type,address,name,data_type,control_address,pics_address,pics_data_type,notes
|
||||
Input_Register,309541,CB_Postion,uint16,409541,,,"0_open, 1_closed, 2_tripped"
|
||||
Holding_Register,409541,CB_Postion_ovr,uint16,,410001,Integer,"0_open, 1_closed, 2_tripped"
|
||||
|
@@ -52,7 +52,7 @@ Input_Register,31232,Unit_A_DrainValve2,uint16,41232,,,
|
||||
Holding_Register,41232,Unit_A_DrainValve2_Ovr,uint16,,410035,Integer,
|
||||
,,,,,,,
|
||||
Input_Register,31233,Unit_B_DrainValve2,uint16,41233,,,
|
||||
Holding_Register,41233,Unit_B_DrainValve2_Ovr,uint16,,410037,Integer
|
||||
Holding_Register,41233,Unit_B_DrainValve2_Ovr,uint16,,410037,Integer,
|
||||
,,,,,,,
|
||||
Holding_Register,40003,Humidity_Setpoint,uint16,,410039,Integer,
|
||||
,,,,,,,
|
||||
|
||||
|
Can't render this file because it has a wrong number of fields in line 55.
|
26
Neptronic_SKE4_MB_v3.csv
Normal file
26
Neptronic_SKE4_MB_v3.csv
Normal file
@@ -0,0 +1,26 @@
|
||||
type,address,name,data_type,control_address,pics_address,pics_data_type,notes
|
||||
Discrete_Input,10008,Sts_PumpAlarm,bool,18,,,
|
||||
Coil,18,Sts_PumpAlarm_ctrl,bool,,430001,Integer,
|
||||
Discrete_Input,10016,Supply_Valve_Timer_Alarm,bool,16,,,
|
||||
Coil,16,Supply_Valve_Timer_Alarm_ctrl,bool,,430005,Integer,
|
||||
Discrete_Input,10041,Sts_HumidiStat,bool,41,,,
|
||||
Coil,41,Sts_HumidiStat_ctrl,bool,,430009,Integer,
|
||||
Input_Register,30044,Operation_Mode,uint32,43044,,,
|
||||
Holding_Register,43044,Operation_Mode_ctrl,uint32,,430013,Float,Act Op Mode - Config*Off*Dry Pad*Switch Off*
|
||||
Input_Register,30057,Space_Temp,uint32,43057,,,
|
||||
Holding_Register,43057,Space_Temp_ctrl,uint32,,430017,Float,
|
||||
Input_Register,30060,Space_Dewpoint,uint32,43060,,,
|
||||
Holding_Register,43060,Space_Dewpoint_ctrl,uint32,,430021,Float,
|
||||
Holding_Register,40008,Operation_Mode_Switch,uint32,,430025,Float,Op Mode Switch - Auto*Off*On
|
||||
Holding_Register,406005,Relative_Humidity,uint32,,430029,Float,Relative Humidity Sensor Value
|
||||
Holding_Register,406030,Relative_Humidity_SP,uint32,,430033,Float,Humidity Setpoint
|
||||
Holding_Register,410001,Flow_Alarm,uint16,,430037,Integer,Optional Flow Indicator Alarm - Normal * Alarm
|
||||
Holding_Register,410005,Sts_Leak,uint16,,430041,Integer,Water Leak Detection
|
||||
Holding_Register,411012,Fan_Status,uint16,,430045,Integer,SDU Fan - Off * On
|
||||
Holding_Register,412005,Fan_Alarm,uint16,,430049,Integer,SDU Fan Fault - Normal * Alarm
|
||||
Holding_Register,415015,System_Status,uint16,,430053,Integer,
|
||||
Holding_Register,415021,Boiler_Alarm,uint16,,430057,Integer,0 = Normal 1 = FailedPump 2 =
|
||||
Holding_Register,415025,Sts_Oper,uint16,,430061,Integer,"0=Off, 1=On"
|
||||
Coil,1,OCmd_ResetAckAll,bool,,430065,Integer,Acknowledge All Alarms/Reset
|
||||
Coil,10,OCmd_Stop,bool,,430069,Integer,Remote Stop (Modbus)
|
||||
Coil,12,OCmd_Start,bool,,430073,Integer,Remote Start (Modbus)
|
||||
|
25
PM9000_Modbus_v3.csv
Normal file
25
PM9000_Modbus_v3.csv
Normal file
@@ -0,0 +1,25 @@
|
||||
type,address,name,data_type,control_address,pics_address,pics_data_type,notes
|
||||
Holding_Register,402700,kWh,uint32,,410001,Float,Energy Total (kWh)
|
||||
Holding_Register,403000,Amps_A,uint32,,410005,Float,Current A
|
||||
Holding_Register,403002,Amps_B,uint32,,410009,Float,Current B
|
||||
Holding_Register,403004,Amps_C,uint32,,410013,Float,Current C
|
||||
