1typeaddressnamedata_typecontrol_addresspics_addresspics_data_typenotes
2
3Coil000071Ground_Overcurrent_FltboolCoil to trigger Groud Overcurrent
4Discrete_Input100071Ground_Overcurrentbool000071Alarm for Ground Overcurrent
5
6Coil000070Neutral_Overcurrent_FltboolCoil to trigger Neutral Overcurrent
7Discrete_Input100070Neutral_Overcurrentbool000070Alarm for Neutral Overcurrent
8
9Coil000066Panel_Overvoltage_FltboolCoil to trigger Panel Overvoltage
10Discrete_Input100066Panel_Overvoltagebool000066Alarm for Panel Overvoltage
11
12Coil000068Phase_Overcurrent_FltboolCoil to trigger Phase Overcurrent
13Discrete_Input100068Phase_Overcurrentbool000068Alarm for Phase Overcurrent
14
15Coil000069Phase_Overcurrent_Wrn_FltboolCoil to trigger Phase Overcurrent Warning
16Discrete_Input100069Phase_overcurrent_Wrnbool000069Alarm for Phase Overcurrent Warning
17
18Coil000065Summary_Alm_FltboolCoil to trigger Summary Alarm
19Discrete_Input100065Summary_Almbool000065Alarm for Summary
20
21Coil000067Panel_Undervoltage_FltboolCoil to trigger Panel Undervoltage
22Discrete_Input100067Panel_Undervoltagebool000067Alarm for Panel Undervoltage
23
24Holding_Register41110Amps_Auint16430001IntegerAmps_A
25Holding_Register41111Amps_Buint16430003IntegerAmps_B
26Holding_Register41112Amps_Cuint16430005IntegerAmps_C
27Holding_Register41113Amps_Nuint16430007IntegerAmps_N
28Holding_Register41114Amps_Guint16430009IntegerAmps_G
29
30Input_Register300463Breaker_Columnsuint16400463Breaker_Columns
31Holding_Register400463Breaker_Columns_Ovruint16430713IntegerBreaker_Columns_Ovr
32
33Holding_Register420657CT01_Ampsuint16430011IntegerCT01_Amps
34Holding_Register420001CT01_kWuint16430013IntegerCT01_kW
35Holding_Register420821CT01_kWHuint32430015FloatCT01_kWH
36Holding_Register420698CT02_Ampsuint16430019IntegerCT02_Amps
37Holding_Register420042CT02_kWuint16430021IntegerCT02_kW
38Holding_Register420903CT02_kWHuint32430023FloatCT02_kWH
39Holding_Register420658CT03_Ampsuint16430027IntegerCT03_Amps
40Holding_Register420002CT03_kWuint16430029IntegerCT03_kW
41Holding_Register420823CT03_kWHuint32430031FloatCT03_kWH
42Holding_Register420699CT04_Ampsuint16430035IntegerCT04_Amps
43Holding_Register420043CT04_kWuint16430037IntegerCT04_kW
44Holding_Register420905CT04_kWHuint32430039FloatCT04_kWH
45Holding_Register420659CT05_Ampsuint16430043IntegerCT05_Amps
46Holding_Register420003CT05_kWuint16430045IntegerCT05_kW
47Holding_Register420825CT05_kWHuint32430047FloatCT05_kWH
48Holding_Register420700CT06_Ampsuint16430051IntegerCT06_Amps
49Holding_Register420044CT06_kWuint16430053IntegerCT06_kW
50Holding_Register420907CT06_kWHuint32430055FloatCT06_kWH
51Holding_Register420660CT07_Ampsuint16430059IntegerCT07_Amps
52Holding_Register420004CT07_kWuint16430061IntegerCT07_kW
53Holding_Register420827CT07_kWHuint32430063FloatCT07_kWH
54Holding_Register420701CT08_Ampsuint16430067IntegerCT08_Amps
55Holding_Register420045CT08_kWuint16430069IntegerCT08_kW
