73.36625
73.36625
14.0
122.0
4000.0
20000.0
0.0
0.0
0.0
0.0
2800.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Electrical Room Ambient Temperature
224
0
0
0
1
0
11951
67.66925
67.66925
14.0
122.0
4000.0
20000.0
0.0
0.0
0.0
0.0
2800.0
20500.0
3500.0
0.0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0
0.0
0.0
0.0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0
-1.0
0
RWPS Pump 1 Cooling Water Flow Failure
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
60.0
60.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
Pump 1 Motor Seal Leak
1
0
0
0
0
0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 1 E. Stop
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 1 MPR Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 1 High Rtd Temp
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 1 MPR Trip
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 1 AFD Trip
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 1 AFD E. Stop
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 2 Cooling Water Flow Failure
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
60.0
60.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
Pump 2 Motor Seal Leak
1
0
0
0
0
0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 2 E. Stop
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 2 MPR Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 2 High Rtd Temp
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 2 MPR Trip
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 2 AFD Trip
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 2 AFD E. Stop
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 3 Cooling Water Flow Failure
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 3 TEWAC Motor Leak Sensor
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 3 E. STOP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 3 MPR ALARM
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 3 HIGH RTD TEMP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 3 MPR TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 3 AFD TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 3 AFD E. STOP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 4 COOLING WATER FLOW FAILURE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 4 TEWAC MOTOR LEAK SENSOR
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 4 E. STOP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 4 MPR ALARM
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 4 HIGH RTD TEMP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 4 MPR TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 4 AFD TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 4 AFD E. STOP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 5 COOLING WATER FLOW FAILURE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 5 TEWAC MOTOR LEAK SENSOR
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 5 E. STOP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 5 MPR ALARM
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 5 HIGH RTD TEMP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 5 MPR TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 5 AFD TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 5 AFD E. STOP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 6 COOLING WATER FLOW FAILURE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 6 TEWAC MOTOR LEAK SENSOR
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 6 E. STOP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 6 MPR ALARM
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 6 HIGH RTD TEMP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 6 MPR TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 6 AFD TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 6 AFD E. STOP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 7 COOLING WATER FLOW FAILURE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 7 TEWAC MOTOR LEAK SENSOR
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 7 E. STOP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 7 MPR ALARM
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 7 HIGH RTD TEMP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 7 MPR TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 7 AFD TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 7 AFD E. STOP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 8 COOLING WATER FLOW FAILURE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 8 TEWAC MOTOR LEAK SENSOR
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 8 E. STOP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 8 MPR ALARM
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 8 HIGH RTD TEMP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 8 MPR TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 8 AFD TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 8 AFD E. STOP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 9 Cooling Water Flow Failure
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
60.0
60.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
Pump 9 Motor Seal Leak
1
0
0
0
0
0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
0
0
5.0
5.0
5.0
0
RWPS Pump 9 E. Stop
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 9 MPR Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 9 High Rtd Temp
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 9 MPR Trip
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 9 AFD Trip
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 9 AFD E. Stop
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Switchgear 0112-1 Transfer Failure
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Switchgear 0112-1 Common Alarm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Switchgear 0112-2 Transfer Failure
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Switchgear 0112-2 Common Alarm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS 480V Switchgear Transfer Failure
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS 480V Switchgear Common Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Elevator Common Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Elevator Common Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Elevator Pit Common High Level Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Northwest Sump Pump Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Northwest Sump Pump Control Power Failure
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Southwest By Pump 1 Sump Pump Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Southwest By Pump 1 Sump Pump Control Power Failure
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Southwest By Pump 4 Sump Pump Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Southwest By Pump 4 Sump Pump Control Power Failure
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Alcove Sump Pump Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Alcove Sump Pump Control Power Failure
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Alcove Sump Pump Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Alcove Sump Pump Control Power Failure
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Southeast Sump Pump Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Southeast Sump Pump Control Power Failure
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Northeast Sump Pump Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Northeast Sump Pump Control Power Failure
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Elevator Sump Pump Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Elevator Sump Pump Control Power Failure
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Elevator Sump Pump Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Elevator Sump Pump Control Power Failure
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Secondary Dewatering High Level Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Secondary Dewatering Pump A Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Secondary Dewatering SSRVS A Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Secondary Dewatering Pump B Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Secondary Dewatering SSRVSB Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Secondary Dewatering Control Power Failure
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Secondary Dewatering High Level Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Secondary Dewatering Pump C Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Secondary Dewatering SSRVSC Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Secondary Dewatering Pump D Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Secondary Dewatering SSRVSD Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Secondary Dewatering Control Power Failure
1
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Intake Maintenance Dewatering Pump Fault
-30195
16
0
0
0
0
91
0
4160
0
0
8496
750
0
5.0
0.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
8496
RWPS Discharge Maintenance Dewatering Pump Fault
-30195
16
0
0
0
0
91
0
4160
0
0
8496
750
0
5.0
0.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
8496
RWPS West Dam Collector Wet Well High Level Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Dam Collector Wet Well High-High Level Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Dam Collector Pump Control Power Failure
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Dam Collector Pump A Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Dam Collector Pump B Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Dam Collector Wet Well High Level Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Dam Collector Wet Well High-High Level Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Dam Collector Pump Control Power Failure
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Dam Collector Pump A Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Dam Collector Pump B Fault
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS To Reservoir West Sleeve Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS To Reservoir East Sleeve Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
Active Harmonic Filter Common Alarm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
Active Harmonic Filter Common Alarm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS West Intake Valve High Torque
4
0
0
0
0
0
2
0
2
0
0
0
1000
0
5.0
5.0
2
0
2
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Suction Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Intake Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Suction Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 1 Suction Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 1 Control Valve Failure
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 1 PCV Not Ready Alarm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 1 Discharge Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 2 Suction Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 2 Control Valve Failure
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 2 PCV Not Ready Alarm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 2 Discharge Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 3 Suction Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 3 Control Valve Failure
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 3 CONTROL VALVE PANEL TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 3 CONTROL VALVE PANEL WARNING
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 3 Discharge Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 3 Suction Bypass Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 4 Suction Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 4 Control Valve Failure
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 4 CONTROL VALVE PANEL TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 4 CONTROL VALVE PANEL WARNING
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 4 Discharge Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 4 Suction Bypass Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 5 Suction Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 5 Control Valve Failure
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 5 CONTROL VALVE PANEL TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 5 CONTROL VALVE PANEL WARNING
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 5 Discharge Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 5 Suction Bypass Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 6 Suction Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 6 Control Valve Failure
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 6 CONTROL VALVE PANEL TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 6 CONTROL VALVE PANEL WARNING
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 6 Discharge Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 6 Suction Bypass Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 7 Suction Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 7 Control Valve Failure
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 7 CONTROL VALVE PANEL TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 7 CONTROL VALVE PANEL WARNING
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 7 Discharge Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 7 Suction Bypass Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 8 Suction Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 8 Control Valve Failure
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 8 CONTROL VALVE PANEL TRIP
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PUMP 8 CONTROL VALVE PANEL WARNING
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 8 Discharge Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 8 Suction Bypass Valve High Torque
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 9 Suction Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 9 Control Valve Failure
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 9 PCV Not Ready Alarm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 9 Discharge Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS To Reservoir West Suction Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS To Reservoir West Discharge Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS To Reservoir East Suction Valve High Torque
96
0
0
0
0
0
512
0
0
0
0
0