Holding_Register,403006,Amps_N,uint32,,410017,Float,Current N
|
||||
Holding_Register,403020,Volts_AB,uint32,,410021,Float,Volts AB
|
||||
Holding_Register,403022,Volts_BC,uint32,,410025,Float,Volts BC
|
||||
Holding_Register,403024,Volts_CA,uint32,,410029,Float,Volts CA
|
||||
Holding_Register,403028,Volts_AN,uint32,,410033,Float,Volts AN
|
||||
Holding_Register,403030,Volts_BN,uint32,,410037,Float,Volts BN
|
||||
Holding_Register,403032,Volts_CN,uint32,,410041,Float,Volts CN
|
||||
Holding_Register,403052,Voltage_Unbalanced,uint32,,410045,Float,Voltage Unbalanced
|
||||
Holding_Register,403060,kW,uint32,,410049,Float,Real Power Total (kW)
|
||||
Holding_Register,403076,kVA,uint32,,410053,Float,Apparent Power Total (kVA)
|
||||
Holding_Register,403110,Freq,uint32,,410057,Float,Frequency
|
||||
Holding_Register,403150,PF,uint32,,410061,Float,Power Factor -Total
|
||||
Holding_Register,409027,DI_S1,uint32,,410065,Float,
|
||||
Holding_Register,409029,DI_S2,uint32,,410069,Float,
|
||||
Holding_Register,409031,DI_S3,uint32,,410073,Float,
|
||||
Holding_Register,409033,DI_S4,uint32,,410077,Float,
|
||||
Holding_Register,409035,DI_S5,uint32,,410081,Float,
|
||||
Holding_Register,409037,DI_S6,uint32,,410085,Float,
|
||||
Holding_Register,409039,DI_S7,uint32,,410089,Float,
|
||||
Holding_Register,409041,DI_S8,uint32,,410093,Float,
|
||||
|
124
Petra_PAH600.csv
Normal file
124
Petra_PAH600.csv
Normal file
@@ -0,0 +1,124 @@
|
||||
type,address,name,data_type,control_address,pics_address,pics_data_type,notes,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,100051,Water_Detected_Alarm,bool,51,,,Unit flooding detector alarm,,,,,,,,,,,,,,51 bools,,
|
||||
Coil,51,_Water_Detected_Alarm,bool,,,,Unit flooding detector alarm,,,,,,,,,,,,,,57 uints,,57
|
||||
Discrete_Input,100118,High_Temperature_Supply_Air,bool,118,,,High supply air temperature alarm,,,,,,,,,,,,,,,,36
|
||||
Coil,118,_High_Temperature_Supply_Air,bool,,,,High supply air temperature alarm,,,,,,,,,,,,,,,,21
|
||||
Discrete_Input,100122,Low_Temperature_Supply_Air,bool,122,,,Low supply air temperature alarm,,,,,,,,,,,,,,,,
|
||||
Coil,122,_Low_Temperature_Supply_Air,bool,,,,Low supply air temperature alarm,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,100131,Fan_Alarm1,bool,131,,,Fan Alarm 1,,,,,,,,,,,,,,,,
|
||||
Coil,131,_Fan_Alarm1,bool,,,,Fan Alarm 1,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,100132,Fan_Alarm2,bool,132,,,Fan Alarm 2,,,,,,,,,,,,,,,,
|
||||
Coil,132,_Fan_Alarm2,bool,,,,Fan Alarm 2,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,100133,Fan_Alarm3,bool,133,,,Fan Alarm 3,,,,,,,,,,,,,,,,
|
||||
Coil,133,_Fan_Alarm3,bool,,,,Fan Alarm 3,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,100134,Fan_Alarm4,bool,134,,,Fan Alarm 4,,,,,,,,,,,,,,,,
|
||||
Coil,134,_Fan_Alarm4,bool,,,,Fan Alarm 4,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,100135,Fan_Alarm5,bool,135,,,Fan Alarm 5,,,,,,,,,,,,,,,,
|
||||
Coil,135,_Fan_Alarm5,bool,,,,Fan Alarm 5,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,100136,Fan_Alarm6,bool,136,,,Fan Alarm 6,,,,,,,,,,,,,,,,
|
||||
Coil,136,_Fan_Alarm6,bool,,,,Fan Alarm 6,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,100146,Supply_Sensor_Failure_Alarm,bool,146,,,Supply air temperature sensor fault,,,,,,,,,,,,,,,,
|
||||
Coil,146,_Supply_Sensor_Failure_Alarm,bool,,,,Supply air temperature sensor fault,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101096,Filter_Alarm,bool,1096,,,Dirty filter alarm,,,,,,,,,,,,,,,,