56Holding_Register420911CT08_kWHuint32430071FloatCT08_kWH
57Holding_Register420661CT09_Ampsuint16430075IntegerCT09_Amps
58Holding_Register420005CT09_kWuint16430077IntegerCT09_kW
59Holding_Register420829CT09_kWHuint32430079FloatCT09_kWH
60Holding_Register420702CT10_Ampsuint16430083IntegerCT10_Amps
61Holding_Register420046CT10_kWuint16430085IntegerCT10_kW
62Holding_Register420913CT10_kWHuint32430087FloatCT10_kWH
63Holding_Register420662CT11_Ampsuint16430091IntegerCT11_Amps
64Holding_Register420006CT11_kWuint16430093IntegerCT11_kW
65Holding_Register420831CT11_kWHuint32430095FloatCT11_kWH
66Holding_Register420703CT12_Ampsuint16430099IntegerCT12_Amps
67Holding_Register420047CT12_kWuint16430101IntegerCT12_kW
68Holding_Register420915CT12_kWHuint32430103FloatCT12_kWH
69Holding_Register420663CT13_Ampsuint16430107IntegerCT13_Amps
70Holding_Register420007CT13_kWuint16430109IntegerCT13_kW
71Holding_Register420833CT13_kWHuint32430111FloatCT13_kWH
72Holding_Register420704CT14_Ampsuint16430115IntegerCT14_Amps
73Holding_Register420048CT14_kWuint16430117IntegerCT14_kW
74Holding_Register420917CT14_kWHuint32430119FloatCT14_kWH
75Holding_Register420664CT15_Ampsuint16430123IntegerCT15_Amps
76Holding_Register420008CT15_kWuint16430125IntegerCT15_kW
77Holding_Register420835CT15_kWHuint32430127FloatCT15_kWH
78Holding_Register420705CT16_Ampsuint16430131IntegerCT16_Amps
79Holding_Register420049CT16_kWuint16430133IntegerCT16_kW
80Holding_Register420919CT16_kWHuint32430135FloatCT16_kWH
81Holding_Register420665CT17_Ampsuint16430139IntegerCT17_Amps
82Holding_Register420009CT17_kWuint16430141IntegerCT17_kW
83Holding_Register420837CT17_kWHuint32430143FloatCT17_kWH
84Holding_Register420706CT18_Ampsuint16430147IntegerCT18_Amps
85Holding_Register420050CT18_kWuint16430149IntegerCT18_kW
86Holding_Register420921CT18_kWHuint32430151FloatCT18_kWH
87Holding_Register420666CT19_Ampsuint16430155IntegerCT19_Amps
88Holding_Register420010CT19_kWuint16430157IntegerCT19_kW
89Holding_Register420839CT19_kWHuint32430159FloatCT19_kWH
90Holding_Register420707CT20_Ampsuint16430163IntegerCT20_Amps
91Holding_Register420051CT20_kWuint16430165IntegerCT20_kW
92Holding_Register420923CT20_kWHuint32430167FloatCT20_kWH
93Holding_Register420667CT21_Ampsuint16430171IntegerCT21_Amps
94Holding_Register420011CT21_kWuint16430173IntegerCT21_kW
95Holding_Register420841CT21_kWHuint32430175FloatCT21_kWH
96Holding_Register420708CT22_Ampsuint16430179IntegerCT22_Amps
97Holding_Register420052CT22_kWuint16430181IntegerCT22_kW
98Holding_Register420925CT22_kWHuint32430183FloatCT22_kWH
99Holding_Register420668CT23_Ampsuint16430187IntegerCT23_Amps
100Holding_Register420012CT23_kWuint16430189IntegerCT23_kW
101Holding_Register420843CT23_kWHuint32430191FloatCT23_kWH
102Holding_Register420709CT24_Ampsuint16430195IntegerCT24_Amps
103Holding_Register420053CT24_kWuint16430197IntegerCT24_kW
104Holding_Register420927CT24_kWHuint32430199FloatCT24_kWH