1000
0
5.0
0.0
512
0
0
0
0
0
250
0
5.0
0.0
0.0
0
RWPS To Reservoir East Discharge Valve High Torque
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Stand-By Generator Low Fuel
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Stand-By Generator Low Oil Pressure
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Stand-By Generator Over Speed
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Stand-By Generator High Water Teperature
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Stand-By Generator Common Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Stand-By Generator Battery Sys Malfunction
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (Chiller SYS Com) Cooling Water No Flow
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (AUH SYS Com) Condensate Overflow Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (FCU Com) Filter High Diff Pressure Alarm
-30195
16
0
0
0
0
91
0
4160
0
0
8496
750
0
5.0
0.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
8496
RWPS (AUH SYS Com) High Temperature Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (Chiller SYS Com) Chilled Water Supply High Temp Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (Doas SYS Com) Supply Air High Temp
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (AUH SYS Com) Freeze Protection Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (Doas SYS Com) Supply Air Low Temp
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Emergency Hvac Shutdown
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (AUH SYS Com) Fan Failure Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (AUH SYS Com) Space Temperature Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (AUH SYS Com) Dirty Filter Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (AUH SYS Com) Smoke Detector Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (Chiller SYS Com) Proof Of Flow
-30195
16
0
0
0
0
91
0
4160
0
0
8496
750
0
5.0
0.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
8496
RWPS (Chiller SYS Com) Chilled Water Pump Failure
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (Chiller SYS Com) Chiller Failure Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (Doas SYS Com) Supply Fan Failure
-30195
16
0
0
0
0
91
0
4160
0
0
8496
750
0
5.0
0.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
8496
RWPS (FCU Com) Fan Failure Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (EF Com) Fan Failure Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS (SF Com) Fan Failure Alarm
4
0
0
0
0
0
2
0
0
0
0
0
750
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS West Pump Room High Level Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Pump Room High Level Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Net Panel DC Power Ok
1
0
0
0
0
0
2
0
2
0
0
0
1
0
5.0
5.0
2
0
2
0
0
0
1
0
5.0
5.0
5.0
0
RWPS Net Panel Door Open
-30195
16
0
0
0
0
91
0
4160
0
0
8456
1
0
5.0
0.0
2
0
0
0
0
0
1
0
5.0
5.0
5.0
8456
PFCC Inhibit Signal Active Warning
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS West Suction Low Pressure Lockout
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Suction Low Pressure Lockout
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Plc Panel DC Power Ok
1
0
0
0
0
0
2
0
0
0
0
0
1
0
5.0
5.0
2
0
0
0
0
0
1
0
5.0
5.0
5.0
0
RWPS Plc Panel Door Open
4
0
0
0
0
0
2
0
0
0
0
0
1
0
5.0
5.0
2
0
0
0
0
0
1
0
5.0
5.0
5.0
0
RWPS Pump 1 Suction Pressure Loss
4
0
0
0
0
0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 2 Suction Pressure Loss
4
0
0
0
0
0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Pump 3 Suction Pressure Loss
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 4 Suction Pressure Loss
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 5 Suction Pressure Loss
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 6 Suction Pressure Loss
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 7 Suction Pressure Loss
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 8 Suction Pressure Loss
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 9 Suction Pressure Loss
4
0
0
0
0
0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Recloser 1 Trip
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Recloser 2 Trip
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Recloser 3 Trip
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Recloser 4 Trip
4
0
0
0
0
0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Electrical Building Smoke Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
0.0
0.0
2
0
0
0
0
0
750
0
0.0
0.0
0.0
0
RWPS West Pump Room Smoke Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
0.0
0.0
2
0
0
0
0
0
750
0
0.0
0.0
0.0
0
RWPS East Pump Room Smoke Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
0.0
0.0
2
0
0
0
0
0
750
0
0.0
0.0
0.0
0
RWPS West Stairwell Smoke Detected
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
0.0
0.0
2
0
0
0
0
0
750
0
0.0
0.0
0.0
0
RWPS East Stairwell Smoke Detected
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
0.0
0.0
2
0
0
0
0
0
750
0
0.0
0.0
0.0
0
RWPS Swb-0112-1 SPD Maintenance Alarm
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Swb-0112-2 SPD Maintenance Alarm
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS LP-0112-3 SPD Maintenance Alarm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Swg-0112-3A SPD Maintenance Alarm
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Swg-0112-3B SPD Maintenance Alarm
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Pp-0112-1 SPD Maintenance Alarm
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS LP-0112-4 SPD Maintenance Alarm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pp-0112-2 SPD Maintenance Alarm
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Lp-0112-1 SPD Maintenance Alarm
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Pp-0113-1 SPD Maintenance Alarm
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Pp-0113-2 SPD Maintenance Alarm
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Scada Room Heat Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
0.0
0.0
2
0
0
0
0
0
750
0
0.0
0.0
0.0
0
RWPS Electrical Building Heat Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
0.0
0.0
2
0
0
0
0
0
750
0
0.0
0.0
0.0
0
RWPS West Pump Room Heat Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
0.0
0.0
2
0
0
0
0
0
750
0
0.0
0.0
0.0
0
RWPS East Pump Room Heat Alarm
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
0.0
0.0
2
0
0
0
0
0
750
0
0.0
0.0
0.0
0
RWPS West Hoistway Heat Detector
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
0.0
0.0
2
0
0
0
0
0
750
0
0.0
0.0
0.0
0
RWPS East Hoistway Heat Detector
4
0
0
0
0
0
2
0
0
0
0
0
1000
0
0.0
0.0
2
0
0
0
0
0
750
0
0.0
0.0
0.0
0
RWPS Substation Transformer 1 Low Oil Level
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Substation Transformer 1 Oil High Temperature
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Substation Transformer 1 Winding High Temperature
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Substation Transformer 1 Pressure Relief Device Activation
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Substation Transformer 2 Low Oil Level
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Substation Transformer 2 Oil High Temperature
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Substation Transformer 2 Winding High Temperature
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Substation Transformer 2 Pressure Relief Device Activation
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Scada UPS Panel UPS Alarm
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Scada UPS Panel Door Open
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Security UPS Panel UPS Alarm
-30200
16
0
0
0
0
91
0
4160
0
0
8464
250
0
1.0
0.0
2
0
0
0
0
0
250
0
1.0
1.0
1.0
8464
RWPS Security UPS Panel Door Open
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Electrical Building Intrusion
-30195
16
0
0
0
0
91
0
4160
0
0
8464
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
8464
RWPS West Pump Hatch Open
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS West Alcove Hatch Open
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS East Pump Hatch Open
4
0
0
0
0
0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS East Alcove Hatch Open
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 3 Low Oil Level - 'LL-1'
4
0
0
0
0
0
2
0
8
0
0
0
250
1
0.0
0.0
2
0
8
0
0
0
250
1
0.0
0.0
0.0
0
RWPS Substation Transformer 3 Oil High Temperature - 'LT-1 (S-1)'
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 3 Winding High Temperature - 'WT1-1 (S-2)
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 3 Pressure Relief Device Activation - 'PRD-1'
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 4 Low Oil Level
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 4 Oil High Teperature
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 4 Winding High Teperature
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 4 Pressure Relief Device Activation
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 5 Low Oil Level
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 5 Oil High Teperature
4
0
0
0
0
0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
5.0
0
RWPS Substation Transformer 5 Winding High Teperature
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 5 Pressure Relief Device Activation
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 6 Low Oil Level
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 6 Oil High Teperature
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 6 Winding High Teperature
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS Substation Transformer 6 Pressure Relief Device Activation
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
250
0
0.0
0.0
0.0
0
RWPS PLC Communication To East Micro Pump Station Failure
4
0
0
0
0
0
2
0
0
0
0
0
0
0
0.0
0.0
514
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PLC Communication To Easton Pump 1 Failure
1
0
0
0
0
0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PLC Communication To Easton Pump 2 Failure
1
0
0
0
0
0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PLC Communication To Easton Pump 9 Failure
1
0
0
0
0
0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PLC Communication To Meter Vault PLC Failure
4
0
0
0
0
0
2
0
0
0
0
0
250
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PLC Communication To SEL710 Pump 1 Failure
1
0
0
0
0
0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PLC Communication To SEL 710 Pump 2 Failure
1
0
0
0
0
0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PLC Communication To SEL 710 Pump 9 Failure
1
0
0
0
0
0
2
0
0
0
0
0
0
0
0.0
0.0
2
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PLC Communication To TSR PLC Failure
1
0
0
0
0
0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS PLC Communication To East Micro Pump Station Failure
4
0
0
0
0
0
514
0
0
0
0
0
0
0
0.0
0.0
514
0
0
0
0
0
0
0
0.0
0.0
0.0
0
RWPS Pump 1
-29308
-16384
0
0
0
0
10
21
5360
43
23
55
341
0
0
2021
4
7
8
47
27
2021
4
7
7
55
35
6
3
2024
10
22
39
0.0
0.0
999999.0
17706.34
2
0
0
0
0
0
1000
0
300.0
300.0
2
0
0
0
0
0
1000
0
600.0
600.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
60.0
60.0
0
86.91462
84.41462
60.0
85.66462
85.9125
100.0
83.0
85.66462
2.5
85.66462
0
RWPS Pump 2
-29564
1
0
0
0
0
0
0
3721
32
0
0
438
0
0
2022
9
8
17
46
1
0
0
0
0
0
0
2
4
2024
17
50
35
0.0
0.0
999999.0
17280.0
2
0
0
0
0
0
1000
0
300.0
300.0
2
0
0
0
0
0
1000
0
500.0
500.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
60.0
60.0
0
84.25
81.75
60.0
83.0
-0.00625
100.0
83.0
83.0
2.5
83.0
0
RWPS Pump 3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
RWPS Pump 4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
RWPS Pump 5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
RWPS Pump 6
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
RWPS Pump 7
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
RWPS Pump 8
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
RWPS Pump 9
-29564
-32768
0
0
0
0
0
0
5669
2
0
0
480
0
0
2023
6
13
8
27
2
0
0
0
0
0
0
5
29
2024
13
29
22
0.0
0.0
999999.0
17280.0
2
0
0
0
0
0
1000
0
300.0
300.0
2
0
0
0
0
0
1000
0
600.0
600.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
250
0
60.0
60.0
0
84.25
81.75
60.0
83.0
-0.025
100.0
83.0
83.0
2.5
83.0
0
RWPS West Intake Valve
79
0
4096
0
0
0
0
999999.0
50
0
0
0
0
0
0
0
6
13
2023
0
0
0
2
0
0
0
0
0
1000
0
720.0
720.0
2
0
0
0
0
0
1000
0
720.0
720.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS West Suction Valve
79
0
4096
0
0
0
0
999999.0
41
0
0
0
0
0
0
0
1
1
1990
0
0
0
2
0
0
0
0
0
1000
0
720.0
720.0
2
0
0
0
0
0
1000
0
720.0
720.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS East Intake Valve
79
0
0
0
0
0
0
999999.0
12
0
0
0
0
0
0
0
9
15
2022
0
0
0
2
0
0
0
0
0
1000
0
720.0
720.0
2
0
0
0
0
0
1000
0
720.0
720.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS East Suction Valve
79
0
4096
0
0
0
0
999999.0
8
0
0
0
0
0
0
0
1
1
1990
0
0
0
2
0
0
0
0
0
1000
0
720.0
720.0
2
0
0
0
0
0
1000
0
720.0
720.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS Pump 1 Suction Valve
79
0
4096
0
0
0
0
999999.0
23
0
0
0
0
0
0
0
1
1
1990
0
0
0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS Pump 1 Discharge Valve
79
0
0
0
0
0
0
999999.0
52
0
0
0
0
0
0
0
3
20
2023
0
0
0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS Pump 2 Suction Valve
79
0
4096
0
0
0
0
999999.0
22
0
0
0
0
0
0
0
1
1
1990
0
0
0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS Pump 2 Discharge Valve
79
0
4096
0
0
0
0
999999.0
49
0
0
0
0
0
0
0
3
20
2023
0
0
0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS Pump 3 Suction Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 3 Discharge Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 3 Suction Bypass Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 4 Suction Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 4 Discharge Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 4 Suction Bypass Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 5 Suction Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 5 Discharge Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 5 Suction Bypass Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 6 Suction Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 6 Discharge Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 6 Suction Bypass Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 7 Suction Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 7 Discharge Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 7 Suction Bypass Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 8 Suction Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 8 Discharge Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 8 Suction Bypass Valve