|
||||
Coil,1096,_Filter_Alarm,bool,,,,Dirty filter alarm,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101099,Low_Temperature_Return_Air,bool,1099,,,Low return air temperature alarm,,,,,,,,,,,,,,,,
|
||||
Coil,1099,_Low_Temperature_Return_Air,bool,,,,Low return air temperature alarm,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101245,Return_Sensor_Failure_Alarm,bool,1245,,,Return air temperature sensor fault,,,,,,,,,,,,,,,,
|
||||
Coil,1245,_Return_Sensor_Failure_Alarm,bool,,,,Return air temperature sensor fault,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101246,Humidity_Sensor_Failure_Alarm,bool,1246,,,Return air humidity sensor fault,,,,,,,,,,,,,,,,
|
||||
Coil,1246,_Humidity_Sensor_Failure_Alarm,bool,,,,Return air humidity sensor fault,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101250,Filter_Diff_Press_Sensor_Failure,bool,1250,,,Filter differential pressure sensor fault,,,,,,,,,,,,,,,,
|
||||
Coil,1250,_Filter_Diff_Press_Sensor_Failure,bool,,,,Filter differential pressure sensor fault,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101307,High_Humidity_Return_Air,bool,1307,,,High return air humidity alarm,,,,,,,,,,,,,,,,
|
||||
Coil,1307,_High_Humidity_Return_Air,bool,,,,High return air humidity alarm,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101308,Low_Humidity_Return_Air,bool,1308,,,Low return air humidity alarm,,,,,,,,,,,,,,,,
|
||||
Coil,1308,_Low_Humidity_Return_Air,bool,,,,Low return air humidity alarm,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101342,Common_Alarm,bool,1342,,,Common alarm status,,,,,,,,,,,,,,,,
|
||||
Coil,1342,_Common_Alarm,bool,,,,Common alarm status,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101360,Fan_Alarm7,bool,1360,,,Fan Alarm 7,,,,,,,,,,,,,,,,
|
||||
Coil,1360,_Fan_Alarm7,bool,,,,Fan Alarm 7,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101361,Fan_Alarm8,bool,1361,,,Fan Alarm 8,,,,,,,,,,,,,,,,
|
||||
Coil,1361,_Fan_Alarm8,bool,,,,Fan Alarm 8,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101362,Fan_Alarm9,bool,1362,,,Fan Alarm 9,,,,,,,,,,,,,,,,
|
||||
Coil,1362,_Fan_Alarm9,bool,,,,Fan Alarm 9,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101367,High_Temperature_Return_Air,bool,1367,,,High return air temperature alarm,,,,,,,,,,,,,,,,
|
||||
Coil,1367,_High_Temperature_Return_Air,bool,,,,High return air temperature alarm,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101368,Smoke_Detected,bool,1368,,,Smoke alarm status,,,,,,,,,,,,,,,,
|
||||
Coil,1368,_Smoke_Detected,bool,,,,Smoke alarm status,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101369,Fire_SD_Alarm,bool,1369,,,Fire alarm status,,,,,,,,,,,,,,,,
|
||||
Coil,1369,_Fire_SD_Alarm,bool,,,,Fire alarm status,,,,,,,,,,,,,,,,
|
||||
Discrete_Input,101370,Cond_Pump_Fail,bool,1370,,,Condensate pump alarm status,,,,,,,,,,,,,,,,
|
||||
Coil,1370,_Cond_Pump_Fail,bool,,,,Condensate pump alarm status,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Input_Register,300053,Fan1_Speed,uint16,430053,,,Speed-EC FAN#1,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430053,_Fan1_Speed,uint16,,410001,Integer,Speed-EC FAN#1,,,,,,,,,,,,,,,,
|
||||
Input_Register,300070,Return_Humidity,uint32,430070,,,Return air humidity reading,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430070,_Return_Humidity,uint32,,410005,Float,Return air humidity reading,,,,,,,,,,,,,,,,