105Holding_Register420669CT25_Ampsuint16430203IntegerCT25_Amps
106Holding_Register420013CT25_kWuint16430205IntegerCT25_kW
107Holding_Register420845CT25_kWHuint32430207FloatCT25_kWH
108Holding_Register420710CT26_Ampsuint16430211IntegerCT26_Amps
109Holding_Register420054CT26_kWuint16430213IntegerCT26_kW
110Holding_Register420929CT26_kWHuint32430215FloatCT26_kWH
111Holding_Register420670CT27_Ampsuint16430219IntegerCT27_Amps
112Holding_Register420014CT27_kWuint16430221IntegerCT27_kW
113Holding_Register420847CT27_kWHuint32430223FloatCT27_kWH
114Holding_Register420711CT28_Ampsuint16430227IntegerCT28_Amps
115Holding_Register420055CT28_kWuint16430229IntegerCT28_kW
116Holding_Register420931CT28_kWHuint32430231FloatCT28_kWH
117Holding_Register420671CT29_Ampsuint16430235IntegerCT29_Amps
118Holding_Register420015CT29_kWuint16430237IntegerCT29_kW
119Holding_Register420849CT29_kWHuint32430239FloatCT29_kWH
120Holding_Register420712CT30_Ampsuint16430243IntegerCT30_Amps
121Holding_Register420056CT30_kWuint16430245IntegerCT30_kW
122Holding_Register420933CT30_kWHuint32430247FloatCT30_kWH
123Holding_Register420672CT31_Ampsuint16430251IntegerCT31_Amps
124Holding_Register420016CT31_kWuint16430253IntegerCT31_kW
125Holding_Register420851CT31_kWHuint32430255FloatCT31_kWH
126Holding_Register420713CT32_Ampsuint16430259IntegerCT32_Amps
127Holding_Register420057CT32_kWuint16430261IntegerCT32_kW
128Holding_Register420935CT32_kWHuint32430263FloatCT32_kWH
129Holding_Register420673CT33_Ampsuint16430267IntegerCT33_Amps
130Holding_Register420017CT33_kWuint16430269IntegerCT33_kW
131Holding_Register420853CT33_kWHuint32430271FloatCT33_kWH
132Holding_Register420714CT34_Ampsuint16430275IntegerCT34_Amps
133Holding_Register420058CT34_kWuint16430277IntegerCT34_kW
134Holding_Register420937CT34_kWHuint32430279FloatCT34_kWH
135Holding_Register420674CT35_Ampsuint16430283IntegerCT35_Amps
136Holding_Register420018CT35_kWuint16430285IntegerCT35_kW
137Holding_Register420855CT35_kWHuint32430287FloatCT35_kWH
138Holding_Register420715CT36_Ampsuint16430291IntegerCT36_Amps
139Holding_Register420059CT36_kWuint16430293IntegerCT36_kW
140Holding_Register420939CT36_kWHuint32430295FloatCT36_kWH
141Holding_Register420675CT37_Ampsuint16430299IntegerCT37_Amps
142Holding_Register420019CT37_kWuint16430301IntegerCT37_kW
143Holding_Register420857CT37_kWHuint32430303FloatCT37_kWH
144Holding_Register420716CT38_Ampsuint16430307IntegerCT38_Amps
145Holding_Register420060CT38_kWuint16430309IntegerCT38_kW
146Holding_Register420941CT38_kWHuint32430311FloatCT38_kWH
147Holding_Register420676CT39_Ampsuint16430315IntegerCT39_Amps
148Holding_Register420020CT39_kWuint16430317IntegerCT39_kW
149Holding_Register420859CT39_kWHuint32430319FloatCT39_kWH
150Holding_Register420717CT40_Ampsuint16430323IntegerCT40_Amps
151Holding_Register420061CT40_kWuint16430325IntegerCT40_kW
152Holding_Register420943CT40_kWHuint32430327FloatCT40_kWH