0
0
0
0
0
0
0
0.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
0
0
0
0
0
0
0
0.0
0.0
0
RWPS Pump 9 Suction Valve
79
0
4096
0
0
0
0
999999.0
44
0
0
0
0
0
0
0
9
15
2022
0
0
0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS Pump 9 Discharge Valve
79
0
4096
0
0
0
0
999999.0
44
0
0
0
0
0
0
0
3
20
2023
0
0
0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS To Reservoir West Suction Valve
8335
384
4096
0
0
0
0
999999.0
10331
0
0
0
0
0
0
0
5
2
2024
0
0
0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS To Reservoir West Discharge Valve
8335
384
4097
0
0
0
0
999999.0
10310
0
0
0
0
0
0
0
5
2
2024
0
0
0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS To Reservoir East Suction Valve
8335
384
4096
0
0
0
0
999999.0
10199
0
0
0
0
0
0
0
5
6
2024
0
0
0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS To Reservoir East Discharge Valve
8335
384
4097
0
0
0
0
999999.0
10194
0
0
0
0
0
0
0
5
6
2024
0
0
0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
400.0
400.0
2
0
0
0
0
0
1000
0
5.0
5.0
2
0
0
0
0
0
250
0
5.0
5.0
0
RWPS Reservoir Valve West Side
2071
512
0
0
0
0
4057
0.0
100.0
1.5
0.0
0.0
0.0
0.0
4000
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
750
0
30.0
30.0
999999.0
0.35625
0.35625
0
RWPS Reservoir Valve East Side
6167
512
0
3
0
0
4050
-10.0
0.0
1.5
0.0
0.0
0.0
0.0
4000
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
1
0
30.0
30.0
2
0
0
0
0
0
750
0
30.0
30.0
2
0
0
0
0
0
250
0
5.0
5.0
2
0
0
0
0
0
750
0
30.0
30.0
999999.0
0.3125
0.3125
0
RWPS Pump 1 Discharge Valve Closed Status
RWPS Pump 2 Scada Enabled
RWPS Pump 2 Run Status
RWPS Pump 2 Suction Valve Remote Enabled
RWPS Pump 2 Suction Valve Local Enabled
RWPS Pump 2 Suction Valve Open Status
RWPS Pump 2 Suction Valve Closed Status
RWPS Pump 2 Control Valve Open Status
RWPS Pump 2 Control Valve Closed Status
RWPS Pump 2 Discharge Valve Remote Enabled
RWPS Pump 2 Discharge Valve Local Enabled
RWPS Pump 2 Discharge Valve Open Status
RWPS Pump 2 Discharge Valve Closed Status
RWPS Pump 9 Scada Enabled
RWPS Pump 9 Run Status
RWPS Pump 9 Suction Valve Remote Enabled
RWPS Pump 9 Suction Valve Local Enabled
RWPS Pump 9 Suction Valve Open Status
RWPS Pump 9 Suction Valve Closed Status
RWPS Pump 9 Control Valve Open Status
RWPS Pump 9 Control Valve Closed Status
RWPS Pump 9 Discharge Valve Remote Enabled
RWPS Pump 9 Discharge Valve Local Enabled
RWPS Pump 9 Discharge Valve Open Status
RWPS Pump 9 Discharge Valve Closed Status
RWPS Stand-By Generator Run Status
RWPS Stand-By Generator Common Alarm
RWPS 480V Switchgear Main "C3" Power Mode
RWPS 480V Switchgear "C3" Power Available
RWPS 480V Switchgear Main "D3" Power Mode
RWPS 480V Switchgear "D3" Power Available
RWPS 480V Switchgear Transfer Failure
RWPS 480V Switchgear Tie No.1 Open Status
RWPS 480V Switchgear Tie No.2 Open Status
RWPS Pump 2 Suction Valve Open Command
RWPS Pump 2 Suction Valve Close Command
RWPS Pump 2 Discharge Valve Open Command
RWPS Pump 2 Discharge Valve Close Command
RWPS Pump 2 Scada Start
RWPS Pump 2 Scada Stop
RWPS East Intake Valve Open Command
RWPS East Intake Valve Close Command
RWPS East Suction Valve Open Command
RWPS East Suction Valve Close Command
RWPS Northwest Sump Pump Auto Enabled
RWPS Northwest Sump Pump Run Status
RWPS Southwest By Pump 1 Sump Pump Auto Enabled
RWPS Southwest By Pump 1 Sump Pump Run Status
RWPS Southwest By Pump 4 Sump Pump Auto Enabled
RWPS Southwest By Pump 4 Sump Pump Run Status
RWPS West Alcove Sump Pump Auto Enabled
RWPS West Alcove Sump Pump Run Status
RWPS Northeast Sump Pump Run Status
RWPS Southeast Sump Pump Auto Enabled
RWPS Southeast Sump Pump Run Status
RWPS East Alcove Sump Pump Auto Enabled
RWPS East Alcove Sump Pump Run Status
RWPS West Elevator Sump Pump Auto Enabled
RWPS West Elevator Sump Pump Run Status
RWPS East Elevator Sump Pump Auto Enabled
RWPS East Elevator Sump Pump Run Status
RWPS West Secondary Dewatering Pump A Auto Enabled
RWPS West Secondary Dewatering Pump A Run Status
RWPS West Secondary Dewatering Pump A Stop Status
RWPS West Secondary Dewatering Pump B Auto Enabled
RWPS West Secondary Dewatering Pump B Run Status
RWPS West Secondary Dewatering Pump B Stop Status
RWPS East Secondary Dewatering Pump C Auto Enabled
RWPS East Secondary Dewatering Pump C Run Status
RWPS East Secondary Dewatering Pump C Stop Status
RWPS East Secondary Dewatering Pump D Auto Enabled
RWPS East Secondary Dewatering Pump D Run Status
RWPS East Secondary Dewatering Pump D Stop Status
RWPS West Dam Collector Pump A Auto Enabled
RWPS West Dam Collector Pump A Run Status
RWPS West Dam Collector Pump B Auto Enabled
RWPS West Dam Collector Pump B Run Status
RWPS East Dam Collector Pump A Auto Enabled
RWPS East Dam Collector Pump A Run Status
RWPS East Dam Collector Pump B Auto Enabled
RWPS Pump 9 Suction Valve Open Command
RWPS Pump 9 Suction Valve Close Command
RWPS Pump 9 Discharge Valve Open Command
RWPS Pump 9 Discharge Valve Close Command
RWPS Pump 9 Scada Start
RWPS Pump 9 Scada Stop
RWPS To Reservoir East Suction Valve Open Command
RWPS To Reservoir East Suction Valve Close Command
RWPS To Reservoir East Sleeve Valve Open Command
RWPS To Reservoir East Sleeve Valve Close Command
RWPS To Reservoir East Discharge Valve Open Command
RWPS To Reservoir East Discharge Valve Close Command
RWPS Main "B1" Closed Status
RWPS Tie Breaker 1 Closed Status
RWPS Main "B2" Closed Status
RWPS Tie Breaker 2 Closed Status
RWPS Recloser 3 Open Status
RWPS Recloser 3 Close Status
RWPS Recloser 4 Open Status
RWPS Recloser 4 Close Status
RWPS To Reservoir West Suction Valve Open Command
RWPS To Reservoir West Suction Valve Close Command
RWPS To Reservoir West Sleeve Valve Open Command
RWPS To Reservoir West Sleeve Valve Close Command
RWPS To Reservoir West Discharge Valve Open Command
RWPS To Reservoir West Discharge Valve Close Command
RWPS Pump 3 PCV Trip Delay
RWPS Pump 4 PCV Trip Delay
RWPS Pump 5 PCV Trip Delay
RWPS Pump 6 PCV Trip Delay
RWPS Pump 7 PCV Trip Delay
RWPS Pump 8 PCV Trip Delay
Pump 1 Watchdog Timer Value to VFD
Pump 2 Watchdog Timer Value to VFD
Pump 9 Watchdog Timer Value to VFD
RWPS PLC 001-1 Rack 0 Slot 2 Fault
RWPS PLC 001-1 Rack 0 Slot 4 Fault
RWPS PLC 001-1 Rack 0 Slot 5 Fault
RWPS PLC 001-1 Rack 0 Slot 6 Fault
RWPS PLC 001-1 Rack 0 Slot 7 Fault
RWPS PLC 001-1 Rack 0 Slot 8 Fault
RWPS PLC 001-1 Rack 0 Slot 9 Fault
RWPS PLC 001-1 Rack 0 Slot 10 Fault
RWPS PLC 001-1 Rack 0 Slot 11 Fault
RWPS PLC 001-1 Rack 1 Slot 0 Fault
RWPS PLC 001-1 Rack 1 Slot 1 Fault
RWPS PLC 001-1 Rack 1 Slot 2 Fault
RWPS PLC 001-1 Rack 1 Slot 3 Fault
RWPS PLC 001-1 Rack 1 Slot 4 Fault
RWPS PLC 001-1 Rack 1 Slot 5 Fault
RWPS PLC 001-1 Rack 1 Slot 6 Fault
RWPS PLC 001-1 Rack 1 Slot 7 Fault
RWPS PLC 001-1 Rack 1 Slot 8 Fault
RWPS PLC 001-1 Rack 1 Slot 9 Fault
RWPS PLC 001-1 Rack 1 Slot 10 Fault
RWPS PLC 001-1 Rack 1 Slot 11 Fault
RWPS PLC 001-1 Rack 2 Slot 0 Fault
RWPS PLC 001-1 Rack 2 Slot 7 Fault
RWPS PLC 001-1 Rack 3 Slot 7 Fault
RWPS PLC 001-1 Rack 4 Slot 0 Fault
RWPS PLC 001-1 Rack 4 Slot 1 Fault
RWPS PLC 001-1 Rack 4 Slot 2 Fault
RWPS PLC 001-1 Rack 4 Slot 3 Fault
RWPS PLC 001-1 Rack 4 Slot 4 Fault
RWPS PLC 001-1 Rack 4 Slot 5 Fault
RWPS PLC 001-1 Rack 4 Slot 6 Fault
RWPS PLC 001-1 Rack 4 Slot 7 Fault
RWPS PLC 001-1 Rack 4 Slot 8 Fault
RWPS PLC 001-1 Rack 5 Slot 0 Fault
RWPS PLC 001-1 Rack 5 Slot 1 Fault
RWPS PLC 001-1 Rack 5 Slot 2 Fault
RWPS PLC 001-1 Rack 5 Slot 3 Fault
RWPS PLC 001-1 Rack 5 Slot 5 Fault
RWPS PLC 001-1 Rack 5 Slot 6 Fault
RWPS PLC 001-1 Rack 5 Slot 7 Fault
RWPS PLC 001-1 Rack 5 Slot 8 Fault
RWPS PLC 001-1 Rack 6 Slot 0 Fault
RWPS PLC 001-1 Rack 6 Slot 1 Fault
RWPS PLC 001-1 Rack 6 Slot 2 Fault
RWPS PLC 001-1 Rack 6 Slot 3 Fault
RWPS PLC 001-1 Rack 6 Slot 4 Fault
RWPS PLC 001-1 Rack 6 Slot 5 Fault
RWPS PLC 001-1 Rack 6 Slot 6 Fault
RWPS PLC 001-1 Rack 6 Slot 7 Fault
RWPS PLC 001-1 Rack 6 Slot 8 Fault
RWPS PLC 001-1 Rack 2 Slot 1 Fault
RWPS PLC 001-1 Rack 2 Slot 2 Fault
RWPS PLC 001-1 Rack 2 Slot 3 Fault
RWPS PLC 001-1 Rack 2 Slot 4 Fault
RWPS PLC 001-1 Rack 2 Slot 5 Fault
RWPS PLC 001-1 Rack 2 Slot 6 Fault
RWPS PLC 001-1 Rack 2 Slot 8 Fault
RWPS PLC 001-1 Rack 2 Slot 9 Fault
RWPS PLC 001-1 Rack 2 Slot 10 Fault
RWPS PLC 001-1 Rack 2 Slot 11 Fault
RWPS PLC 001-1 Rack 3 Slot 0 Fault
RWPS PLC 001-1 Rack 3 Slot 1 Fault
RWPS PLC 001-1 Rack 3 Slot 2 Fault
RWPS PLC 001-1 Rack 3 Slot 3 Fault
RWPS PLC 001-1 Rack 3 Slot 4 Fault
RWPS PLC 001-1 Rack 3 Slot 5 Fault
RWPS PLC 001-1 Rack 3 Slot 6 Fault
RWPS PLC 001-1 Rack 3 Slot 8 Fault
RWPS PLC 001-1 Rack 3 Slot 9 Fault
RWPS PLC 001-1 Rack 3 Slot 10 Fault
RWPS PLC 001-1 Rack 3 Slot 11 Fault
RWPS Next Pump Stop Required
RWPS Next Pump Start Required
RWPS Reservoir Release Flow PID In Auto
RWPS Reservoir Lead-Lag Valve Order. (1 = Lead; 0 =Lag)
RWPS PLC Global Reset
RWPS Discharge Maintenance Dewatering Pump Run
RWPS East Dam Collector Pump B Run Status
RWPS Northeast Sump Pump Auto Enabled
RWPS West Intake Valve Command Interlock Alarm
RWPS West Suction Valve Command Interlock Alarm
RWPS East Intake Valve Command Interlock Alarm
RWPS West Intake Valve Command Interlock
RWPS Scada UPS Panel UPS Bypass Status
RWPS Security UPS Panel UPS Bypass Status
RWPS Intake Maintenance Dewatering Pump Run
RWPS TSR Inlet Flow PID HMI Auto Command
RWPS TSR Demand Enable
RWPS TSR High And Low Level Alarms Disable
RWPS High Level Float Switch Bypass
RWPS Pumps Avail Permissive HMI Override
RWPS AFD At Least 1 Pump In Auto And 1 Pump Is Ready in Local
RWPS No Pump is Available for Next Start
RWPS Pump Alternation Active
RWPS Pump Alternation Failure
RWPS Pump Alternation Failure Reset
RWPS Pump 1 Scada Unplanned Stop
RWPS Pump 3 Scada Unplanned Stop
RWPS Pump 4 Scada Unplanned Stop
RWPS Pump 5 Scada Unplanned stop
RWPS Pump 2 Scada Unplanned Stop
RWPS Pump 6 Scada Unplanned Stop
RWPS Pump 7 Scada Unplanned stop
RWPS Pump 8 Scada Unplanned Stop
RWPS Pump 9 Scada Unplanned Stop
RWPS TSR Inlet Flow PID Auto Status (1 = Auto, 0= Man)
At Least One Pump Is Running Peer to WA3253-PLC-001-1
WA3253-PLC-001-1 Watchdog Timer
RWPS Flow To Reservoir Flow Total Selection (0 - PULSE / 1 - Timer Event)
RWPS Flow To Reservoir Total Reset from SCADA
RWPS HMI Auto/Manual Command ( 0 = Devices To Manual 1 Devices To Auto)
RWPS HMI Valves 2A And 2B Auto/Manual Command ( 0 = Devices To Manual 1 Devices To Auto)
RWPS Next Start Permission ( Pump run < 2)
RWPS PLC Time - Day
RWPS PLC Time - Hour
RWPS PLC Time - Min
RWPS PLC Time - Month
RWPS PLC Time - Second
RWPS PLC Time - Year
RWPS Next Pump Start Delay
RWPS Next Pump Stop Delay
RWPS Reservoir Release Flow Setpoint
RWPS Reservoir Release Flow PID Output
RWPS TSR Inlet Flow PID Output
RWPS TSR Demand Flow Setpoint
RWPS TSR High Level Band Setpoint
RWPS TSR Low Level Band Setpoint
RWPS To Reservoir Valve Swap Timer (Days)
RWPS Pumps Alternate Timer Setpoint
Flow to TSR From Meter Vault FIT
RWPS TSR Midband Level Setpoint
RWPS Flow To Reservoir Flow Total Today
RWPS Flow To Reservoir Flow Total Yesterday
RWPS Flow To Reservoir Total Since Last Reset
RWPS TSR Low Level Band Setpoint 100 % Speeds Timer in Min
Medium Voltage Generator 1 Run Status
Medium Voltage Generator 2 Running Status
RWPS GEN-0130-2 Main Breaker (In SWG-0130-1; from Generator) Closed Status
RWPS GEN-0130-2 Main Breaker (In SWG-0130-1; from Generator) Open Status
RWPS "GB" Feeder Breaker (In SWG-0130-1) To SWG-0112-2 Closed Status
RWPS "GB" Feeder Breaker (In SWG-0130-1) To SWG-0112-2 Open Status
RWPS "GA" Feeder Breaker (In SWG-0130-1) To SWG-0112-1 Closed Status
RWPS "GA" Feeder Breaker (In SWG-0130-1) To SWG-0112-1 Open Status
RWPS GEN-0130-1 Main Breaker (In SWG-0130-1; from Generator) Closed Status
RWPS GEN-0130-1 Main Breaker (In SWG-0130-1; from Generator) Open Status
Mains A1 and B1 open and Ties are open
Lockout for HH Pumps 3, 4, and 5
Mains A2 and B2 are open and ties are open
Lockout for High Head Pumps 6, 7, and 8
One Medium Voltage Generator is running and is NOT powering the LV switchgear
Lockout to Low Head Pumps 1 and 2
Lockout to Low Head Pump 9
PLC Clock Control with Midnight Flag.(Version 1.0 - M580)
PLC Time and Date updated to User or SCADA Server values when set "true"
Entered Month Value (1-12)
Entered Day of Month Value (1-31)
Entered Year Value (2017-2099 or 00-99)
Entered Hour Value (0-12)
Entered Minute Value (0-59)
Entered Seconds Value (1-59)
Current Day of Week from PLC Calendar
Current Month from PLC Calendar
Current Day from PLC Calendar
Current Year from PLC Calendar
Current Hour from PLC Clock
Current Minuite from PLC Clock
Current Second from PLC Clock
New Day - Set to true for 1 Second at PLC Clock Midnight.
PLC Real Time Clock Value
Seconds (16#ss,-)
Hour, Minute (16#hhmm)
Month, Day (16#mmdd)
year (16#yyyy)
Internal Time being Written to PLC Real Time Clock
This section writes to the PLC clock
SYSTEM TIME - SET PLC REAL TIME CLOCK
Update the PLC Real time Clock with conditioned values
Day and Month into Third integer of the Set DateTime Array - set_plc_rtc
If entered value is greater than 2010, subtract 2000, else limit from 0-99 & add 2000.
Year into fourth integer of the Set DateTime Array - set_plc_rtc
Move array into Day Time format and update the clock
After Block inputs are limted to appropriate range, the datatypes are converted and put into an array used by the PLC Real time Clock, when the update bit is set true, the clock is updated with the array values.
Minutes and Hours into the second integer of the Set DateTime Array - set_plc_rtc
This section reads the PLC clock
Derive Minutes and Hours from the second integer of the DateTime Array - plc_rtc
Extract the PLC Real TIme Clock into DATE TIME Format, then extract the DATE TIME into an array.
Use a Multiplexer to select proper BCD Type values for Day of Week
Derive year from the final integer of the DateTime Array - plc_rtc
Derive Seconds from the first integer of the DateTime Array - plc_rtc
SYSTEM TIME - GET PLC REAL TIME CLOCK CURRENT VALUES
- Derive Day of Week, Second, Minuite, Hour, Day, Month, and Year from PLC System Real Time Clock DT Format.