|
||||
Input_Register,300099,Air_Supply_Temp,uint32,430099,,,Supply air temperature reading,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430099,_Air_Supply_Temp,uint32,,410009,Float,Supply air temperature reading,,,,,,,,,,,,,,,,
|
||||
Input_Register,300101,Air_Return_Temp,uint32,430101,,,Return air temperature,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430101,_Air_Return_Temp,uint32,,410013,Float,Return air temperature,,,,,,,,,,,,,,,,
|
||||
Input_Register,300106,Supply_Filter_Diff_Press,uint32,430106,,,,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430106,_Supply_Filter_Diff_Press,uint32,,410017,Float,,,,,,,,,,,,,,,,,
|
||||
Input_Register,300228,Fan2_Speed,uint16,430228,,,Speed-EC FAN#2,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430228,_Fan2_Speed,uint16,,410021,Integer,Speed-EC FAN#2,,,,,,,,,,,,,,,,
|
||||
Input_Register,300229,Fan3_Speed,uint16,430229,,,Speed-EC FAN#3,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430229,_Fan3_Speed,uint16,,410025,Integer,Speed-EC FAN#3,,,,,,,,,,,,,,,,
|
||||
Input_Register,300230,Fan4_Speed,uint16,430243,,,Speed-EC FAN#4,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430243,_Fan4_Speed,uint16,,410029,Integer,Speed-EC FAN#4,,,,,,,,,,,,,,,,
|
||||
Input_Register,300231,Fan5_Speed,uint16,430231,,,Speed-EC FAN#5,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430231,_Fan5_Speed,uint16,,410033,Integer,Speed-EC FAN#5,,,,,,,,,,,,,,,,
|
||||
Input_Register,300232,Fan6_Speed,uint16,430232,,,Speed-EC FAN#6,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430232,_Fan6_Speed,uint16,,410037,Integer,Speed-EC FAN#6,,,,,,,,,,,,,,,,
|
||||
Input_Register,300233,Fan2_Hrs,uint16,430233,,,Operating hours-EC FAN#2,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430233,_Fan2_Hrs,uint16,,410041,Integer,Operating hours-EC FAN#2,,,,,,,,,,,,,,,,
|
||||
Input_Register,300235,Fan4_Hrs,uint16,430235,,,Operating hours-EC FAN#4,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430235,_Fan4_Hrs,uint16,,410045,Integer,Operating hours-EC FAN#4,,,,,,,,,,,,,,,,
|
||||
Input_Register,300236,Fan5_Hrs,uint16,430236,,,Operating hours-EC FAN#5,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430236,_Fan5_Hrs,uint16,,410049,Integer,Operating hours-EC FAN#5,,,,,,,,,,,,,,,,
|
||||
Input_Register,300244,Fan3_Hrs,uint16,430244,,,Operating hours-EC FAN#3,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430244,_Fan3_Hrs,uint16,,410053,Integer,Operating hours-EC FAN#3,,,,,,,,,,,,,,,,
|
||||
Input_Register,300245,Fan6_Hrs,uint16,430245,,,Operating hours-EC FAN#6,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430245,_Fan6_Hrs,uint16,,410057,Integer,Operating hours-EC FAN#6,,,,,,,,,,,,,,,,
|
||||
Input_Register,300274,Fan1_Hrs,uint16,430274,,,Operating hours-EC FAN#1,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430274,_Fan1_Hrs,uint16,,410061,Integer,Operating hours-EC FAN#1,,,,,,,,,,,,,,,,
|
||||
Input_Register,300486,Fan7_Hrs,uint16,430486,,,Operating hours-EC FAN#7,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430486,_Fan7_Hrs,uint16,,410065,Integer,Operating hours-EC FAN#7,,,,,,,,,,,,,,,,
|
||||
Input_Register,300487,Fan8_Hrs,uint16,430487,,,Operating hours-EC FAN#8,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430487,_Fan8_Hrs,uint16,,410069,Integer,Operating hours-EC FAN#8,,,,,,,,,,,,,,,,
|
||||
