Merge pull request #25 from emmanuelsrlok/ecruz/ChillerUpdate

Chiller daiking return temp and flow switch added
This commit is contained in:
Emmanuel HC
2025-10-08 08:36:04 -05:00
committed by GitHub
4 changed files with 13 additions and 3 deletions

View File

@@ -15,6 +15,7 @@
#include "Strategies/Strategy_PID.h"
#include "Strategies/Strategy_Ramp.h"
#include "Strategies/Strategy_Totalizer.h"
#include "Strategies/Strategy_SingleValue.h"
#include "Equipment/Equipment.h"
#include "ModbusPoints/Modbus_Point.h"
#include "ModbusPoints/Modbus_FloatDecorator.h"
@@ -40,6 +41,7 @@ RunningState<ModbusRTU>::RunningState() {
addStrategy("Actual Capacity", new PIDStrategy("Active SP", 1000, "Supply Temp"));
addStrategy("Comp1 Percent RLA", new RampStrategy(0.0f, 5.0f, 1000));
addStrategy("Comp2 Percent RLA", new RampStrategy(0.0f, 5.0f, 1000));
addStrategy("Return Temp", new SingleValueStrategy(85,3.0f, 1000));
}
/**
@@ -70,7 +72,6 @@ State<ModbusRTU>* RunningState<ModbusRTU>::update(Equipment<ModbusRTU>* equipmen
static_cast<PIDStrategy*>(PID_Strat)->setLimits(0.0f, highCapacityLimit);
float currentSP = 50.0f; // Default value
int currentMode = getPointValue(equipment, "Chiller Mode Output");
// Determine the correct setpoint based on the current operating mode.
switch(currentMode){
case 1:
@@ -119,6 +120,8 @@ State<ModbusRTU>* RunningState<ModbusRTU>::update(Equipment<ModbusRTU>* equipmen
setPointValue(equipment, "Chiller Mode Output", 2.0f);
}
float SupplyTemp = getPointValue(equipment, "Supply Temp");
setPointValue(equipment, "Return Temp", SupplyTemp + 14.0f);
setPointValue(equipment, "Active SP", currentSP);
// Apply any strategies defined for the standby state
@@ -137,6 +140,8 @@ void RunningState<ModbusRTU>::enterState(Equipment<ModbusRTU>* equipment) {
Serial.println("Enter Running State...");
// You could also update a Modbus register to show the "standby" state
setPointValue(equipment, "Run Enabled", 1);
setPointValue(equipment, "Flow Switch", 1);
}
/**

View File

@@ -13,6 +13,7 @@
#include "ModbusPoints/Modbus_FloatDecorator.h"
#include "Equipment/Equipment.h"
#include "Strategies/Strategy_Ramp.h"
#include "Strategies/Strategy_SingleValue.h"
#include <vector>
#include <string>
@@ -33,6 +34,7 @@ template<>
StandbyState<ModbusRTU>::StandbyState() {
addStrategy("Comp1 Percent RLA", new RampStrategy(0,5,1000));
addStrategy("Comp2 Percent RLA", new RampStrategy(0,5,1000));
addStrategy("Return Temp", new SingleValueStrategy(85,3.0f, 1000));
}
/**
@@ -75,6 +77,7 @@ void StandbyState<ModbusRTU>::enterState(Equipment<ModbusRTU>* equipment) {
// Logic to run when the equipment enters this state
Serial.println("Enter Standby State...");
setPointValue(equipment, "Run Enabled", 0);
setPointValue(equipment, "Flow Switch", 0);
}
/**

View File

@@ -56,7 +56,9 @@ modbusMap mb_map[] =
{
{HR, 100, 0, "State Control"}, //Internal to control from Modscan
{HR, 101, 0, "Fault Code"},
{HR_FLOAT, 102, 0, "Supply Temp"},
{HR_FLOAT, 102, 0, "Supply Temp"},
{HR_FLOAT, 103, 0, "Return Temp"}, //+14
{HR_FLOAT, 104, 0, "Flow Switch"},
{HR, 0, 0, "Chiller Local-Network"},
{HR, 1, 0, "Chiller Enable Output"},
{HR, 2, 0, "Run Enabled"},

View File

@@ -41,7 +41,7 @@ RunningState<ModbusIP>::RunningState() {
addStrategy("Source 1 Volts AB", new SingleValueStrategy(0.0F, 0.0f, 1000));
addStrategy("Source 1 Volts BC", new SingleValueStrategy(0.0F, 0.0f, 1000));
addStrategy("Source 1 Volts CA", new SingleValueStrategy(0.0F, 0.0f, 1000));
addStrategy("Source 2 Volts CA", new SingleValueStrategy(0.0F, 0.0f, 1000));
addStrategy("Source 2 Volts AB", new SingleValueStrategy(480.0F, 2.0f, 1000));
addStrategy("Source 2 Volts BC", new SingleValueStrategy(480.0F, 2.0f, 1000));
addStrategy("Source 2 Volts CA", new SingleValueStrategy(480.0F, 2.0f, 1000));