Derive Day and Month from the third integer of the DateTime Array - plc_rtc
This section determines when a new day has occured
SYSTEM TIME - CALCULATE MIDNIGHT
- At midnight generate a New Day flag for Totalizer Reset
If PLC Clock Hour =0, Minuite=0, and Second=0, flag new day.
Digital input fault routing - ladder based
Input tag to monitor for alarm
Input value signifying alarm
Device IO Fault
Global Reset from Logic
Suppress Alarm from Program Control
UnSuppress Alarm from Program Control
Unshelve Alarm from Program Control
DDT for use with dfb_Alarm
1 = In Alarm
Annunciate Alarm
Alarm has been Acknowledged
Alarm is latched but can be reset because condition is cleared.
Fault Is In Alarm (on longer than the delay)
Alarm Time Remaining: Seconds Remaining Until Alarm is Tripped
dfb_Alarm for handling alarms
Alarm is in fault
PLC IO Fault Alarm
Set all Alarm DFB's Shelve Duration Time. The HMI is using "DI_L.Alarm" for the initial Shelve Duration.
if any one of the Alarms are on, set the general GenAlarm bit
Map items from DDT
if any one of the Annunciate bits are on, set the general GenAnnunciate bit.
Input value signifying alarm
DI ALARM
If the input is on, activate the alarm if it is enabled
Map items to DDT
Input tag to monitor for alarm
Acknowledge Command from Logic to Acknowledge All Alarms in this DFB
if in alarm and all alarms in the alarm array are either not in alarm or resetable, then the overall device is resetable.
When the Shelve Timer is Done Un-Latch the Shelve Command from HMI.
0= enable alarm
dfb_DI_L
Ladder based discrete alarm handling with messages.
Deterimine if input is in fault.
Discrete input condition indicating a faulted state
if any one of the aknowledged bits are on, set the GenAlarmAcked bit
Move Alarm Notify # to 0 if no Alarms are active.
DDT for DI Ladder DFB: Digital input fault routing - ladder based, No Strings
First integer of packed bits
Input tag to monitor for alarm
Input is in fault
Input value signifying alarm
Fault Is In Alarm (on longer than the delay)
0 = enable alarm
Reset Alarm
Acknowledge Alarm
Maintenance Command to Enable Alarm
Maintenance Command to Disable Alarm
At Least One Alarm is Active
At Least One Alarm is Annunciating
At Least One Alarm is Acknowledged
At least one alarm is latched and all latched alarms are resetable
Shelve Command from HMI
Suppress Command from HMI
Second integer of packed bits
Reset all Alarms On this PLC
Suppress Alarm from Program Control
UnSuppress Alarm from Program Control
Unshelve Alarm from Program Control
Alarm is in fault
Shelved Status
Suppressed Status
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
Tagged Out of Service
Spare Third integer of packed bits.
Spare Fourth integer of packed bits.
Spare Integer
Spare Integer
ddt_Alarm for handling alarms
PLC Fault Alarm DDT
Alarm Time Remaining
Combined Alarm Value Notification for HMI
DDT for Alarm DFB, No Strings
First Integer of packed Bits
Discrete input condition indicating a faulted state.
Value of the Fault input that indicates an alarm condition
Used to reset all alarms in the PLC
Fault Is In Alarm (on longer than the delay)
Alarm: Output indicating a fault has progressed to alarm state.
Annunciate, indicator to flash alarm on HMI. Set once a fault has reached alarm status. Setting Ack will reset Annuciate and will only set again once the fault transitions from False to True again.
Acknowledged: Alarm has been acknowledged, will stop the individual alarms from blinking on the popups
Alarm is latched but can be reset becasue condition is cleared.
Reset this alarm only
Acknowledge Command
Remove the Acknowledge Status
Maintenance Command to Enable Alarm
Maintenance Command to Disable Alarm
Operator Command to Shelve Alarm
Operator Command to UnShelve Alarm
Supervisor Command to Suppress Alarm
Second Integer of packed Bits
Supervisor Command to Unsuppress Alarm
Alarm and Events Shelve Timer Done
Discrete Input condition indicating a Bad Signal condition
Alarm and Events Bools
Suppress Alarm Command to AE Server
UnSuppress Alarm Command to AE Server
Shelve Alarm Command to AE Server
Unshelve Alarm Command to AE Server
Enable Alarm Command to AE Server
Disable Alarm Command to AE Server
Acknowlege Command to AE Server
Reset Command to AE Server
Alarm Suppressed Status from AE Server
Alarm Shelved Status from AE Server
Alarm Disabled Status from AE Server
Alarm Acknowledged Status from AE Server
Alarm Command to AE Server
Spare Int
Spare Int
Alarm Value Notification for Alarm and Event Server
Alarm and Events Severity (0-1000)
Alarm and Events Suppress Duration Setpoint
Alarm Delay: Seconds before a fault will progress to alarm state.
Alarm Time Remaining: Seconds Remaining Until Alarm is Tripped
This DFB supports alarming on a discrete value (Fault). The alarm can be tripped by Fault being 0 or 1 (as defined by the AlarmState input).
Discrete input condition indicating a faulted state.
Value of the Fault input that indicates an alarm condition
Discrete input condition indicating a Bad Signal condition
Global Reset from Logic
Suppress Alarm from Program Control
UnSuppress Alarm from Program Control
Unshelve Alarm from Program Control
Alarm DDT
Alarm: Output indicating a fault has progressed to alarm state.
Annunciate, indicator to flash alarm on HMI. Set once a fault has reached alarm status. Setting Ack will reset Annuciate and will only set again once the fault transitions from False to True again.
Acknowledged: Alarm has been acknowledged, will stop the individual alarms from blinking on the popups
Alarm is latched but can bee reset becasue condition is cleared.
Fault Is In Alarm (on longer than the delay)
1=Alarm has been suppressed, shelved or disabled, display "S" icon
Alarm Time Remaining: Seconds Remaining Until Alarm is Tripped
Alarm Suppressed Status
Alarm Disabled Status
Alarm Shelved Status
True for one scan following the alarm tripping.
Working Internal Alarm Suppressed Status
Number of Minutes until this alarm unshelves itself
Used to reset all alarms in the PLC
Reset: HMI input used to reset an alarm once the fault has been cleared.
Discret input indicating a faulted state
Value of the fault input indicates an alarm condition
Discret input indicating a faulted state
Value of the fault input indicates an alarm condition
Value of the fault input indicates an alarm condition
Value of the fault input indicates an alarm condition
Fault is in Alarm - on longer than the delay
Latch Acked if acknowledged or reset by the HMI while the alarm is active. Break the latch if the alarm trips again (if may have cleared while latched and tripped again). Break the latch if another alarm outside this DFB
This rung receives the program command for suppress
This rung receives the Operator Unshelve Command (Unshelve wins over Shelve)
and the Program Unshelve Command
Also Unshelve the alarm if the Shelf Timer expires (if preset > 0).
NOTE: Shelved can also be set/cleared directly by the HMI (FTA&E support).
Send Alarm Status to AE Server
This rung receives the Maintenance Alarm Enable Command (Enable wins over Disable)
NOTE: Disabled can also be set/cleared directly by the HMI (FTA&E support).
Set delay time (miliSeconds) based on alarm delay in seconds. Then convert to type TIME.
Send Alarm Acknowldege to AE Server
Notify Level (color, blink) is determined here.
0 = No Alarm
8 = Alert severity, resettable, unacknowledged
9 = Alert severity, resettable
10 = Alert severity, acknowledged
11 = Alert severity, unacknowledged
12 = Alert severity, Bad, resettable, unacknowledged
13 = Alert severity, Bad, resettable
14 = Alert severity, Bad, acknowledged
15 = Alert severity, Bad, unacknowledged
16 = Low severity alarm, resettable, unacknowledged
17 = Low severity alarm, resettable
18 = Low severity alarm, acknowledged
19 = Low severity alarm, unacknowledged
20 = Low severity, Bad, resettable, unacknowledged
21 = Low severity, Bad, resettable
22 = Low severity, Bad, acknowledged
23 = Low severity, Bad, unacknowledged
32 = Medium severity alarm, resettable, unacknowledged
33 = Medium severity alarm, resettable
34 = Medium severity alarm, acknowledged
35 = Medium severity alarm, unacknowledged
36 = Medium severity, Bad, resettable, unacknowledged
37 = Medium severity, Bad, resettable
38 = Medium severity, Bad, acknowledged
39 = Medium severity, Bad, unacknowledged
48 = High severity alarm, resettable, unacknowledged
49 = High severity alarm, resettable
50 = High severity alarm, acknowledged
51 = High severity alarm, unacknowledged
52 = High severity, Bad, resettable, unacknowledged
53 = High severity, Bad, resettable
54 = High severity, Bad, acknowledged
55 = High severity, Bad, unacknowledged
64 = Urgent severity alarm, resettable, unacknowledged
65 = Urgent severity alarm, resettable
66 = Urgent severity alarm, acknowledged
67 = Urgent severity alarm, unacknowledged
68 = Urgent severity, Bad, resettable, unacknowledged
69 = Urgent severity, Bad, resettable
70 = Urgent severity, Bad, acknowledged
71 = Urgent severity, Bad, unacknowledged
Send Alarm Acknowldege to AE Server
Send Alarm Acknowldege to AE Server
This rung times how long the alarm has been shelved.
If the Shelf Timer expires (and its preset > 0), automatically unshelve the alarm.
If the command is received while shelved, the shelf timer starts over (reset).
Start delay timer when fault is the same as the alarm state.
Suppress is cleared if the program command for suppress is cleared
This rung receives the Maintenance Alarm Disable Command
These synchronize the Alarm and Event Statuses with the alarm
============================================================
COMMAND PROCESSING
============================================================
These rungs handle received Commands:
Operator Commands (Operxx) and Maintenance Commands
(MCmd_xx) from the HMI and
Program Command (PCmd_xx) from other objects.
NOTE: ALARM COMMANDS ARE ACCEPTED REGARDLESS OF MODE.
This rung receives the Program Alarm Inhibit Command.
Send Alarm Acknowldege to AE Server
Alarm Severity: 1=Alert, 2..250=Low, 251..500=Medium, 501..750=High, 751..1000=Urgent
This rung calculates the number of seconds until this alarm "unshelves" itself.
If the alarm is already unshelved, clear this number.
Latch the unacknowledged status if the alarm goes away without being acknowledged or reset or re-occuring.
============================================================
VALUE / STATUS GENERATION
============================================================
This rung copies the internal working status (Suppressed, In Alarm)
to public Status bits. Note that internal working bits are used so that
outside objects cannot manipulate the state of this object
by setting/clearing its Status and Alarm bits.
Public Status is generated for:
Alarm (with minimum ON time to be seen by polling)
Alarm Suppressed
Unsuppressed, Unshelved and Enabled are generated for HMI.
(Ack, Shelved and Disabled can be set/cleared by the HMI directly.
Note that these bits are "read/write" outputs in the parameter definition.)
Clear HMI Commands after a short periof of time. The timers were used to allow multiple alarms to be used in a single DFB such as the Ain DFB, and not have the first ACK and RESET turn off before the others see it.
Map items from DDT
Map items to DDT
Latch the annunciate bit when the alarm ccurs. Unlatch when either Acked or the fault clears.
Latch Alarm when the alarm trips. Hold it latched until reset while fault timer is not done.
If there is a PLC wide global reset, latch the local alarm reset so the global reset has the same effect as the local reset.
This rung receives the Operator Shelve Command.
If the command is received while shelved, the shelf timer starts over (reset).
Analog Inputs
Raw from Input Card
Reset all Alarms On this DFB
Used for Scaling to EU
Used for Scaling to EU
This prescan routine is only exicuted before the first scan or on changes from program mode to run mode:
Suppress Level Alarms (LL, L, H, HH, & ROC)
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
System Time
Analog Input DDT
Suppress Alarm from Program Control
UnSuppress Alarm from Program Control
Unshelve Alarm from Program Control
At Least One Alarm is Active
At Least One Alarm is Annuciating
At Least One Alarm is Acknowledged
At least one alarm is latched and all latched alarms are resetable
Scaled Value in Engineering Units
Locked by Program
Device has a Broken Loop Alarm
Device Signal is Under Range Alarm
Device Signal is Low Low Alarm
Device Signal is Low Alarm
Device Signal is High Alarm
Device Signal is High High Alarm
Device Signal is Over Range Alarm
Device Rate of Change Alarm
Totalizing DFB
PLC IO Fault
totalized value since totalizer was last reset.
Ain.RawMax: Raw Value used for scaling to EU
Ain.INTK_Reset_SP: Interlock Reset Setpoint
High Alarm.
Rate of Change Alarm.
Test for a Under Range fault.
Trip the immediate fault if enabled and raw is less than the set point.
Reset the alarm in either the AOI reset or the Global Reset are set.
Process the Alarm with the Alarm AOI
Set the Alarm bit.