Input_Register,300488,Fan9_Hrs,uint16,430488,,,Operating hours-EC FAN#9,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430488,_Fan9_Hrs,uint16,,410073,Integer,Operating hours-EC FAN#9,,,,,,,,,,,,,,,,
|
||||
Input_Register,300496,Cooling_Valve_Output,uint32,430496,,,Chilled water valve feedback signal,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430496,_Cooling_Valve_Output,uint32,,410077,Float,Chilled water valve feedback signal,,,,,,,,,,,,,,,,
|
||||
Input_Register,300678,Fan7_Speed,uint16,430678,,,Speed-EC FAN#7,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430678,_Fan7_Speed,uint16,,410081,Integer,Speed-EC FAN#7,,,,,,,,,,,,,,,,
|
||||
Input_Register,300679,Fan8_Speed,uint16,430679,,,Speed-EC FAN#8,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430679,_Fan8_Speed,uint16,,410085,Integer,Speed-EC FAN#8,,,,,,,,,,,,,,,,
|
||||
Input_Register,300680,Fan9_Speed,uint16,430680,,,Speed-EC FAN#9,,,,,,,,,,,,,,,,
|
||||
Holding_Register,430680,_Fan9_Speed,uint16,,410089,Integer,Speed-EC FAN#9,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Holding_Register,400005,Fan_Speed_Max_SP,uint32,,410097,Float,Setting the EC fan maximum speed,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Holding_Register,400029,Fan_Speed,uint32,,410101,Float,Fan Speed Feedback,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Holding_Register,400111,Air_Return_Temp_Alm_Hi_SP,uint32,,410105,Float,High return air temperature alarm limit,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Holding_Register,400114,Air_Return_Temp_Alm_Lo_SP,uint32,,410109,Float,Low return air temperature alarm limit,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Holding_Register,400118,Air_Supply_Temp_Alm_Hi_SP,uint32,,410113,Float,High supply air temperature alarm limit,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Holding_Register,400122,Air_Supply_Temp_Alm_Lo_SP,uint32,,410117,Float,Low supply air temperature alarm limit,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Holding_Register,400681,Air_Return_Temp_SP,uint32,,410121,Float,Return air temperature setpoint,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Holding_Register,400685,Return_Humidity_Alm_Hi_SP,uint32,,410125,Float,High return air humidity alarm limit,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Holding_Register,400689,Return_Humidity_Alm_Lo_SP,uint32,,410129,Float,Low return air humidity alarm limit,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Holding_Register,400693,Space_Temp_SP,uint32,,410133,Float,Setting the room temperature,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Holding_Register,400695,Fan_Speed_Min_SP,uint32,,410137,Float,Setting the EC fan minimum speed,,,,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,,,,,,,,,,,
|
||||
Coil,301,BMS_StartStop,bool,,,,,,,,,,,,,,,,,,,,
|
||||
|
30
Woodward_DTSC200A_Modbus.csv
Normal file
30
Woodward_DTSC200A_Modbus.csv
Normal file
@@ -0,0 +1,30 @@
|
||||
type,address,name,data_type,control_address,pics_address,pics_data_type,notes
|
||||
Holding_Register,450010,PF,uint16,,410001,Integer,
|
||||
Holding_Register,450016,Register_450016_Bits,uint16,,410003,Integer,bit 12=4096: S2_Closed_Failure; bit 13=8192: S1_Closed_Failure; bit 14=16384: S2_Open_Failure; bit 15=32768: S1_Open_Failure; Duplicate UDT address with line 31; counterpart not created.; Duplicate UDT span overlaps line 31; counterpart not created.