153Holding_Register420677CT41_Ampsuint16430331IntegerCT41_Amps
154Holding_Register420021CT41_kWuint16430333IntegerCT41_kW
155Holding_Register420861CT41_kWHuint32430335FloatCT41_kWH
156Holding_Register420718CT42_Ampsuint16430339IntegerCT42_Amps
157Holding_Register420062CT42_kWuint16430341IntegerCT42_kW
158Holding_Register420945CT42_kWHuint32430343FloatCT42_kWH
159Holding_Register420739CT43_Ampsuint16430347IntegerCT43_Amps
160Holding_Register420083CT43_kWuint16430349IntegerCT43_kW
161Holding_Register420985CT43_kWHuint32430351FloatCT43_kWH
162Holding_Register420780CT44_Ampsuint16430355IntegerCT44_Amps
163Holding_Register420124CT44_kWuint16430357IntegerCT44_kW
164Holding_Register421067CT44_kWHuint32430359FloatCT44_kWH
165Holding_Register420740CT45_Ampsuint16430363IntegerCT45_Amps
166Holding_Register420084CT45_kWuint16430365IntegerCT45_kW
167Holding_Register420987CT45_kWHuint32430367FloatCT45_kWH
168Holding_Register420781CT46_Ampsuint16430371IntegerCT46_Amps
169Holding_Register420125CT46_kWuint16430373IntegerCT46_kW
170Holding_Register421069CT46_kWHuint32430375FloatCT46_kWH
171Holding_Register420741CT47_Ampsuint16430379IntegerCT47_Amps
172Holding_Register420085CT47_kWuint16430381IntegerCT47_kW
173Holding_Register420989CT47_kWHuint32430383FloatCT47_kWH
174Holding_Register420782CT48_Ampsuint16430387IntegerCT48_Amps
175Holding_Register420126CT48_kWuint16430389IntegerCT48_kW
176Holding_Register421071CT48_kWHuint32430391FloatCT48_kWH
177Holding_Register420742CT49_Ampsuint16430395IntegerCT49_Amps
178Holding_Register420086CT49_kWuint16430397IntegerCT49_kW
179Holding_Register420991CT49_kWHuint32430399FloatCT49_kWH
180Holding_Register420783CT50_Ampsuint16430403IntegerCT50_Amps
181Holding_Register420127CT50_kWuint16430405IntegerCT50_kW
182Holding_Register421073CT50_kWHuint32430407FloatCT50_kWH
183Holding_Register420743CT51_Ampsuint16430411IntegerCT51_Amps
184Holding_Register420087CT51_kWuint16430413IntegerCT51_kW
185Holding_Register420993CT51_kWHuint32430415FloatCT51_kWH
186Holding_Register420784CT52_Ampsuint16430419IntegerCT52_Amps
187Holding_Register420128CT52_kWuint16430421IntegerCT52_kW
188Holding_Register421075CT52_kWHuint32430423FloatCT52_kWH
189Holding_Register420744CT53_Ampsuint16430427IntegerCT53_Amps
190Holding_Register420088CT53_kWuint16430429IntegerCT53_kW
191Holding_Register420995CT53_kWHuint32430431FloatCT53_kWH
192Holding_Register420785CT54_Ampsuint16430435IntegerCT54_Amps
193Holding_Register420129CT54_kWuint16430437IntegerCT54_kW
194Holding_Register421077CT54_kWHuint32430439FloatCT54_kWH
195Holding_Register420745CT55_Ampsuint16430443IntegerCT55_Amps
196Holding_Register420089CT55_kWuint16430445IntegerCT55_kW
197Holding_Register420997CT55_kWHuint32430447FloatCT55_kWH
198Holding_Register420786CT56_Ampsuint16430451IntegerCT56_Amps
199Holding_Register420130CT56_kWuint16430453IntegerCT56_kW
200Holding_Register421079CT56_kWHuint32430455FloatCT56_kWH