Call the Alarm AOI for the IO PLC Fault
Test for a Rate of Change fault.
Trip the imidiate fault if enabled and absolute value of the change (* 5 to get change per second based on 200 ms period) is greater than the set point.
Write current EU to old value for next scan.
Reset the alarm in either the AOI reset or the Global Reset are set.
Process the Alarm with the Alarm AOI
Set the Alarm bit.
ABS(Old_Val-VALU)*5 > RCSP
PCSuppress:
Ain.RawMin: Used for Scaling to EU
if any one of the Annunciate bits are on, set the general GenAnnuciate bit
Ain.GlobalReset: Reset all Alarms in this DFB
Ain.INTK_Reset_SP: Interlock Reset Setpoint
Test for a High fault.
Trip the immediate fault if enabled and raw is greater than the set point.
Reset the alarm in either the AOI reset or the Global Reset are set.
Process the Alarm with the Alarm AOI
Set the Alarm bit.
PCUnSuppress:
Map items from DDT
Ain.LL_SP: Low Low Alarm Limit
Test for a Broken loop fault.
Trip the immediate fault if enabled and raw is less than the set point.
Reset the alarm in either the AOI reset or the Global Reset are set.
Process the Alarm with the Alarm AOI
Set the Alarm bit.
Under Range Alarm.
Ain.SuppressLA: Suppress Level Alarms (LL, L, H, HH, ROC)
Set true to totalize flow.
Ain.BLSP: Raw Low Limit for Broken Loop
RawMax: Used for Scaling to EU
GlobalReset: Reset all Alarms in this DFB
Ain.PCUnShelve:
Test for a Low fault.
Trip the immediate fault if enabled and raw is less than the set point.
Reset the alarm in either the AOI reset or the Global Reset are set.
Process the Alarm with the Alarm AOI
Set the Alarm bit.
High High Alarm.
if any one of the acknowledged bits are on, set the GenAlarmAcked bit
Test for a High High fault.
Trip the immediate fault if enabled and raw is greater than the set point.
Reset the alarm in either the AOI reset or the Global Reset are set.
Process the Alarm with the Alarm AOI
Set the Alarm bit.
PCUnShelve:
Ain.Raw: Raw Value from input card
Ain.ORSP: Over Range Raw Alarm Limit
Interlock: If the Interlock is Enabled, check to see if the VALU(Engineering Unit) is Greater than the Interlock Setpoint.
Ain.INTK_SP: Interlock Setpoint
Ain.VMIN: Scaled Value with Raw at RawMin
Set all Alarm DFB's Shelve Duration Time. The HMI is using "almHighHigh" for the initial Shelve Duration.
Ain.Raw: Raw Value from input card
If above the Interlock Setpoint you are now interlocked. The Interlock will automatically clear when the VALU is below the Interlock reset setpoint.
If there is a PLC wide global reset, latch the local alarm reset so the global reset has the same effect as the local reset.
Ain.RCSP: Max Absolute Chnage in EU per second to trip the Rate of Change Fault
Ain.RawMin: Raw Value used for scaling to EU
Ain.PCSuppress:
Ain.LL_SP: Low Low Alarm Limit
Ain.URSP: Under Range Raw Alarm Limit
Test for a Over Range fault.
Trip the immediate fault if enabled and raw is greater than the set point.
Reset the alarm in either the AOI reset or the Global Reset are set.
Process the Alarm with the Alarm AOI
Set the Alarm bit.
To avoid division by zero, the RawMin and RawMax must be different.
Ain.Raw: Raw Value from input card
totalized value since totalizer was last reset.
Test for a Low Low fault.
Trip the immediate fault if enabled and raw is less than the set point.
Reset the alarm in either the AOI reset or the Global Reset are set.
Process the Alarm with the Alarm AOI
Set the Alarm bit.
Ain.RawMax: Used for Scaling to EU
Ain.Raw: Raw Value from input card
Map items to DDT
RawMin: Used for Scaling to EU
if in alarm and all alarms in the alarm array are either not in alarm or resetable, then the overall device is resetable.
Raw: Raw from Input Card
if any one of the Alarms are on, set the general GenAlarm bit
SuppressLA: Suppress Level Alarms (LL, L, H, HH, ROC)
Low Low Alarm.
Scale the raw input into engineering units.
((VMAX - VMIN) * (Raw - RawMin)/(RawMax - RawMin)) + VMIN
Ain.INTK_SP: Interlock Setpoint
Ain.H_SP: High Alarm Limit
Ain.Raw: Raw Value from input card
Clear all HMI Commands
Ain.VALU: Scaled Value in Engineering Units
Ain.Raw: Raw Value from input card
Ain.RawMin: Raw Value used for scaling to EU
Move Alarm Notify # to 0 if no Alarms are active.
Low Alarm.
Ain.Raw: Raw from Input Card
Ain.HH_SP: High High Alarm Limit
When the Shelve Timer is Done Un-Latch the Shelve Command from HMI.
On First Scan reset all Alarms
Acknowledge Command from Logic to Acknowledge All Alarms in this DFB
This is to ensure that the reset setpoint doesn't get set above the interlock setpoint.
Ain.INTK_SP: Interlock Setpoint
Ain.INTK_Reset_SP: Interlock Reset Setpoint
Ain.Raw: Raw Value from input card
PLCFault:
Determine which Alarm has the Highest Priority when any alarm is active.
This is to determine which icon to display on HMI.
Ain.PCUnSuppress:
Broken Loop Alarm.
Over Range Alarm.
Ain.Raw: Raw Value from input card
Reset all Alarms in this AOI
Ain.PLCFault:
DDT for Analog DFB: Analog Inputs, No Strings
First Integer of packed Bits
Reset all Alarms On this PLC
Enable High High Alarm
Enable High Alarm
Enable Low Alarm
Enable Low Low Alarm
Enable Broken Loop Alarm
Enable Over Range Alarm
Enable Under Range Alarm
Enable Rate of Change Alarm
Suppress All Alarms
Suppress Level Alarms (LL, L, H, HH, & ROC)
RawMin = RawMax: Causes division by zero
High High Alarm
High Alarm
Low Alarm
Low Low Alarm
Second Integer of packed Bits
Broken Loop Alarm
Over Range Alarm
Under Range Alarm
Rate of Change Alarm
Reset all Alarms in this DFB
At Least One Alarm is Active
At Least One Alarm is Annunciating
At Least One Alarm is Acknowledged
At least one alarm is latched and all latched alarms are resetable
High High Fault
High Fault
Low Fault
Low Low Fault
Broken Loop Fault
Over Range Fault
Under Range Fault
Third Integer of packed Bits
Rate of Change Fault
Set true to totalize flow.
Tagged Out of Service
Acknowledge Command from Logic to Acknowledge All Alarms in this DFB
Locked by program (ESD)
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
Enable Interlock Alarm
Shelve Command from HMI
Shelved Status
Suppress Command from HMI
Suppressed Status
Suppress Alarm from Program Control
UnSuppress Alarm from Program Control
Unshelve Alarm from Program Control
Fourth Integer of packed Bits (SPARE)
Spare Integer
Spare Integer
Raw from Input Card
Scaled Value in Engineering Units
Prevoius Value for Rate of Change Checking
Scaled Value with Raw at RawMin
Scaled Value with Raw at RawMax
Used for Scaling to EU
Used for Scaling to EU
High High Alarm Limit
High Alarm Limit
Low Alarm Limit
Low Low Alarm Limit
Raw Low Limit for Broken Loop
Over Range Raw Alarm Limit
Under Range Raw Alarm Limit
Max Absolute Change In EU per Second to trip the Rate Of Change Fault
Interlock Alarm Limit
totalized value since totalizer was last reset.
High High Alarm DDT
First Integer of packed Bits
Second Integer of packed Bits
High Alarm DDT
Low Alarm DDT
Low Low Alarm DDT
Broken Loop Alarm DDT
Over Range Alarm DDT
Under Range Alarm DDT
Rate Of Change Alarm DDT
PLC IO Fault Alarm DDT
Totalizer DDT
Interlock Reset Setpoint
Combined Alarm Value Notification for HMI
DDT for Tot Ladder DFB: Totalizes analog value, provides increased precision compared to built in totalizer, No Strings
First Integer of Packed Bits.
This prescan routine is only exicuted before the first scan or on changes from program mode to run mode:
Start Totalizing becasue flow is above the minimum
HMI Command to Reset Flow Totals
Second Integer of Packed Bits. (SPARE)
Third Integer of Packed Bits. (SPARE)
Fourth Integer of Packed Bits. (SPARE)
Spare Integer
Spare Integer
Time base of flow: 0 = per Second, 1 = per Minute, 2 = per Hour, 3 = per Day
Scaled Analog Value
Max Scaled Analog Value
Low Flow Cut Off Percent of Max Flow That Stops Totaling
Today's Total Flow
Yesterday's Total Flow
Total FLow Since Last Reset
Counts 500 days
Keep total for past 500 days
In flow units
Time the total was last reset
Year
Month
Day
Hours
Minutes
Seconds
How often per unit of time is analog value sampled
Total Flow for the Current Minute
Total Flow for One 5th of One Second
Total Flow of all Completed Minutes Today
Totalized Value
Totalizes analog value, provides increased precision compared to built in totalizer
Scaled Analog Value
Max Scaled Analog Value
This prescan routine is only exicuted before the first scan or on changes from program mode to run mode:
System Time
Counts 500 days
Totalizer DDT
Today's Total Flow
Yesterday's Total Flow
Total FLow Since Last Reset
Counts 500 Days
Counts 500 Days Reset
Keep total for past 500 days
On First Scan reset all Alarms
Oneshot resets values on day change
Move 0 into Total Flow of all Completed Minutes Today
Total Flow for the Current Minute
Yesterday's Total Flow
Total Flow for one 5th of One Second
Year
Two Minute Count
Yesterday's Total Flow
500 Day Count
Keep total for past 500 days
Total Flow of all Completed Minutes Today
Convert current flow rate to total flow for the last 200 ms.
Total the flow for two minutes. Don't total for too long or the rounding error becomes significant. Dont total while flow is too low.
On reset command from the HMI, Reset the base totals that calcualte all the other totals.
Low flow Cutoff in Units
Total Flow Since Last Reset
Today's Total Flow
Map items from DDT
Totalized Value
Total Flow for the Current Minute
After two minutes (600 scans, each 200ms) or if it is a day roll over:
Add the two minutes total to the todays total.
Clear the two minute total and reset the scan count.
Move 0 into Total Flow for the Current Minute
Hour
Minute
How often per unit of time is analog value sampled
Move 0 into 500 Day Total Count
Calculate the overall total (the total of the 500 day total plus the current Total)
Start Totalizing because flow is above the minimum
500 Count Days reset
Month
Minute
Start Totalizing because flow is above the minimum
Move 0 into Two Minute Count
HMI Command to Reset Flow Totals
Calculate the 500 day total (the total of the competed days plus plus the current day)
HMI Command to Reset Flow Totals
Total Flow of all Completed Minutes Today
If rolling the day:
Move todays total to yesterdays.
Add todays total to the TotalTotal.
Clear todays total.
Count the number of daily rolls.
Time base of flow
0 = per Second
1 = per Minute
2 = per Hour
3 = per Day
Day
Low Flow Cutoff Percent of Max Flow That Stops Totalling
Map items to DDT
Determine what value to divide summation by to get correct units based on the time base of the flow units.
Totalized Value
Calculate the current days total (the total for today of all completed minutes plus the current minute)
Determine if a Day Roll Over will take place this scan
Hour
For modulating valves with analog position command.
1 = remote/local input wired
Remote: 1 = Device In Remote 0 = Device In Local
1 = Open adn Close Feedback is Present
Valve Position Feedback 4,000-20,000 (4,000 when closed for fail closed or open for fail open)
Used to reset all alarms in the PLC
Set to 1 if there is an auto routine. Used to hid or show Auto display on HMI
Fail Closed: 1 for Fail Closed Valves, 0 for Fail Open Valves
Set to 1 if manual control should only be done through a PID Block (never the faceplate for this valve)
Locked by program (ESD)
PLC First Scan
Valve Failure
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
For modulating valves with analog position command. DDT
Suppress Alarm from Program Control
UnSuppress Alarm from Program Control
Unshelve Alarm from Program Control
Valve Position Command 4,000-20,000 (4,000 when closed for fail closed or open for fail open)
At least one alarm on this device is active.
At least one alarm in Device is annunciating (flash the device symbol)
Acknowledged: At least one alarm has been acknowledged.
At least one alarm is latched and all latched alarms are resetable
Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
Position Feedback in % open
Broken Loop Alarm
Under Range Alarm
Over Range Alarm
Valve Position Failure
PLC IO Fault Alarm
Valve Failure Alarm
Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
Fail Closed: 1 for Fail Closed Valves, 0 for Fail Open Valves
VLVM.PO_SP: Position Setpoint in % open
VLVM.PO_SP: Position Setpoint in % open
HMI to Show Valve Opened Status.