|
||||
Holding_Register,450025,Register_450025_Bits,uint16,,410005,Integer,bit 10=1024: S2_StartFailure; Duplicate UDT address with line 32; counterpart not created.; Duplicate UDT span overlaps line 32; counterpart not created.
|
||||
Holding_Register,450028,Register_450028_Bits,uint16,,410007,Integer,bit 8=256: SWB_Gen_Not_In_Auto; bit 11=2048: SwitchGear_Not_In_Auto
|
||||
Holding_Register,450079,Register_450079_Bits,uint16,,410009,Integer,bit 8=256: Source_2_Preferred; bit 9=512: Source_1_Preferred
|
||||
Holding_Register,450083,Register_450083_Bits,uint16,,410011,Integer,bit 3=8: Source_2_Active; bit 4=16: Source_1_Active
|
||||
Holding_Register,450086,Register_450086_Bits,uint16,,410013,Integer,bit 15=32768: Transfer_Inhibited
|
||||
Holding_Register,450092,Source_1_Amps_A,uint32,,410015,Integer,
|
||||
Holding_Register,450095,Source_1_Amps_B,uint32,,410017,Integer,
|
||||
Holding_Register,450098,Source_1_Amps_C,uint32,,410019,Integer,
|
||||
Holding_Register,450094,Source_1_kW,uint16,,410021,Integer,
|
||||
Holding_Register,450101,Source_1_MWh,uint32,,410023,Integer,
|
||||
Holding_Register,450020,Source_1_Volts_AB,uint32,,410025,Integer,
|
||||
Holding_Register,450023,Source_1_Volts_AN,uint32,,410027,Integer,
|
||||
Holding_Register,450026,Source_1_Volts_BC,uint32,,410029,Integer,
|
||||
Holding_Register,450029,Source_1_Volts_BN,uint32,,410031,Integer,
|
||||
Holding_Register,450032,Source_1_Volts_CA,uint32,,410033,Integer,
|
||||
Holding_Register,450035,Source_1_Volts_CN,uint32,,410035,Integer,
|
||||
Holding_Register,450038,Source_2_Amps_A,uint32,,410037,Integer,
|
||||
Holding_Register,450041,Source_2_Amps_B,uint32,,410039,Integer,
|
||||
Holding_Register,450044,Source_2_Amps_C,uint32,,410041,Integer,
|
||||
Holding_Register,450061,Source_2_kW,uint16,,410043,Integer,
|
||||
Holding_Register,450065,Source_2_MWh,uint32,,410045,Integer,
|
||||
Holding_Register,450002,Source_2_Volts_AB,uint32,,410047,Integer,
|
||||
Holding_Register,450005,Source_2_Volts_AN,uint32,,410049,Integer,
|
||||
Holding_Register,450008,Source_2_Volts_BC,uint32,,410051,Integer,
|
||||
Holding_Register,450011,Source_2_Volts_BN,uint32,,410053,Integer,
|
||||
Holding_Register,450014,Source_2_Volts_CA,uint32,,410055,Integer,
|
||||
Holding_Register,450017,Source_2_Volts_CN,uint32,,410057,Integer,
|
||||
|
39
York_CSM_v3.csv
Normal file
39
York_CSM_v3.csv
Normal file
@@ -0,0 +1,39 @@
|
||||
type,address,name,data_type,control_address,pics_address,pics_data_type,notes
|
||||
Discrete_Input,10175,S1_Cond_Fan_Fail,bool,175,,,
|
||||
Coil,175,S1_Cond_Fan_Fail_ctrl,bool,,,,
|
||||
Discrete_Input,10176,S2_Cond_Fan_Fail,bool,176,,,
|
||||
Coil,176,S2_Cond_Fan_Fail_ctrl,bool,,,,
|
||||
Discrete_Input,10200,Comm_Error,bool,200,,,