201Holding_Register420746CT57_Ampsuint16430459IntegerCT57_Amps
202Holding_Register420090CT57_kWuint16430461IntegerCT57_kW
203Holding_Register420999CT57_kWHuint32430463FloatCT57_kWH
204Holding_Register420787CT58_Ampsuint16430467IntegerCT58_Amps
205Holding_Register420131CT58_kWuint16430469IntegerCT58_kW
206Holding_Register421081CT58_kWHuint32430471FloatCT58_kWH
207Holding_Register420747CT59_Ampsuint16430475IntegerCT59_Amps
208Holding_Register420091CT59_kWuint16430477IntegerCT59_kW
209Holding_Register421001CT59_kWHuint32430479FloatCT59_kWH
210Holding_Register420788CT60_Ampsuint16430483IntegerCT60_Amps
211Holding_Register420132CT60_kWuint16430485IntegerCT60_kW
212Holding_Register421083CT60_kWHuint32430487FloatCT60_kWH
213Holding_Register420748CT61_Ampsuint16430491IntegerCT61_Amps
214Holding_Register420092CT61_kWuint16430493IntegerCT61_kW
215Holding_Register421003CT61_kWHuint32430495FloatCT61_kWH
216Holding_Register420789CT62_Ampsuint16430499IntegerCT62_Amps
217Holding_Register420133CT62_kWuint16430501IntegerCT62_kW
218Holding_Register421085CT62_kWHuint32430503FloatCT62_kWH
219Holding_Register420749CT63_Ampsuint16430507IntegerCT63_Amps
220Holding_Register420093CT63_kWuint16430509IntegerCT63_kW
221Holding_Register421005CT63_kWHuint32430511FloatCT63_kWH
222Holding_Register420790CT64_Ampsuint16430515IntegerCT64_Amps
223Holding_Register420134CT64_kWuint16430517IntegerCT64_kW
224Holding_Register421087CT64_kWHuint32430519FloatCT64_kWH
225Holding_Register420750CT65_Ampsuint16430523IntegerCT65_Amps
226Holding_Register420094CT65_kWuint16430525IntegerCT65_kW
227Holding_Register421007CT65_kWHuint32430527FloatCT65_kWH
228Holding_Register420791CT66_Ampsuint16430531IntegerCT66_Amps
229Holding_Register420135CT66_kWuint16430533IntegerCT66_kW
230Holding_Register421089CT66_kWHuint32430535FloatCT66_kWH
231Holding_Register420751CT67_Ampsuint16430539IntegerCT67_Amps
232Holding_Register420095CT67_kWuint16430541IntegerCT67_kW
233Holding_Register421009CT67_kWHuint32430543FloatCT67_kWH
234Holding_Register420792CT68_Ampsuint16430547IntegerCT68_Amps
235Holding_Register420136CT68_kWuint16430549IntegerCT68_kW
236Holding_Register421091CT68_kWHuint32430551FloatCT68_kWH
237Holding_Register420752CT69_Ampsuint16430555IntegerCT69_Amps
238Holding_Register420096CT69_kWuint16430557IntegerCT69_kW
239Holding_Register421011CT69_kWHuint32430559FloatCT69_kWH
240Holding_Register420793CT70_Ampsuint16430563IntegerCT70_Amps
241Holding_Register420137CT70_kWuint16430565IntegerCT70_kW
242Holding_Register421093CT70_kWHuint32430567FloatCT70_kWH
243Holding_Register420753CT71_Ampsuint16430571IntegerCT71_Amps
244Holding_Register420097CT71_kWuint16430573IntegerCT71_kW
245Holding_Register421013CT71_kWHuint32430575FloatCT71_kWH
246Holding_Register420794CT72_Ampsuint16430579IntegerCT72_Amps
247Holding_Register420138CT72_kWuint16430581IntegerCT72_kW
248Holding_Register421095CT72_kWHuint32430583FloatCT72_kWH