VLVM.ZI: Valve Position Feedback 4,000-20,000 (4,000 when closed for fail closed or open for fail open)
VLVM.ManPO_SP: Manual Position Setpoint in % open
VLVM.PO_FB: Position Feedback in % open
Move Alarm Notify # to 0 if no Alarms are active.
Set to 1 if there is an auto routine. Used to hide or show Auto Display on HMI
ZC: Valve Position Command 4,000-20,000 (4,00 when closed for fail closed or open for fail open)
VLVM.ZI: Valve Position Feedback 4,000-20,000 (4,000 when closed for fail closed or open for fail open)
If tagged out of service or interlocked:
Move to the failed position (0% open for fail closed valves or 100% open for fail open valves)
If the position feedback indicates the valve is within the deadband of being opened or closed, then indicate that in the HMI.
VLVM.PO_FB: Position Feedback in % open
If in auto, set the setpoint based on the auto setpoint.
If in manual, set the setpoint based on the manual setpoint.
Map items to DDT
Set to 1 if there is an remote status. Used to hide or show Remote Display on HMI
VLVM.ZC: Valve Position Command 4,000-20,000 (4,00 when closed for fail closed or open for fail open)
VLVM.PO_SP: Position Setpoint in % open.
VLVM.ZC: Valve Position Command 4,000-20,000 (4,00 when closed for fail closed or open for fail open)
Find the shortest alarm time remaining:
Start by setting alarm time remaining very high.
Then for each alarm, if its fault is active and its time remaining is less than the current value of alarm time remaining, then set its time remaining as the overall alarm time remaining.
VLVM.BL_SP: Raw Low Limit for Broken Loop
VLVM.PositionError: In % Open + is Open Past Setpoint
VLVM.PositionError: In % Open + is Open Past Setpoint
VLVM.ATRM: Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
Suppress All Alarms.
Map items from DDT
Set by HMI
0 = Device in Manual
1 = Device in Auto
if any one of the Faults are on, set the GenFault bit
VLVM.PO_DB: Position Deadband in % open. Used to trip alarm for feedback vs. command position.
Broken Loop Fault.
HMI to Show Valve Close Command.
Call the Alarm AOI for the Position Fault (Open and Close Commands are based on position error greater than the deadband)
if in alarm and all alarms in the alarm array are either not in alarm or resetable, then the overall device is resetable.
If in remote and there is feedback:
Determine if the valve needs to be opening or closing based on the position error and the size of the deadband.
These outputs are used on the HMI to show needed valve movement.
Fail Closed: 1 for Fail Closed Valves, 0 for Fail Open Valves
VLVM.UR_SP: Under Range Raw Alarm Limit
Clear operator control bits
Acknowledge: HMI Input to reset the AlarmAckd bit.
VLVM.ZI: Valve Position Feedback 4,000-20,000 (4,000 when closed for fail closed or open for fail open)
VLVM.PO_FB: Position Feedback in % open
if any one of the Alarms are on, set the GenAlarm bit
Test for a Over Range fault.
Trip the immediate fault if enabled and raw is greater than the set point.
Reset the alarm in either the AOI reset or the Global Reset are set.
Process the Alarm with the Alarm AOI
Set the Alarm bit.
If there is a PLC wide global reset, latch the local alarm reset so the global reset has the same effect as the local reset.
##### V.1.4 Also latch the reset if swiched out of Remote and Remote is enabled. #####
If in local, set the manual setpoint based on the feedback to support bumpless transition to remote in manual.
HMI to Show Valve Open Command.
Used to reset all alarms in the PLC
Alarm Reset Command from HMI
Test for a Broken loop fault.
Trip the immediate fault if enabled and raw is less than the set point.
Reset the alarm in either the AOI reset or the Global Reset are set.
Process the Alarm with the Alarm AOI
Set the Alarm bit.
VLVM.OR_SP: Over Range Raw Alarm Limit
VLVM.ZI: Valve Position Feedback 4,000-20,000 (4,000 when closed for fail closed or open for fail open)
VLVM.ManPO_SP: Auto Position Setpoint in % open
If Auto is disabled, force into manual mode.
ATRM: Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
if any one of the Annunciate bits are on, set the GenAnnunciate bit
VLVM.PO_DB: Position Deadband in % open. Used to trip alarm for feedback vs. command position.
VLVM.ManPO_SP: Manual Position Setpoint in % open
VLVM.PO_SP: Position Setpoint in % open
VLVM.PO_SP: Position Setpoint in % open
Set by HMI
0 = Device in Manual
1 = Device in Auto
HMI to Show Valve Closed Status.
VLVM.ATRM: Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
VLVM.AutoPO_SP: Auto Position Setpoint in % open
VLVM.PO_FB: Position Feedback in % open
Scale the input to % open.
Fail Closed valves are 0% open at 4,000 raw input and 100% at 20,000 raw input.
Fail Open valves are 100% open at 4,000 raw input and 0% at 20,000 raw input.
VLVM.ATRM: Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
VLVM.ZC: Valve Position Command 4,000-20,000 (4,00 when closed for fail closed or open for fail open)
Alarm Reset Command from HMI
VLVM.PO_SP: Position Setpoint in % open
Broken Loop Alarm.
If there is a PLC wide global reset, latch the local alarm reset so the global reset has the same effect as the local reset.
Set by HMI
0 = Device in Manual
1 = Device in Auto
Call the Alarm AOI for the Motor Failure
Set to 1 if manual control should only be done through a PID Block (never the faceplate for this valve)
ZI: Valve Position Feedback 4,000-20,000 (4,000 when closed for fail closed or open for fail open)
if any one of the acknowledged bits are on, set the GenAlarmAcked bit
VLVM.PO_DB: Position Deadband in % open. Used to trip alarm for feedback vs. command position.
VLVM.ATRM: Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
VLVM.ATRM: Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
If in auto, move auto position setpoint to manual position setpoint to support bumpless transfer from auto to manual.
Call the Alarm AOI for the IO PLC Fault
Device is ready for auto control if it is in remote, in auto, not in alarm, and not tagged out of service.
VLVM.PO_FB: Position Feedback in % open
VLVM.ManPO_SP: Manual Position Setpoint in % open
Determine which Alarm has the Highest Priority when any alarm is active.
This is to determine which icon to display on HMI.
VLVM.ZI: Valve Position Feedback 4,000-20,000 (4,000 when closed for fail closed or open for fail open)
Scale the output from % open to raw current counts.
Fail Closed valves are 4,000 raw output for 0% open and 20,000 raw output for 100% open.
Fail Open valves are 20,000 raw output for 0% open and 4,000 raw output for 100% open.
VLVM.ATRM: Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
If Manual is disabled, force into AUTO mode.
Test for a Under Range fault.
Trip the immediate fault if enabled and raw is less than the set point.
Reset the alarm in either the AOI reset or the Global Reset are set.
Process the Alarm with the Alarm AOI
Set the Alarm bit.
VLVM.PO_FB: Position Feedback in % open
PO_FB: Position Feedback in % open
Enable Broken Loop Alarm
If Remote is disabled, force into Remote mode.
VLVM.PositionError: In % Open + is Open Past Setpoint
DDT for VLVM Ladder DFB: Variable Speed Motor, No Strings
First Integer of packed Bits
1 = remote/local input wired 0 = not wired
Set to 1 if there is an auto routine. Used to hide or show Auto display on HMI
1 = Open and Close Feedback is Present 0 = No Feedback
PLC First Scan
Remote: 1 = Device In Remote 0 = Device In Local
Valve Failure
Set to 1 if manual control should only be done through a PID Block (never the faceplate for this valve)
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
Used to reset all alarms in the PLC
Locked by program (ESD)
Fail Closed: 1 for Fail Closed Valves, 0 for Fail Open Valves
Enable Broken Loop Alarm
Enable Over Range Alarm
Position Failure Alarm Enable
Enable Under Range Alarm
Second Integer of packed Bits
Tagged Out of Service
Suppress All Alarms
At least one alarm on this device is active.
At least one alarm in Device is annunciating (flash the device symbol)
Acknowledged: At least one alarm has been acknowledged.
At least one alarm is latched and all latched alarms are resetable
HMI to Show Valve Close Command
HMI to Show Valve Open Command
HMI to Show Valve Opened Status
HMI to Show Valve Closed Status
Broken Loop Alarm
Position Failure Alarm (position error exceeded deadband for required delay)
Current Position Error Exceeds Deadband
Under Range Alarm
Over Range Alarm
One of the alarm conditions is currently set (may not be in alarm yet)
Third Integer of packed bits
Device is ready for auto control
Acknowledge: HMI input to reset the AlarmAckd bit.
Alarm Reset Command from HMI
Set by HMI 0 = Device in Manual 1 = Device in Auto
Under Range Fault
Broken Loop Fault
Over Range Fault
True indicates blue flag should be displayed.
Shelve Command from HMI
Shelved Status
Suppress Command from HMI
Suppressed Status
Valve Failure Alarm
Suppress Alarm from Program Control
UnSuppress Alarm from Program Control
Unshelve Alarm from Program Control
Fourth Integer of packed bits (SPARE)
1 = Interlock Enabled, 0 = Interlock Disabled
1 = Valve Failure Enabled, 0 = Valve Failure Disabled
Spare Integer
Spare Integer
Valve Position Feedback 4,000-20,000 (4,000 when closed for fail closed or open for fail open)
Raw Low Limit for Broken Loop
Over Range Raw Alarm Limit
Position Deadband in % open. Used to trip alarm for feedback vs. command position.
Under Range Raw Alarm Limit
Auto Position Setpoint in % Open
Manual Position Setpoint in % Open
Position Setpoint in % open.
Valve Position Command 4,000-20,000 (4,000 when closed for fail closed or open for fail open)
Broken Loop Alarm DDT
Under Range Alarm DDT
Over Range Alarm DDT
Valve Position Failure DDT
PLC IO Fault Alarm DDT
Valve Failure Alarm DDT
Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
Position Feedback in % open
In % Open + is Open Past Setpoint
Combined Alarm Value Notification for HMI
Variable Speed Motor
Remote: 1 = Device In Remote 0 = Device In Local
1 = remote/local input wired 0 = not wired
Set to 1 if there is An auto routine. Used to hide or show Auto display on HMI
1 = Manual Mode Disabled, Always in Auto 0 = Operator may run device in Auto or Manual
Device Running Status
Motor Fail Status from Motor Controller
VFD SPEED SETPOINT FROM PLC
Speed Indication Feedback from Device
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
1 = VFD using Hz (0-60 Hz) 0 = VFD using Percentages (0-100%)
Used to reset all alarms in the PLC
Locked by program (ESD)
Auto Start from Auto Logic
Auto Stop from Auto Logic
This prescan routine is only exicuted before the first scan or on changes from program mode to run mode:
System Time
Motor VFD DDT
Year
Month
Day
Hours
Minutes
Seconds
Suppress Alarm from Program Control
UnSuppress Alarm from Program Control
Unshelve Alarm from Program Control
Output to Physical Device
Device Run Command
At least one alarm on this device is active.
At least one alarm in Device is annunciating (flash the device symbol)
Acknowledged: At least one alarm has been acknowledged.
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
At least one alarm is latched and all latched alarms are resetable
Device Failed to Start
Device Failed to Stop
General Failure Alarm from Motor Drive
Deviation Alarm from Logic
Fail to Start, Fail to Stop or Motor Failure alarm is active
Restart Delay Remaining: in seconds
Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
Timer for preventing Device from being rapidly started and stopped: Preset Time
Timer for preventing Device from being rapidly started and stopped: Preset Time Real
One minute counter while Motor is Running
One minute counter while Motor is Running
Internal Stop Command
Internal Start Command
Timer for preventing Device from being rapidly started and stopped
Device Failed To Start
Device Failed To Stop
Device Motor Failed
Speed Deviation Alarm
One Shot for transition from Manual to Remote
Internal Run State: 1 = Motor should be running. 0 = Motor should be stopped.
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
Reset Runtimes if the reset button has been pressed
VFDMaxSP: VFD Maximum Setpont
Manual Start Command from HMI.
Set by HMI
0 = Device in Manual
1 = Device in Auto
Month
ManDisable:
1 = Manual Mode Disabled, Always in Auto
0 = Operator may run device in Auto or Manual
Hours
Maximum Value of Deviation before Timer begins
VFDScale: VFD Output in EU to be Scaled
Deviation Fault is active, this is not the delayed alarm.
Minimum Value of Deviation before Timer begins
Seconds
RTYesterdayMin:
Run Time Minutes Yesterday.
MTR.ATRM: Alarm Time Remaining: Seconds Until Alarm Trips if Fault is not Cleared.
Clear operator control bits
VFDMinSP: VFD Minimum Setpont
Device Running Status
Day
One Shot for New Day
Device is ready for auto control if it is in remote, in auto, not in alarm, not tagged out of service, and not interlocked.
Detect Motor failure from examining the command compared to the feedback.
Motor Fail input blocks the fail to start alarm to keep alarms focused on the primary issue (motor fault)
RTTodayMin: Run Time Minutes Today.
Shelve All Alarms.