|
||||
Coil,200,Comm_Error_ctrl,bool,,,,
|
||||
Holding_Register,40005,System_CHW_Out,uint16,,430001,Integer,
|
||||
Holding_Register,40006,System_CHW_In,uint16,,430005,Integer,
|
||||
Holding_Register,40008,S1_Condensor_Temp,uint16,,430009,Integer,
|
||||
Holding_Register,40010,Ambient_Temp,uint16,,430013,Integer,
|
||||
Holding_Register,40012,S1_Oil_Pressure,uint16,,430021,Integer,
|
||||
Holding_Register,40013,S1_Suction_Pressure,uint16,,430025,Integer,
|
||||
Holding_Register,40014,S1_Discharge_Pressure,uint16,,430029,Integer,
|
||||
Holding_Register,40015,S1_Comp_Percent_FLA,uint16,,430033,Integer,
|
||||
Holding_Register,40016,S1_RunTime,uint16,,430037,Integer,
|
||||
Holding_Register,40017,S1_RunCount,uint16,,430041,Integer,
|
||||
Holding_Register,40021,S2_Oil_Pressure,uint16,,430045,Integer,
|
||||
Holding_Register,40022,S2_Suction_Pressure,uint16,,430049,Integer,
|
||||
Holding_Register,40023,S2_Discharge_Pressure,uint16,,430053,Integer,
|
||||
Holding_Register,40024,S2_Comp_Percent_FLA,uint16,,430057,Integer,
|
||||
Holding_Register,40025,S2_RunTime,uint16,,430061,Integer,
|
||||
Holding_Register,40026,S2_RunCount,uint16,,430065,Integer,
|
||||
Holding_Register,40030,S1_Chiller_OP_Code,uint16,,430069,Integer,
|
||||
Holding_Register,40031,S1_Chiller_Fault_Code,uint16,,430073,Integer,
|
||||
Holding_Register,40032,S2_Chiller_OP_Code,uint16,,430077,Integer,
|
||||
Holding_Register,40033,S2_Chiller_Fault_Code,uint16,,430081,Integer,
|
||||
Holding_Register,40040,Chiller_Local_SP,uint16,,430085,Integer,
|
||||
Holding_Register,40050,S2_Condensor_Temp,uint16,,430089,Integer,
|
||||
Holding_Register,40112,S1_Suction_Temperature,uint16,,430093,Integer,Suction Temperature of System 1
|
||||
Holding_Register,40113,S1_Saturation_Suction_Temp,uint16,,430097,Integer,Saturation Suction Temperature of System 1
|
||||
Holding_Register,40114,S1_Suction_Super_Heat,uint16,,430101,Integer,Suction Superheat of System 1
|
||||
Holding_Register,40116,S2_Suction_Temperature,uint16,,430105,Integer,Suction Temperature of System 2
|
||||
Holding_Register,40117,S2_Saturation_Suction_Temp,uint16,,430109,Integer,Saturation Suction Temperature of System 2
|
||||
Holding_Register,40118,S2_Suction_Super_Heat,uint16,,430113,Integer,Suction Superheat of System 2
|
||||
Holding_Register,40141,S1_Fan_kW,uint16,,430117,Integer,
|
||||
Holding_Register,40142,S1_Comp_kW,uint16,,430121,Integer,
|
||||
Holding_Register,40143,S2_Fan_kW,uint16,,430125,Integer,
|
||||
Holding_Register,40144,S2_Comp_kW,uint16,,430129,Integer,
|
||||
|
41
York_CSMwTES_v3.csv
Normal file
41
York_CSMwTES_v3.csv
Normal file
@@ -0,0 +1,41 @@
|
||||
type,address,name,data_type,control_address,pics_address,pics_data_type,notes
|
||||