249Holding_Register420754CT73_Ampsuint16430587IntegerCT73_Amps
250Holding_Register420098CT73_kWuint16430589IntegerCT73_kW
251Holding_Register421015CT73_kWHuint32430591FloatCT73_kWH
252Holding_Register420795CT74_Ampsuint16430595IntegerCT74_Amps
253Holding_Register420139CT74_kWuint16430597IntegerCT74_kW
254Holding_Register421097CT74_kWHuint32430599FloatCT74_kWH
255Holding_Register420755CT75_Ampsuint16430603IntegerCT75_Amps
256Holding_Register420099CT75_kWuint16430605IntegerCT75_kW
257Holding_Register421017CT75_kWHuint32430607FloatCT75_kWH
258Holding_Register420796CT76_Ampsuint16430611IntegerCT76_Amps
259Holding_Register420140CT76_kWuint16430613IntegerCT76_kW
260Holding_Register421099CT76_kWHuint32430615FloatCT76_kWH
261Holding_Register420756CT77_Ampsuint16430619IntegerCT77_Amps
262Holding_Register420100CT77_kWuint16430621IntegerCT77_kW
263Holding_Register421019CT77_kWHuint32430623FloatCT77_kWH
264Holding_Register420797CT78_Ampsuint16430627IntegerCT78_Amps
265Holding_Register420141CT78_kWuint16430629IntegerCT78_kW
266Holding_Register421101CT78_kWHuint32430631FloatCT78_kWH
267Holding_Register420757CT79_Ampsuint16430635IntegerCT79_Amps
268Holding_Register420101CT79_kWuint16430637IntegerCT79_kW
269Holding_Register421021CT79_kWHuint32430639FloatCT79_kWH
270Holding_Register420798CT80_Ampsuint16430643IntegerCT80_Amps
271Holding_Register420142CT80_kWuint16430645IntegerCT80_kW
272Holding_Register421103CT80_kWHuint32430647FloatCT80_kWH
273Holding_Register420758CT81_Ampsuint16430651IntegerCT81_Amps
274Holding_Register420102CT81_kWuint16430653IntegerCT81_kW
275Holding_Register421023CT81_kWHuint32430655FloatCT81_kWH
276Holding_Register420799CT82_Ampsuint16430659IntegerCT82_Amps
277Holding_Register420143CT82_kWuint16430661IntegerCT82_kW
278Holding_Register421105CT82_kWHuint32430663FloatCT82_kWH
279Holding_Register420759CT83_Ampsuint16430667IntegerCT83_Amps
280Holding_Register420103CT83_kWuint16430669IntegerCT83_kW
281Holding_Register421025CT83_kWHuint32430671FloatCT83_kWH
282Holding_Register420800CT84_Ampsuint16430675IntegerCT84_Amps
283Holding_Register420144CT84_kWuint16430677IntegerCT84_kW
284Holding_Register421107CT84_kWHuint32430679FloatCT84_kWH
285
286Holding_Register422060Freqfloat430683FloatFreq
287Holding_Register41127kVAuint16430687IntegerkVA
288Holding_Register41119kWuint16430689IntegerkW
289Holding_Register41151kWHuint32430691FloatkWH
290Holding_Register41131PFuint16430695IntegerPF
291Holding_Register41102Volts_ABuint16430697IntegerVolts_AB
292Holding_Register41106Volts_ANuint16430699IntegerVolts_AN
293Holding_Register41103Volts_BCuint16430701IntegerVolts_BC
294Holding_Register41107Volts_BNuint16430703IntegerVolts_BN
295Holding_Register41104Volts_CAuint16430705IntegerVolts_CA
296Holding_Register41108Volts_CNuint16430707IntegerVolts_CN
297Holding_Register41105Volts_LL_Avguint16430709IntegerVolts_LL_Avg
298Holding_Register41109Volts_LN_Avguint16430711IntegerVolts_LN_Avg