VFDScale: VFD Output in EU to be Scaled
Seconds
Internal Run State
1 = Motor Should be running
0 = Motor should be stopped
RTTodayMin:
Run Time Minutes Today.
Scale Output to a 4,000-20,000 (4-20mA) signal.
Formula Assumes the following Values:
Raw Max is 20,000
Raw Min is 4,000
VFD is scaled as a Percentage and not as Hz
(((20000-4000)*VFDScale)/100)+4000
Output run command if the motor should "Start" running.
STTD:
Count of Starts Today
Count of Starts Today.
Total Count of Device Starts since last starts reset.
VFDSP: VFD Speed Setpoint
VFDScale: VFD Output in EU to be Scaled
Motor Run Timer
Minutes
Manual Start Command from HMI.
Internal Start Command
Set by HMI
0 = Device in Manual
1 = Device in Auto
Fail To Stop Alarm Time Remaining
VFDSP: VFD Speed Setpoint
Locked by program. (ESD)
VFDMinSP: VFD Minimum Setpont
MTR.ATRM: Alarm Time Remaining: Seconds Until Alarm Trips if Fault is not Cleared
MTR.ATRM: Alarm Time Remaining: Seconds Until Alarm Trips if Fault is not Cleared.
MN:
Device Running Status
This prescan routine is only exicuted before the first scan or on changes from program mode to run mode:
Clear operator control bits
Year
STRS: Total Count of Device Starts Since last starts reset.
Inhibit Motor restart.
Reset Runtime Command from HMI.
This timer is used to allow a 1 second delay to capture the accumulated time when the motor stops.
RTTotalHrs: Run Time Hours Total Since Last Reset.
Start, Stop, or Motor Failure
RTTodayMin: Run Time Minutes Today.
Year
Reset: Command from HMI to Reset all alarms on this device.
Remote:
1= Device in Remote
0= Device in Local
RTTotalMin: Run Time Minutes Since Last Reset.
Motor Runtime Accumulator Logic.
The timer accumulator in units of milliseconds up to 1 minute.
Un-Shelve All Alarms.
If in Auto, move Auto Device Speed into VFD Output to be Scaled
Map items to DDT
RTTodayHrs: Run Time Hours Today/Current.
MN:
Device Running Status
RTTotalMin: Run Time Minutes Since Last Reset.
RTYesterdayMin: Run Time Minutes Yesterday.
Reset Motor Run Timer Accumulation to 0.
Hours
if in alarm and all alarms in the alarm array are either not in alarm or resetable, then the overall device is resetable.
If in Manual, move Operator Setpoint into VFD Output to be Scaled
Minutes
Restart Delay Remaining: in Seconds.
RTTodayHrs:
Run Time Hours Today/Current.
if any one of the Alarms are on, set the general GenAlarm bit
VFDFB: Speed Indication Feedback from Device
Day
RTYesterdayHrs: Run Time Hours Yesterday.
MTR.RSRM: Restart Delay Remaining seconds.
Device is ready for auto control.
Display time remaining before Deviation Fault Alarm
STYD:
Count of Starts Yesterday.
Day
On start request, latch the internal run bit and hold until stop request or motor failure.
MTR.ATRM: Alarm Time Remaining: Seconds Until Alarm Trips if Fault is not Cleared.
VFDScale: VFD Output in EU to be Scaled
STTD:
Count of Starts Today
Set commmon fail and LOCKOUT a motor in the event of a failure
Reset Runtime Command from HMI.
Inhibit Timer Preset
Monitor a START request for the present state to set the INTERNAL START
PC_MAN and PC_AUTO) only work if in remote (or remote is not enabled) and the inhibit timer is done.
If remote is enabled and in local, monitor for local starts to support bumpless transfer to Remote.
RTTodayMin: Run Time Minutes Today.
If the Setpoint to be scaled is greater than the Max allowed setpoint, move max setpoint into output to be scaled
Call the Alarm AOI for the fail to stop alarm
STRS:
Total Count of Device Starts since last starts reset
VFDMaxSP: VFD Maximum Setpont
Locked by program. (ESD)
Move desired set time into the Inhibit Timer if it's not the First Scan.
Determine which Alarm has the Highest Priority when any alarm is active.
This is to determine which icon to display on HMI.
Manual Stop Command from HMI.
RTTotalHrs: Run Time Hours Total Since Last Reset.
MN:
Device Running Status
Month
If the Setpoint to be scaled is less than the min allowed setpoint, move min setpoint into output to be scaled
Monitor a STOP request for the present state to set the INTERNAL STOP
PC_MAN and PC_AUTO Stops have effect if in remote (or remote is disabled)
If remote is enabled and in local, monitor motor stop to support bumpless transfer to remote.
Motor Run Time Accumulation.
This is used to capture the seconds when motor stops and keep that total to correctly count to a minute.
STTD: Count of Starts Today
RTTodayHrs: Run Time Hours Today/Current.
Hours
Deviation Timer Remaining in Seconds
Motor Run Time Accumulcation + Motor Run Timer Elapsed time.
VFDSPReqPLC: VFD Speed Setpoint from PLC
Suppress All Alarms.
IF the motor is running, update the last run date for the motor.
VFDOut:
Output to Physical Device
Tagged Out of Service.
RTTotalMin: Run Time Minutes Since Last Reset.
Acknowledge Command from Logic to Acknowledge All Alarms in this DFB
When the Shelve Timer is Done Un-Latch the Shelve Command from HMI.
If Auto is disabled, force into manual mode.
MTR.VFDSPReqPLC: VFD Speed Setpoint from PLC
Reset Count of Starts Command from HMI.
If Manual is disabled, force into AUTO mode.
Call the Alarm AOI for the IO PLC Fault
If feedback is outside setpoint deband, active deviation fault.
Deadband is total range from over to under and scaled as percentage.
VFDSP + ( DBND * VFDMaxSP)
100 * 2
HzEnable:
1 = VFD using Hz (0-60 Hz)
0 = VFD using Percentages (0-100%)
STTD:
Count of Starts Today.
Seconds
RSRM: Restart Delay Remaining seconds.
Hours
Move a 0 into the Inhibit Timer to Finish the timer on First Scan.
MTR.ATRM: Alarm Time Remaining: Seconds Until Alarm Trips if Fault is not Cleared.
Call the Alarm AOI for the fail to start alarm
Speed Deviation Alarm Time Remaining
STTD:
Count of Starts Today
On the first scan that the current hour and minute is equal to the reset hour and minute (midnight):
Mov todays totals into yesterdays totals and clear todays totals
RTTotalMin: Run Time Minutes Since Last Reset.
RTTodayMin: Run Time Minutes Today.
Restart Delay: Seconds to inhibit motor start after motor stops.
MN:
Device Running Status
Find the shortest alarm time remaining:
Start by setting alarm time remaining very high.
Then for each alarm, if its fault is active and its time remaining is less than the current value of alarm time remaining, then set its time remaining as the overall alarm time remaining.
VFDOut: Output to Physical Device
RTTodayMin:
Run Time Minutes Today
MTR.ATRM: Alarm Time Remaining: Seconds Until Alarm Trips if Fault is not Cleared.
RTTotalHrs: Run Time Hours Since Last Reset.
RTYesterdayHrs:
Run Time Hours Yesterday.
VFDSP: VFD Speed Setpoint
RTTodayMin: Run Time Minutes Today.
MTR.VFDOut: Output to Physical Device
RTTotalMin: Run Time Minutes Since Last Reset.
Set by HMI
1= Device in Auto
0= Device in Manual
Motor Failure Alarm Time Remaining
Internal Stop Command
VFDOut:
Output to Physical Device
Fail To Start Alarm Time Remaining
Call the Alarm AOI for the Deviaiton Alarm
Manual Stop Command from HMI.
VFDSPReqPLC: VFD Speed Setpoint from PLLC
Mintes
Reset: Command from HMI to Reset all alarms on this device.
RTTodayHrs: Run Time Hours Today/Current.
Manual Acknowledge Command from HMI.
HzEnable:
1 = VFD using Hz (0-60 Hz)
0 = VFD using Percentages (0-100%)
Move Alarm Notify # to 0 if no Alarms are active.
STRS: Total Count of Device Starts since last starts reset.
if any one of the aknowledged bits are on, set the GenAlarmAcked bit
Scale Output to a 4,000-20,000 (4-20mA) signal.
Formula Assumes the following Values:
Raw Max is 20,000
Raw Min is 4,000
VFD is scaled as a Hz and not as Percentage
(((20000-4000)*VFDScale)/60)+4000
Tagged Out of Service.
Global Reset:
Used to reset all alarms in this DFB
Minutes
VFDScale: VFD Output in EU to be Scaled
Reset Runtime Command from HMI
VFDScale: VFD Output in EU to be Scaled
Auto Enable:
Set to 1 if there is an auto routine. Used to Hide or show Auto Display on HMI.
VFDSP: VFD Speed Setpoint
Un-Suppress All Alarms.
VFDScale: VFD Output in EU to be Scaled
When the one minute timer is done:
Reset the timer.
Add one to todays run time minutes.
If todays runtime minutes goes over 59, add one to todays run time hours and clear the minutes.
Add one to the total run time minutes.
If the total runtime minutes goes over 59, add one to the total run time hours and clear the minutes.
RTTodayHrs:
Run Time Hours Today / Current
Call the Alarm AOI for the Motor Failure
Device Run Command
if any one of the Annunciate bits are on, set the general GenAnnunciate bit.
Reset Count of Starts Command from HMI
If there is a PLC wide global reset, latch the local alarm reset so the global reset has the same effect as the local reset.
Month
At least one alarm on this device is active.
VFDSP - ( DBND * VFDMax SP)
100 * 2
MTR.VFDFB: Speed Indication Feedback from Device
Year
ATRM: Alarm Time Remaining: Seconds Until Alarm Trips if Fault is not Cleared
DDT for MTR VFD Ladder DFB: Motor with Variable Speed Motor, No Strings
First Integer of packed Bits
Start Command from HMI
Stop Command from HMI
True indicates blue flag should be displayed.
Start fault is active, this is not the delayed alarm
Stop fault is active, this is not the delayed alarm
Reset: Command from HMI to Reset all alarms on this device.
Acknowledge Command from Logic to Acknowledge All Alarms in this DFB
Remote: 1 = Device In Remote 0 = Device In Local
Device Running Status
Motor Fail Status from Motor Controller
1 remote/local input wired 0 = not wired
Set to 1 if there is an auto routine. Used to hide or show Auto display on HMI
1 = VFD using Hz (0-60 Hz) 0 = VFD using Percentages (0-100%)
1 = Manual Mode Disabled, Always in Auto 0 = Operator may run device in Auto or Manual
Used to reset all alarms in the DFB
Set by HMI 0 = Device in Manual 1 Device in Auto
Second Integer of packed Bits
Locked by program (ESD)
Tagged Out of Service
Auto Start from Auto Logic
Auto Stop from Auto Logic
Reset Runtime Command from HMI
Reset Count of Starts Command from HMI
Device Failed to Start
Device Failed to Stop
General Failure Alarm from Motor Drive
At least one alarm on this device is active.
Acknowledged: At least one alarm has been acknowledged.
At least one alarm in Device is annunciating (flash the device symbol)
All Alarms can be reset
Fail to Start, Fail to Stop or Motor Failure alarm is active
Device Run Command
Device is ready for auto control
Third Integer of packed Bits
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
General Alarm Shelved State
General Alarm Suppressed State
Deviation Alarm from Logic
Deviation fault is active, this is not the delayed alarm
Shelve Command from HMI
Suppress Command from HMI
Suppress Alarm from Program Control
UnSuppress Alarm from Program Control
Unshelve Alarm from Program Control
Fourth Integer of packed Bits (SPARE)
Spare Integer
Spare Integer
Run Time Hours Today/Current
Run Time Minutes Today
Run Time Hours Total Since Last Reset
Run Time Minutes Since Last Reset
Run Time Hours Yesterday
Run Time Minutes Yesterday
Total Count of Device Starts since last starts reset
Count of Starts Today
Count of Starts Yesterday
Time the runtime was last reset
Year
Month
Day
Hours
Minutes
Seconds
Time the starts counts was last reset
Year
Month
Day
Hours
Minutes
Seconds
Date Last Run for HMI display
Month
Day
Year
Hours
Minutes
Seconds
Restart Delay: Seconds to inhibit motor start after motor stops
Restart Delay Remaining: in seconds
Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
Output to Physical Device
Fail to Start Alarm DDT
Fail to Sop Alarm DDT
Motor Failure Alarm DDT
PLC Fault Alarm DDT
Speed Deviation Alarm DDT
Faceplate Display Index
Maximum Value of Deviation before Timer begins
Minimum Value of Deviation before Timer begins
Deviation Timer Remain in Seconds
VFD Output in EU to be Scaled
Speed Indication Feedback from Device
VFD MAX SPEED SETPOINT
VFD MIN SPEED SETPOINT
VFD Speed Setpoint
Deadband for Deviation Timer
VFD Speed Request from PLC
Combined Alarm Value Notification for HMI
Two Output Valve w/ Actuator Fault and Program Override
1 = remote/local input wired 0 = not wired
Remote: 1 = Device In Remote 0 = Device In Local
Set to 1 if there is an auto routine. Used to hide or show Auto display on HMI
1 = Open and Close Feedback is Present 0 = No Feedback
Valve Open Status from device limit switch (Discrete Input to PLC)
Valve Closed Status from device limit switch (Discrete Input to PLC)
Valve Failure
Locked out by program
Auto Open from Auto Logic
Auto Close from Auto Logic
Used to reset all alarms in the PLC
PLC First Scan
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
System Time
Two Output Valve w/ Actuator Fault and Program Override DDT
Suppress Alarm from Program Control
UnSuppress Alarm from Program Control
Unshelve Alarm from Program Control
At least one alarm on this device is active.