Discrete_Input,10175,S1_Cond_Fan_Fail,bool,0175,410001,Boolean,
|
||||
Discrete_Input,10176,S2_Cond_Fan_Fail,bool,0176,410005,Boolean,
|
||||
Discrete_Input,10200,Comm_Error,bool,0200,410009,Boolean,
|
||||
Holding_Register,40005,System_CHW_Out,uint16,,410013,Integer,
|
||||
Holding_Register,40006,System_CHW_In,uint16,,410017,Integer,
|
||||
Holding_Register,40008,S1_Condensor_Temp,uint16,,410021,Integer,
|
||||
Holding_Register,40010,Ambient_Temp,uint16,,410025,Integer,
|
||||
Holding_Register,40012,S1_Oil_Pressure,uint16,,410033,Integer,
|
||||
Holding_Register,40013,S1_Suction_Pressure,uint16,,410037,Integer,
|
||||
Holding_Register,40014,S1_Discharge_Pressure,uint16,,410041,Integer,
|
||||
Holding_Register,40015,S1_Comp_Percent_FLA,uint16,,410045,Integer,
|
||||
Holding_Register,40016,S1_RunTime,uint16,,410049,Integer,
|
||||
Holding_Register,40017,S1_RunCount,uint16,,410053,Integer,
|
||||
Holding_Register,40021,S2_Oil_Pressure,uint16,,410057,Integer,
|
||||
Holding_Register,40022,S2_Suction_Pressure,uint16,,410061,Integer,
|
||||
Holding_Register,40023,S2_Discharge_Pressure,uint16,,410065,Integer,
|
||||
Holding_Register,40024,S2_Comp_Percent_FLA,uint16,,410069,Integer,
|
||||
Holding_Register,40025,S2_RunTime,uint16,,410073,Integer,
|
||||
Holding_Register,40026,S2_RunCount,uint16,,410077,Integer,
|
||||
Holding_Register,40030,S1_Chiller_OP_Code,uint16,,410081,Integer,
|
||||
Holding_Register,40031,S1_Chiller_Fault_Code,uint16,,410085,Integer,
|
||||
Holding_Register,40032,S2_Chiller_OP_Code,uint16,,410089,Integer,
|
||||
Holding_Register,40033,S2_Chiller_Fault_Code,uint16,,410093,Integer,
|
||||
Holding_Register,40040,Chiller_Local_SP,uint16,,410097,Integer,
|
||||
Holding_Register,40050,S2_Condensor_Temp,uint16,,410101,Integer,
|
||||
Holding_Register,40141,S1_Fan_kW,uint16,,410105,Integer,
|
||||
Holding_Register,40142,S1_Comp_kW,uint16,,410109,Integer,
|
||||
Holding_Register,40143,S2_Fan_kW,uint16,,410113,Integer,
|
||||
Holding_Register,40144,S2_Comp_kW,uint16,,410117,Integer,
|
||||
Discrete_Input,10066,Chiller_Alarm,bool,0066,410121,Integer,
|
||||
Input_Register,30131,FREE_COOLING_MODE_AV,uint16,430131,,,
|
||||
Input_Register,30166,FREE_COOLING_VALVE,uint16,430166,,,
|
||||
Holding_Register,40027,VSD_OUTPUT_FREQUENCY,uint16,,410125,Integer,
|
||||
Coil,0175,S1_Cond_Fan_Fail_ctrl,bool,,,,
|
||||
Coil,0176,S2_Cond_Fan_Fail_ctrl,bool,,,,
|
||||
Coil,0200,Comm_Error_ctrl,bool,,,,
|
||||
Coil,0066,Chiller_Alarm_ctrl,bool,,410129,Integer,
|
||||
Holding_Register,430131,FREE_COOLING_MODE_AV_ctrl,uint16,,410133,Integer,
|
||||
Holding_Register,430166,FREE_COOLING_VALVE_ctrl,uint16,,410137,Integer,
|
||||
Holding_Register,440027,VSD_OUTPUT_FREQUENCY_ctrl,uint16,,410141,Integer,
|
||||
|