At least one alarm in Device is annunciating (flash the device symbol)
Acknowledged: At least one alarm has been acknowledged.
At least one alarm is latched and all latched alarms are resetable
Valve Close Command
Valve Open Command
Failed to Open Alarm is Active
Failed to Close Alarm is Active
Actuator Fault Alarm is Active
Device is ready for auto control
Valve Cycle Count
Latched HMI CLOS Command
Latched HMI OPEN Command
Fail To Open Alarm DFB
Fail To Close Alarm DFB
Actuator Fault Alarm DFB
PLC Fault Alarm DFB
Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
Call the Alarm AOI for the fail to close alarm
If Auto is disabled, force into manual mode.
Call the Alarm AOI for the fail to open alarm
Find the shortest alarm time remaining:
Start by setting alarm time remaining very high.
Then for each alarm, if its fault is active and its time remaining is less than the current value of alarm time remaining, then set its time remaining as the overall alarm time remaining.
Clear operator control bits
if in alarm and all alarms in the alarm array are either not in alarm or resetable, then the overall device is resetable.
Year
Latch the internal Close command when the close command is issued from the HMI unless:
In local mode (bypass this latch break if no local/remote feedback),
In auto Mode, If Close feedback is present, If HMI stop command is recieved.
This will allow bumpless transfer from Auto to Manual and reverse.
The interlock will call for Close regardless of Auto/Manual mode.
Manual Open Command from HMI.
If there is a PLC wide global reset, latch the local alarm reset so the global reset has the same effect as the local reset.
Device is ready for auto control if it is in remote, in auto, not in alarm, not tagged out of service, and not interlocked.
This prescan routine is only exicuted before the first scan or on changes from program mode to run mode:
Clear operator control bits
Move Alarm Notify # to 0 if no Alarms are active.
Month
Determine which Alarm has the Highest Priority when any alarm is active.
This is to determine which icon to display on HMI.
Call the Alarm AOI for the IO PLC Fault
Increment Cycle Count when valve is Closed
if any one of the aknowledged bits are on, set the GenAlarmAcked bit
Day
Alarm Reset Command from HMI
Call the Alarm AOI for the actuator fault alarm
if any one of the Annunciate bits are on, set the general GenAnnunciate bit.
Year
Hour
Reset Valve Cycle Count
Month
Output the Open Command to the Valve:
Block Open output if out of service.
Reset Valve Cycle Count on Operator Request
Manual Stop Command from HMI.
Day
Output the Close Command to the Valve:
Block close output if out of service.
IF valve is commanded to move then update the last run date.
Acknowledge: HMI Input to reset the AlarmAckd bit.
Map items from DDT
Map Items to DDT
Minute
if any one of the Alarms are on, set the general GenAlarm bit
Latch the internal Open command when the open command is issued from the HMI unless:
In local mode (bypass this latch break if no local/remote feedback),
In auto Mode, If Open feedback is present, If HMI stop command is recieved.
This will allow bumpless transfer from Auto to Manual and reverse.
Manual Close Command from HMI.
DDT for VLV2C Ladder DFB: Two Output Valve w/ Actuator Fault and Program Override, No Strings
First Integer of packed Bits
1 = remote/local input wired 0 = not wired
Set to 1 if there is an auto routine. Used to hide or show Auto display on HMI
1 = Open and Close Feedback is Present 0 = No Feedback
Remote: 1 = Device In Remote 0 = Device In Local
Valve Failure
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
Valve Open Status from device limit switch (Discrete Input to PLC)
Valve Closed Status from device limit switch (Discrete Input to PLC)
Used to reset all alarms in the PLC
Invoke Program Override - Regardless of Auto/Manual status
Locked out by program
Tagged Out of Service
Auto Open from Auto Logic
Auto Close from Auto Logic
Valve Open Command
Valve Close Command
Second Integer of packed Bits
At least one alarm on this device is active.
At least one alarm in Device is annunciating (flash the device symbol)
Acknowledged: At least one alarm has been acknowledged.
At least one alarm is latched and all latched alarms are resetable
Failed to Open Alarm is Active
Failed to Close Alarm is Active
Actuator Fault Alarm is Active
Device is ready for auto control
Set by HMI 0 = Device in Manual 1 = Device in Auto
Acknowledge: HMI input to reset the AlarmAckd bit.
Alarm Reset Command from HMI
Manual Close Command from HMI
Manual Open Command from HMI
Reset Valve Cycle Count
May not be in alarm due to alarm delay
May not be in alarm due to alarm delay
Third Integer of Packed Bits.
True indicates blue flag should be displayed.
Manual Stop Command from HMI
May not be in alarm due to alarm delay
Set if any of the I/O modules associated with the monitoring or control of the equipment has faulted.
Shelve Command from HMI
Shelved Status
Suppress Command from HMI
Suppressed Status
Suppress Alarm from Program Control
UnSuppress Alarm from Program Control
Unshelve Alarm from Program Control
1 = Interlock Enabled, 0 = Interlock Disabled
1 = Valve Failure Enabled, 0 = Valve Failure Disabled
Fourth Integer of Packed Bits. (SPARE)
Spare Integer.
Spare Integer.
Override Mode Command 1 = Close, 2 = Open
Alarm Time Remaining: Seconds Until Alarm Trips If Fault is not Cleared
Valve Cycle Count
Last Time Valve Cycle Count was Reset
Year
Month
Day
Hours
Minutes
Seconds
Faceplate Display Index
Date Last Run for HMI display
Month
Day
Year
Hours
Minutes
Seconds
Fail To Open Alarm DDT
Fail To Close Alarm DDT
Actuator Fault Alarm DDT
PLC Fault Alarm DDT
Combined Alarm Value Notification for HMI
Equipment Accum. Runtime In Hours and Tenth Of Hours DFB
Device Running feedback
Accumulated Runtime reset
Calculate Runtime in hours and tenth of hours
Total Runtime more than 32766 Hours holder
Comvert Runtime in Hours
Total Runtime in Min
Reset every 60 Seconds
Total Runtime in Second
Total Runtime Hours
Reset every hour
Flow Totalizer with Discrete Input for counting
Discrete Input pulse from flow meter
HMI Command to Reset Flow Totals
System Time
Today's Total Flow
Yesterday's Total Flow
Total Flow Since Last Reset
Used to roll today's total to yesterday's and reset today's
FQ Counter is done
Flow Total (DINT)
Flow Total Today (DINT)
Flow Total Yesterday (DINT)
Internal Flow Totalizer Reset
One shot used to Roll Totals
Counter used to total the resetable total
Counter used to total todays total
Convert DINTs to REALS for SCADA
Latch Flow Totalizer Reset Bit From HMI
Count pulses for resettable total
Count pulses for today's total
Roll todays total to yesterdays total
Determine if a Day Roll Over will take place this scan
Enhanced Device DDT for embedded M580 DTM (with standalone PLC)
CRA health (Drop 1 to 31)
Reserved
Health bits for CRA Safe Task objects
Health for DIO (New field name)
CIMR/CIDR Object health bits
Ethernet status
Link up/down for Ethernet port 1
Link up/down for Ethernet port 2
Link up/down for Ethernet port 3
Link up/down for Ethernet backplane port
Link up/down for HSBY port
Redundancy status / backup path available
Scanner OK and scanning at least 1 equipment (if at least 1 equipment configured)
0: one or more services not operating normally / 1: all operational
1: No traffic overload detected / 0: Traffic overload detected (ex: broadcast storm). Check your network topology and configuration.
One bit for each user-observable feature
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
Main IP address status (0 in case of duplicate IP or no IP assigned)
Ethernet backplane hardware status (0: failure, 1: OK)
Ethernet backplane error (0: error, 1: OK)
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
EIP adapter (server) service 0: service not operating normally / 1: service operating normally or disabled
One bit for each user-observable feature
IP address A/B status (0 in case of duplicate IP or no IP assigned)
LLDP service status
0: event log service not operating normally / 1: event log service operating normally or disabled
1: No acknowledgement received from the syslog server / 0: otherwise
Ethernet port 1 and 2 status
Ethernet port 3 and backplane port status
% of FDR server usage
Reserved
Reserved
Number of packets received on interface
Number of inbound packets that contain errors
Number of packets sent on interface
Number of outbound packets that contain errors
Signature of all files on local module FDR Server
DROP health bits (Drop 1 to 31)
Reserved
RIO health bits (1 bit per RIO up to 128)
Local Slave health bits (Local Slave 1 to 3)
DIO health bits (1 bit per DIO up to 128 DIOs)
DIO device health (1 bit per DIO up to 128 DIO)
DROP control bits (Drop 1 to 31)
Reserved
RIO control bits (1 bit per RIO up to 128)
DIO control bits (1 bit per DIO up to 128 DIOs)
Device DDT For BME NOC Factory Cast
Ethernet status
Link up/down for Ethernet port 1
Link up/down for Ethernet port 2
Link up/down for Ethernet port 3
Link up/down for Ethernet backplane port
Link up/down for HSBY port
Redundancy status / backup path available
Scanner OK and scanning at least 1 equipment (if at least 1 equipment configured)
0: one or more services not operating normally / 1: all operational
1: No traffic overload detected / 0: Traffic overload detected (ex: broadcast storm). Check your network topology and configuration.
One bit for each user-observable feature
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
Main IP address status (0 in case of duplicate IP or no IP assigned)
Ethernet backplane hardware status (0: failure, 1: OK)
Ethernet backplane error (0: error, 1: OK)
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
0: service not operating normally / 1: service operating normally or disabled
EIP adapter (server) service 0: service not operating normally / 1: service operating normally or disabled
One bit for each user-observable feature
IP address A/B status (0 in case of duplicate IP or no IP assigned)
LLDP service status
0: event log service not operating normally / 1: event log service operating normally or disabled
1: No acknowledgement received from the syslog server / 0: otherwise
Ethernet port 1 and 2 status
Ethernet port 3 and backplane port status
MSB=Major Revision, LSB=Minor Revision
% of FDR server usage
Hidden - Reserved
Number of packets received on interface
Number of inbound packets that contain errors
Number of packets sent on interface
Number of outbound packets that contain errors
Signature of all files on local module FDR Server
Health for DIO Objects
Local Slave health bits (Local Slave 1 to 16)
DIO health bits (1 bit per DIO up to 128 DIOs. 112 - 127 are reserved for future extension)
DIO device health (1 bit per DIO up to 128 DIO)
DIO control bits (1 bit per DIO up to 128 DIOs. 112 - 127 are reserved for future extension)
Reserved
Health of Distributed IO Objects
Device Connection health bits 2 to 17
Device Connection health bits 18 to 33
Device Connection health bits 34 to 49
Device Connection health bits 50 to 65
Device Connection health bits 66 to 81
Device Connection health bits 82 to 97
Device Connection health bits 98 to 113
Device Connection health bits 114 to 129
Device Connection health bits 130 to 145
Device Connection health bits 146 to 161
Device Connection health bits 162 to 511
Device Connection health bits 178 to 193
Device Connection health bits 194 to 209
Device Connection health bits 210 to 225
Device Connection health bits 226 to 241
Device Connection health bits 242 to 257
Device DDT For BME NOC Factory Cast
Output Variables
Device DDT For BME NOC Factory Cast
Output Variables
Device DDT For BME NOC Factory Cast
Global Freshness
Freshness of Object
Reserved
Input Variables
Unused Variable
Device DDT For BME NOC Factory Cast
Global Freshness
Freshness of Object
Reserved
Input Variables
Unused Variable
Device DDT For BME NOC Factory Cast
Global Freshness
Freshness of Object
Reserved
Input Variables
Unused Variable
Device DDT For BME NOC Factory Cast
Global Freshness
Freshness of Object
Freshness of Object
Reserved
Input Variables
Unused Variable
Device DDT For BME NOC Factory Cast
Global Freshness
Freshness of Object
Reserved
Input Variables
Unused Variable
Device DDT For BME NOC Factory Cast
Global Freshness
Freshness of Object
Reserved
Input Variables
Device DDT For BME NOC Factory Cast
Global Freshness
Freshness of Object
Reserved
Input Variables
Device DDT For BME NOC Factory Cast
Global Freshness
Freshness of Object
Reserved
Input Variables